Lorentz force electrical impedance tomography using magnetic field measurements

被引:34
作者
Zengin, Reyhan [1 ,2 ]
Gencer, Nevzat Guneri [1 ]
机构
[1] Middle East Tech Univ, Dept Elect & Elect Engn, Ankara, Turkey
[2] Selcuk Univ, Dept Elect & Elect Engn, Konya, Turkey
关键词
electrical conductivity imaging; electrical impedance tomography; magneto-acousto-electrical tomography; Hall effect imaging; ultrasound; MAGNETOACOUSTIC TOMOGRAPHY; DIELECTRIC-PROPERTIES; BIOLOGICAL TISSUES; INDUCTION; MODELS;
D O I
10.1088/0031-9155/61/16/5887
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
In this study, magnetic field measurement technique is investigated to image the electrical conductivity properties of biological tissues using Lorentz forces. This technique is based on electrical current induction using ultrasound together with an applied static magnetic field. The magnetic field intensity generated due to induced currents is measured using two coil configurations, namely, a rectangular loop coil and a novel xy coil pair. A time-varying voltage is picked-up and recorded while the acoustic wave propagates along its path. The forward problem of this imaging modality is defined as calculation of the pick-up voltages due to a given acoustic excitation and known body properties. Firstly, the feasibility of the proposed technique is investigated analytically. The basic field equations governing the behaviour of time-varying electromagnetic fields are presented. Secondly, the general formulation of the partial differential equations for the scalar and magnetic vector potentials are derived. To investigate the feasibility of this technique, numerical studies are conducted using a finite element method based software. To sense the pick-up voltages a novel coil configuration (xy coil pairs) is proposed. Two-dimensional numerical geometry with a 16-element linear phased array (LPA) ultrasonic transducer (1 MHz) and a conductive body (breast fat) with five tumorous tissues is modeled. The static magnetic field is assumed to be 4 Tesla. To understand the performance of the imaging system, the sensitivity matrix is analyzed. The sensitivity matrix is obtained for two different locations of LPA transducer with eleven steering angles from -25 degrees to 25 degrees at intervals of 5 degrees. The characteristics of the imaging system are shown with the singular value decomposition (SVD) of the sensitivity matrix. The images are reconstructed with the truncated SVD algorithm. The signal-to-noise ratio in measurements is assumed 80 dB. Simulation studies based on the sensitivity matrix analysis reveal that perturbations with 5 mm x 5 mm size can be detected up to a 3.5 cm depth.
引用
收藏
页码:5887 / 5905
页数:19
相关论文
共 36 条
[1]   Mathematical models and reconstruction methods in magneto-acoustic imaging [J].
Ammari, Habib ;
Capdeboscq, Yves ;
Kang, Hyeonbae ;
Kozhemyak, Anastasia .
EUROPEAN JOURNAL OF APPLIED MATHEMATICS, 2009, 20 :303-317
[2]   APPLIED POTENTIAL TOMOGRAPHY [J].
BARBER, DC ;
BROWN, BH .
JOURNAL OF PHYSICS E-SCIENTIFIC INSTRUMENTS, 1984, 17 (09) :723-733
[3]   The effect of electrical anisotropy during magnetoacoustic tomography with magnetic induction [J].
Brinker, Kaytlin ;
Roth, Bradley J. .
IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 2008, 55 (05) :1637-1639
[4]   The dielectric properties of biological tissues .2. Measurements in the frequency range 10 Hz to 20 GHz [J].
Gabriel, S ;
Lau, RW ;
Gabriel, C .
PHYSICS IN MEDICINE AND BIOLOGY, 1996, 41 (11) :2251-2269
[5]   The dielectric properties of biological tissues .3. Parametric models for the dielectric spectrum of tissues [J].
Gabriel, S ;
Lau, RW ;
Gabriel, C .
PHYSICS IN MEDICINE AND BIOLOGY, 1996, 41 (11) :2271-2293
[6]  
Gencer N G, 2013, PCT Patent Application, Patent No. [P-13/344, 13344]
[7]  
Gencer N G, 1993, THESIS
[8]   ELECTRICAL-IMPEDANCE TOMOGRAPHY USING INDUCED CURRENTS [J].
GENCER, NG ;
KUZUOGLU, M ;
IDER, YZ .
IEEE TRANSACTIONS ON MEDICAL IMAGING, 1994, 13 (02) :338-350
[9]   Electrical conductivity imaging via contactless measurements [J].
Gençer, NG ;
Tek, MN .
IEEE TRANSACTIONS ON MEDICAL IMAGING, 1999, 18 (07) :617-627
[10]   Optimal reference electrode selection for electric source imaging [J].
Gencer, NG ;
Williamson, SJ ;
Gueziec, A ;
Hummel, R .
ELECTROENCEPHALOGRAPHY AND CLINICAL NEUROPHYSIOLOGY, 1996, 99 (02) :163-173