Comparative analysis of visual quality between unilateral implantation of a trifocal intraocular lens and a rotationally asymmetric refractive multifocal intraocular lens

被引:3
|
作者
Hui, Na [1 ]
Chu, Mei-Fang [1 ]
Li, Yan [1 ]
Wang, Cong-Yi [1 ]
Yu, Lei [1 ]
Ma, Bo [1 ]
机构
[1] Xi An Jiao Tong Univ, Shaanxi Eye Hosp, Xian Peoples Hosp, Xian Hosp 4,Affiliated Guangren Hosp,Sch Med, Xian 710004, Shaanxi, Peoples R China
关键词
trifocal intraocular lens; rotationally asymmetric multifocal intraocular lens; visual quality; contrast sensitivity; BILATERAL IMPLANTATION; EXTENDED RANGE; PERFORMANCE; OUTCOMES; CATQUEST-9SF;
D O I
10.18240/ijo.2022.09.08
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
AIM: To compare visual quality after unilateral cataract surgery with implantation of trifocal intraocular lens (IOL) and asymmetric refractive multifocal IOL. METHODS: The prospective nonrandom, comparative study consisted of 60 eyes of 60 patients suffering unilateral cataract surgery with implantation of two different IOLs: AT LISA tri 839MP (30 eyes; Carl Zeiss Meditec, Germany) and LS-313 MF30 (30 eyes; Oculentis GmbH, Germany). Visual acuity, refractive outcome, contrast sensitivity, defocus curves, quality of vision, and optical phenomena were evaluated at 3mo postoperatively. RESULTS: There were no statistical differences between groups in uncorrected distance visual acuity (P=0.1 3) and uncorrected near visual acuity (P=0.54). In contrast, uncorrected intermediate visual acuity was better in trifocal group compared to the refractive multifocal group (P=0.02). No significant statistical between-group difference was detected in cylinder (P=0.43). Compared to trifocal group, spherical refraction and spherical equivalent in refractive multi focal group were more myopic (P < 0.01). Under photopic conditions, no significant statistical differences were found between groups in contrast sensitivity at 3 and 6 cycles per degree (cpd). The refractive multifocal group performed better at 12 and 18 cpd than the trifocal group (P=0.01, P=0.034, respectively). The questionnaires of quality of vision and optical phenomena showed no differences between groups. CONCLUSION: Trifocal IOL is superior to refractive multifocal IOL in intermediate visual acuity. Rotationally asymmetric refractive multifocal IOL is more myopic in automated refraction and significantly better for the photopic contrast sensitivity at high frequency.
引用
收藏
页码:1460 / 1467
页数:8
相关论文
共 50 条
  • [31] Unilateral Refractive Lens Exchange with a Multifocal Intraocular Lens in Emmetropic Presbyopic Patients
    Levinger, Eliya
    Levinger, Shmuel
    Mimouni, Michael
    Trivizki, Omer
    Levinger, Nadav
    Barequet, Irina S.
    Rabina, Gilad
    CURRENT EYE RESEARCH, 2019, 44 (07) : 726 - 732
  • [32] Optical bench performance of a novel trifocal intraocular lens compared with a multifocal intraocular lens
    Lee, Shinwook
    Choi, Myoung
    Xu, Zaiwei
    Zhao, Zeyu
    Alexander, Elsinore
    Liu, Yueai
    CLINICAL OPHTHALMOLOGY, 2016, 10 : 1031 - 1038
  • [33] Visual performance after the implantation of a new trifocal intraocular lens
    Vryghem, Jerome C.
    Heireman, Steven
    CLINICAL OPHTHALMOLOGY, 2013, 7 : 1957 - 1965
  • [34] Stereoacuity and aniseikonia after unilateral and bilateral implantation of the Array refractive multifocal intraocular lens
    Häring, G
    Gronemeyer, A
    Hedderich, J
    de Decker, W
    JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 1999, 25 (08): : 1151 - 1156
  • [35] Secondary positioning of rotationally asymmetric refractive multifocal intraocular lens in a patient with glaucoma: A case report
    Cong Fan
    Yi Zhou
    Jian Jiang
    World Journal of Clinical Cases, 2022, (20) : 7013 - 7019
  • [36] Secondary positioning of rotationally asymmetric refractive multifocal intraocular lens in a patient with glaucoma: A case report
    Fan, Cong
    Zhou, Yi
    Jiang, Jian
    WORLD JOURNAL OF CLINICAL CASES, 2022, 10 (20) : 7013 - 7019
  • [37] Optical Characterization of a Rotationally Asymmetric Refractive Multifocal Intraocular Lens Compared to a Standard Monofocal One
    Albarran-Diego, Cesar
    Garcia-Montero, Maria
    Garzon, Nuria
    Gomez-Pedrero, Jose Antonio
    APPLIED SCIENCES-BASEL, 2024, 14 (13):
  • [38] Tolerance to Residual Refractive Errors After Trifocal and Trifocal Toric Intraocular Lens Implantation
    Rementeria-Capelo, Laureano A.
    Contreras, Ines
    Garcia-Perez, Jorge L.
    Carrillo, Virginia
    Gros-Otero, Juan
    Ruiz-Alcocer, Javier
    EYE & CONTACT LENS-SCIENCE AND CLINICAL PRACTICE, 2021, 47 (04): : 213 - 218
  • [39] Comparison of visual performance and quality of life with a new nondiffractive EDOF intraocular lens and a trifocal intraocular lens
    Asena, Leyla
    Dogan, Irem Kirci
    Oto, Sibel
    Altinors, Dilek Dursun
    JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2023, 49 (05): : 504 - 511
  • [40] Refractive outcomes after bilateral multifocal intraocular lens implantation
    Pineda-Fernández, A
    Jaramillo, J
    Celis, V
    Vargas, J
    DiStacio, M
    Galíndez, A
    Del Valle, M
    JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2004, 30 (03): : 685 - 688