Refractive index measurement using an optical cavity based biosensor with a differential detection

被引:7
|
作者
Cho, SaiHim [1 ]
Brake, Joshua H. [2 ]
Joy, Cody [1 ]
Kim, Seunghyun [1 ]
机构
[1] LeTourneau Univ, Dept Engn, Longview, TX 75602 USA
[2] CALTECH, Dept Elect Engn, Pasadena, CA 91125 USA
来源
OPTICAL DIAGNOSTICS AND SENSING XV: TOWARD POINT-OF-CARE DIAGNOSTICS | 2015年 / 9332卷
关键词
point-of-care; biosensor; optical cavity; differential detection; referencing method; noise cancelation; refractive index;
D O I
10.1117/12.2079300
中图分类号
O43 [光学];
学科分类号
070207 ; 0803 ;
摘要
We proposed a low cost optical cavity based biosensor with a differential detection for point-of-care diagnosis. Two lasers at different wavelengths are used for the differential detection. This method enhances the sensitivity through higher responsivity and noise cancelation. To reduce noise further, especially due to the unstable low cost laser diode output, we employed a referencing method in which a reference pixel value in each CMOS image frame is subtracted from all other pixels. To validate the designed structure and demonstrate the sensitivity of it, we perform refractive index measurements of fluids with our design. In this presentation, we will discuss our design, simulation results, and measurement results.
引用
收藏
页数:4
相关论文
共 50 条
  • [1] Demonstration of an optical cavity sensor with a differential detection method by refractive index measurements
    Rho, DongGee
    Cho, SaiHim
    Joy, Cody
    Kim, Seunghyun
    2015 TEXAS SYMPOSIUM ON WIRELESS AND MICROWAVE CIRCUITS AND SYSTEMS (WMCS), 2015,
  • [2] Preliminary measurement results of biotinylated BSA detection of a low cost optical cavity based biosensor using differential detection
    Cowles, Peter
    Joy, Cody
    Bujana, Antonio
    Rho, DongGee
    Kim, Seunghyun
    FRONTIERS IN BIOLOGICAL DETECTION: FROM NANOSENSORS TO SYSTEMS VIII, 2016, 9725
  • [3] Optical Cavity-based Biosensor Utilizing Differential Detection
    Mounce, Christopher
    Kim, Seunghyun
    2012 IEEE PHOTONICS CONFERENCE (IPC), 2012, : 214 - 215
  • [4] An optical cavity based biosensor with chained differential detection to improve sensitivity and fabrication tolerance
    Brake, Joshua
    Kim, Seung
    OPTICAL DIAGNOSTICS AND SENSING XIV: TOWARD POINT-OF-CARE DIAGNOSTICS, 2014, 8951
  • [5] Spatial refractive index measurement of porcine artery using differential phase optical coherence microscopy
    Kim, Jeehyun
    Dave, Digant P.
    Rylander, Christopher G.
    Oh, Junghwan
    Milner, Thomas E.
    LASERS IN SURGERY AND MEDICINE, 2006, 38 (10) : 955 - 959
  • [6] REFRACTIVE INDEX BASED DETECTION WITH A HIGH SENSITIVITY BIOSENSOR ENHANCED BY GRAPHENE
    Erturan, Ahmet Murat
    Gultekin, Seyfettin Sinan
    KONYA JOURNAL OF ENGINEERING SCIENCES, 2024, 12 (03):
  • [7] Human Teeth Disease Detection Using Refractive Index Based Surface Plasmon Resonance Biosensor
    Alam, Mohammad Khursheed
    Dhasarathan, Vigneswaran
    Natesan, Ayyanar
    Nambi, Ramanujam
    Zaman, Mahmud Uz
    Ganji, Kiran Kumar
    Basri, Rehana
    Munisekhar, Manay Srinivas
    Nagarajappa, Anil Kumar
    Abutayyem, Huda
    COATINGS, 2022, 12 (10)
  • [8] A Plus Shaped Cavity in Optical Fiber Based Refractive Index Sensor
    Singh, Lokendra
    Agrawal, Niteshkumar
    Saha, Chinmoy
    Kaushik, Brajesh Kumar
    IEEE TRANSACTIONS ON NANOBIOSCIENCE, 2022, 21 (02) : 199 - 205
  • [9] Liquid Refractive Index Measurement Based on Inverse Raytracing Using an Optical Angle Sensor
    Ohtani, Kozo
    Baba, Mitsuru
    2019 12TH BIOMEDICAL ENGINEERING INTERNATIONAL CONFERENCE (BMEICON 2019), 2019,
  • [10] Refractive Index Measurement of Liquids Based on Microstructured Optical Fibers
    Silva, Susana
    Roriz, Paulo
    Frazao, Orlando
    PHOTONICS, 2014, 1 (04): : 516 - 529