Refractive index measurement using an optical cavity based biosensor with a differential detection

被引:7
作者
Cho, SaiHim [1 ]
Brake, Joshua H. [2 ]
Joy, Cody [1 ]
Kim, Seunghyun [1 ]
机构
[1] LeTourneau Univ, Dept Engn, Longview, TX 75602 USA
[2] CALTECH, Dept Elect Engn, Pasadena, CA 91125 USA
来源
OPTICAL DIAGNOSTICS AND SENSING XV: TOWARD POINT-OF-CARE DIAGNOSTICS | 2015年 / 9332卷
关键词
point-of-care; biosensor; optical cavity; differential detection; referencing method; noise cancelation; refractive index;
D O I
10.1117/12.2079300
中图分类号
O43 [光学];
学科分类号
070207 ; 0803 ;
摘要
We proposed a low cost optical cavity based biosensor with a differential detection for point-of-care diagnosis. Two lasers at different wavelengths are used for the differential detection. This method enhances the sensitivity through higher responsivity and noise cancelation. To reduce noise further, especially due to the unstable low cost laser diode output, we employed a referencing method in which a reference pixel value in each CMOS image frame is subtracted from all other pixels. To validate the designed structure and demonstrate the sensitivity of it, we perform refractive index measurements of fluids with our design. In this presentation, we will discuss our design, simulation results, and measurement results.
引用
收藏
页数:4
相关论文
共 50 条
  • [21] Optical Detection of Motion of an Object with a Refractive Index Coinciding with the Refractive Index of the Surroundings
    N. N. Rozanov
    Optics and Spectroscopy, 2004, 96 : 938 - 939
  • [22] Measurement of refractive index variation by differential surface plasmon resonance technique
    Lee, Ju-Yi
    Gu, Wu-Sheng
    OPTICAL REVIEW, 2013, 20 (02) : 182 - 184
  • [23] Benefits of a Scaled Differential Calculation method for use in a Fabry-Perot based Optical Cavity Biosensor
    Joy, Cody
    Kim, Seunghyun
    PROCEEDINGS OF THE 2017 TEXAS SYMPOSIUM ON WIRELESS AND MICROWAVE CIRCUITS AND SYSTEMS (WMCS), 2017,
  • [24] Measurement of refractive index variation by differential surface plasmon resonance technique
    Ju-Yi Lee
    Wu-Sheng Gu
    Optical Review, 2013, 20 : 182 - 184
  • [25] Spatial refractive index measurement of porcine artery using differential phase OCT
    Kim, J
    Dave, DP
    Rylander, C
    Feldman, M
    Thomsen, S
    Milner, TE
    COHERENCE DOMAIN OPTICAL METHODS AND OPTICAL COHERENCE TOMOGRAPHY IN BIOMEDICINE VIII, 2004, 5316 : 167 - 171
  • [26] Optical detection of motion of an object with a refractive index coinciding with the refractive index of the surroundings
    Rozanov, NN
    OPTICS AND SPECTROSCOPY, 2004, 96 (06) : 938 - 939
  • [27] Sensitivity Measurement based on the Refractive Index Detection of Dual-Coated PCF SPR Sensor
    Kumar, S.
    Kumar, D.
    MAPAN-JOURNAL OF METROLOGY SOCIETY OF INDIA, 2022, 37 (02): : 435 - 441
  • [28] Refractive index measurement of the mouse crystalline lens using optical coherence tomography
    Chakraborty, Ranjay
    Lacy, Kip D.
    Tan, Christopher C.
    Park, Han Na
    Pardue, Machelle T.
    EXPERIMENTAL EYE RESEARCH, 2014, 125 : 62 - 70
  • [29] Measurement of temperature coefficient of liquid refractive index using optical fiber interference
    Li, Zuowei
    Zhang, Wei
    Pei, Li
    Gao, Shuqin
    Wu, Xiaoli
    Jiguang Jishu/Laser Technology, 1993, 17 (01): : 50 - 52
  • [30] Experiment study on measurement of the optical fiber refractive index based on digital holography
    Wang, Duocheng
    Chang, Zheng
    Huang, Sujuan
    HOLOGRAPHY, DIFFRACTIVE OPTICS, AND APPLICATIONS V, 2012, 8556