Comparative analysis of visual quality between unilateral implantation of a trifocal intraocular lens and a rotationally asymmetric refractive multifocal intraocular lens

被引:3
|
作者
Hui, Na [1 ]
Chu, Mei-Fang [1 ]
Li, Yan [1 ]
Wang, Cong-Yi [1 ]
Yu, Lei [1 ]
Ma, Bo [1 ]
机构
[1] Xi An Jiao Tong Univ, Shaanxi Eye Hosp, Xian Peoples Hosp, Xian Hosp 4,Affiliated Guangren Hosp,Sch Med, Xian 710004, Shaanxi, Peoples R China
关键词
trifocal intraocular lens; rotationally asymmetric multifocal intraocular lens; visual quality; contrast sensitivity; BILATERAL IMPLANTATION; EXTENDED RANGE; PERFORMANCE; OUTCOMES; CATQUEST-9SF;
D O I
10.18240/ijo.2022.09.08
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
AIM: To compare visual quality after unilateral cataract surgery with implantation of trifocal intraocular lens (IOL) and asymmetric refractive multifocal IOL. METHODS: The prospective nonrandom, comparative study consisted of 60 eyes of 60 patients suffering unilateral cataract surgery with implantation of two different IOLs: AT LISA tri 839MP (30 eyes; Carl Zeiss Meditec, Germany) and LS-313 MF30 (30 eyes; Oculentis GmbH, Germany). Visual acuity, refractive outcome, contrast sensitivity, defocus curves, quality of vision, and optical phenomena were evaluated at 3mo postoperatively. RESULTS: There were no statistical differences between groups in uncorrected distance visual acuity (P=0.1 3) and uncorrected near visual acuity (P=0.54). In contrast, uncorrected intermediate visual acuity was better in trifocal group compared to the refractive multifocal group (P=0.02). No significant statistical between-group difference was detected in cylinder (P=0.43). Compared to trifocal group, spherical refraction and spherical equivalent in refractive multi focal group were more myopic (P < 0.01). Under photopic conditions, no significant statistical differences were found between groups in contrast sensitivity at 3 and 6 cycles per degree (cpd). The refractive multifocal group performed better at 12 and 18 cpd than the trifocal group (P=0.01, P=0.034, respectively). The questionnaires of quality of vision and optical phenomena showed no differences between groups. CONCLUSION: Trifocal IOL is superior to refractive multifocal IOL in intermediate visual acuity. Rotationally asymmetric refractive multifocal IOL is more myopic in automated refraction and significantly better for the photopic contrast sensitivity at high frequency.
引用
收藏
页码:1460 / 1467
页数:8
相关论文
共 50 条
  • [1] Comparative analysis of visual quality between unilateral implantation of a trifocal intraocular lens and a rotationally asymmetric refractive multifocal intraocular lens
    Na Hui
    Mei-Fang Chu
    Yan Li
    Cong-Yi Wang
    Lei Yu
    Bo Ma
    International Journal of Ophthalmology, 2022, (09) : 1460 - 1467
  • [2] Comparative Analysis of Visual Performance and Optical Quality with a Rotationally Asymmetric Multifocal Intraocular Lens and an Apodized Diffractive Multifocal Intraocular Lens
    Wang, Xiao
    Tu, Haixia
    Wang, Yong
    JOURNAL OF OPHTHALMOLOGY, 2020, 2020
  • [3] Rotationally asymmetric multifocal intraocular lens
    Carifi, Gianluca
    JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2012, 38 (06): : 1116 - 1117
  • [4] A comparison of the visual performance of refractive rotationally asymmetric multifocal intraocular lenses and trifocal intraocular lenses
    Qiu, Jing-Jing
    Zhang, Qian
    Fu, Shu-Hua
    Huang, Jun-Qi
    Wang, Zhi-Hong
    You, Zhi-Peng
    Liu, Fei
    Sun, Tao
    MATERIALS EXPRESS, 2023, 13 (06) : 1110 - 1115
  • [5] Visual and refractive outcomes of opposite clear corneal incision combined with rotationally asymmetric multifocal intraocular lens implantation
    Qin, Xiaoyu
    Yao, Pengxiang
    Wu, Xinyuan
    Wu, Yang
    Hong, Yufang
    Chen, Zhenzong
    Yuan, Yuanzhi
    FRONTIERS IN MEDICINE, 2024, 11
  • [6] Initial Experience With a New Refractive Rotationally Asymmetric Multifocal Intraocular Lens
    Venter, Jan A.
    Barclay, Dean
    Pelouskova, Martina
    Bull, Claire E. L.
    JOURNAL OF REFRACTIVE SURGERY, 2014, 30 (11) : 770 - U100
  • [7] Rotationally asymmetric multifocal intraocular lens Reply
    van der Linden, Jan Willem
    van Velthoven, Mirjam
    van der Meulen, Ivanka
    Nieuwendaal, Carla
    Mourits, Maarten
    Lapid-Gortzak, Ruth
    JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2012, 38 (06): : 1117 - 1117
  • [8] Predictive factors for photic phenomena after refractive,rotationally asymmetric,multifocal intraocular lens implantation
    Hungwon Tchah
    Kiyeun Nam
    Aeri Yoo
    International Journal of Ophthalmology, 2017, 10 (02) : 241 - 245
  • [9] Predictive factors for photic phenomena after refractive, rotationally asymmetric, multifocal intraocular lens implantation
    Tchah, Hungwon
    Nam, Kiyeun
    Yoo, Aeri
    INTERNATIONAL JOURNAL OF OPHTHALMOLOGY, 2017, 10 (02) : 241 - 245
  • [10] Visual and refractive outcomes following implantation of a new trifocal intraocular lens
    Lawless, Michael
    Hodge, Chris
    Reich, Joe
    Levitz, Lewis
    Bhatt, Uday K.
    McAlinden, Colm
    Roberts, Kate
    Roberts, Timothy V.
    EYE AND VISION, 2017, 4