Seismic Response Mitigation of Base-Isolated Buildings

被引:25
作者
Stanikzai, Mohammad Hamayoun [1 ]
Elias, Said [2 ]
Rupakhety, Rajesh [2 ]
机构
[1] Old Dominion Univ, Dept Civil & Environm Engn, Norfolk, VA 23529 USA
[2] Univ Iceland, Sch Engn & Nat Sci, Fac Civil & Environm Engn, Earthquake Engn Res Ctr, Austurvegur 2a, IS-800 Selfoss, Iceland
来源
APPLIED SCIENCES-BASEL | 2020年 / 10卷 / 04期
关键词
Base-Isolated Buildings; bearing displacement; STMD; MTMDs; d-MTMDs; incremental dynamic analysis; earthquake; TUNED-MASS DAMPERS; NONLINEAR STRUCTURES; HAZARD ANALYSIS; OPTIMUM DESIGN; VIBRATION; DISPLACEMENT; PARAMETERS; SYSTEM;
D O I
10.3390/app10041230
中图分类号
O6 [化学];
学科分类号
0703 ;
摘要
Earthquake response mitigation of a base-isolated (BI) building equipped with (i) a single tuned mass damper at the top of the building, (ii) multiple tuned mass dampers (MTMDs) at the top of the building, and (iii) MTMDs distributed on different floors of the building (d-MTMDs) is studied. The shear-type buildings are modeled by considering only one lateral degree of freedom (DOF) at the floor level. Numerical approach of Newmark's integration is adopted for solving the coupled, governing differential equations of motion of 5- and 10-story BI buildings with and without TMD schemes. A set of 40 earthquake ground motions, scaled 80 times to get 3200 ground motions, is used to develop simplified fragility curves in terms of the isolator maximum displacement. Incremental dynamic analysis (IDA) is used to develop simplified fragility curves for the maximum target isolator displacement. It is found that TMDs are efficient in reducing the bearing displacement, top floor acceleration, and base shear of the BI buildings. In addition, it was noticed that TMDs are efficient in reducing the probability of failure of BI building. Further, it is found that the MTMDs placed at the top floor and d-MTMDs on different floors of BI buildings are more efficient in decreasing the probability of failure of the BI building when compared with STMD.
引用
收藏
页数:17
相关论文
共 46 条
[1]  
[Anonymous], FEMA350 SAC
[2]  
[Anonymous], FEMA351 SAC
[3]  
[Anonymous], 1997, Report No. SAC/BD-97/04
[4]  
[Anonymous], 2019, SUSTAINABILITY-BASEL
[5]   SEISMIC HAZARD ANALYSIS OF NONLINEAR STRUCTURES .2. APPLICATIONS [J].
BAZZURRO, P ;
CORNELL, CA .
JOURNAL OF STRUCTURAL ENGINEERING-ASCE, 1994, 120 (11) :3345-3365
[6]   SEISMIC HAZARD ANALYSIS OF NONLINEAR STRUCTURES .1. METHODOLOGY [J].
BAZZURRO, P ;
CORNELL, CA .
JOURNAL OF STRUCTURAL ENGINEERING-ASCE, 1994, 120 (11) :3320-3344
[7]  
Bertero V.V., 1977, Struct. Eng. Mech., V53, P29
[8]   Assessment of proposed lateral load patterns in pushover analysis for base isolated frames [J].
Bhandari, M. ;
Bharti, S. D. ;
Shrimali, M. K. ;
Datta, T. K. .
ENGINEERING STRUCTURES, 2018, 175 :531-548
[9]   Tuned tandem mass dampers-inerters with broadband high effectiveness for structures under white noise base excitations [J].
Cao, Liyuan ;
Li, Chunxiang .
STRUCTURAL CONTROL & HEALTH MONITORING, 2019, 26 (04)
[10]   Novel fluid inerter based tuned mass dampers for optimised structural control of base-isolated buildings [J].
De Domenico, Dario ;
Deastra, Predaricka ;
Ricciardi, Giuseppe ;
Sims, Neil D. ;
Wagg, David J. .
JOURNAL OF THE FRANKLIN INSTITUTE-ENGINEERING AND APPLIED MATHEMATICS, 2019, 356 (14) :7626-7649