Peri-implant assessment via cone beam computed tomography and digital periapical radiography: an ex vivo study

被引:6
作者
Silveira-Neto, Nicolau [1 ]
Flores, Mateus Ericson [1 ]
De Carli, Joao Paulo [1 ]
Costa, Max Doria [2 ]
Matos, Felipe de Souza [3 ]
Paranhos, Luiz Renato [4 ]
Sandini Linden, Maria Salete [1 ]
机构
[1] Univ Passo Fundo, Dept Odontol, Passo Fundo, RS, Brazil
[2] Univ Tiradentes, Dept Odontol, Aracaju, SE, Brazil
[3] Univ Estadual Paulista, Inst Ciencia & Tecnol, Dept Odontol Restauradora, Sao Jose Dos Campos, Brazil
[4] Univ Fed Sergipe, Dept Odontol, Lagarto, SE, Brazil
关键词
Artifacts; Cone Beam Computed Tomography; Dental Implants; ACCURACY;
D O I
10.6061/clinics/2017(11)10
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
OBJECTIVES: This research evaluated detail registration in peri-implant bone using two different cone beam computer tomography systems and a digital periapical radiograph. METHODS: Three different image acquisition protocols were established for each cone beam computer tomography apparatus, and three clinical situations were simulated in an ex vivo fresh pig mandible: buccal bone defect, peri-implant bone defect, and bone contact. Data were subjected to two analyses: quantitative and qualitative. The quantitative analyses involved a comparison of real specimen measures using a digital caliper in three regions of the preserved buccal bone - A, B and E (control group) - to cone beam computer tomography images obtained with different protocols (kp1, kp2, kp3, ip1, ip2, and ip3). In the qualitative analyses, the ability to register peri-implant details via tomography and digital periapical radiography was verified, as indicated by twelve evaluators. Data were analyzed with ANOVA and Tukey's test (alpha=0.05). RESULTS: The quantitative assessment showed means statistically equal to those of the control group under the following conditions: buccal bone defect B and E with kp1 and ip1, peri-implant bone defect E with kp2 and kp3, and bone contact A with kp1, kp2, kp3, and ip2. Qualitatively, only bone contacts were significantly different among the assessments, and the p3 results differed from the p1 and p2 results. The other results were statistically equivalent. CONCLUSIONS: The registration of peri-implant details was influenced by the image acquisition protocol, although metal artifacts were produced in all situations. The evaluators preferred the Kodak 9000 3D cone beam computer tomography in most cases. The evaluators identified buccal bone defects better with cone beam computer tomography and identified peri-implant bone defects better with digital periapical radiography.
引用
收藏
页码:708 / 713
页数:6
相关论文
共 50 条
[41]   Ability of Cone-beam Computed Tomography to Detect Periapical Lesions That Were Not Detected by Periapical Radiography: A Retrospective Assessment According to Tooth Group [J].
Uraba, Shintaro ;
Ebihara, Arata ;
Komatsu, Kei ;
Ohbayashi, Naoto ;
Okiji, Takashi .
JOURNAL OF ENDODONTICS, 2016, 42 (08) :1186-1190
[42]   Efficacy of cone-beam computed tomography with modified gray-scale range versus digital periapical radiography for the assessment of bone-implant interface gaps [J].
Kajan, Zahra Dalili ;
Abbasi, Sara ;
Khosravifard, Negar ;
Sigaroudi, Ali Khalighi ;
Motevasseli, Safa .
ORAL RADIOLOGY, 2022, 38 (01) :80-88
[43]   Effect of Cone-Beam Computed Tomography Field of View and Acquisition Frame on the Detection of Chemically Simulated Peri-Implant Bone Loss In Vitro [J].
Pinheiro, Lucas Rodrigues ;
Scarfe, William C. ;
de Oliveira Sales, Marcelo Augusto ;
Gaia, Bruno Felipe ;
Gonzalez Cortes, Arthur Rodriguez ;
Cavalcanti, Marcelo Gusmao .
JOURNAL OF PERIODONTOLOGY, 2015, 86 (10) :1159-1165
[44]   Evaluation of peri-implant bone defects on cone-beam computed tomography and the diagnostic accuracy of detecting these defects on panoramic images [J].
Oshima, Takayuki ;
Asaumi, Rieko ;
Ogura, Shin ;
Kawai, Taisuke .
IMAGING SCIENCE IN DENTISTRY, 2024, 54 (02) :171-180
[45]   Efficacy of a cone beam computed tomography metal artifact reduction algorithm for the detection of peri-implant fenestrations and dehiscences [J].
Lins de-Azevedo-Vaz, Sergio ;
Peyneau, Priscila Dias ;
Ramirez-Sotelo, Laura Ricardina ;
Vasconcelos, Karla de Faria ;
Flores Campos, Paulo Sergio ;
Haiter-Neto, Francisco .
ORAL SURGERY ORAL MEDICINE ORAL PATHOLOGY ORAL RADIOLOGY, 2016, 121 (05) :550-556
[46]   Mandibular Bone Structure Analysis Using Cone Beam Computed Tomography vs Primary Implant Stability: An Ex Vivo Study [J].
Pauwels, Ruben ;
Sessirisombat, Somchai ;
Panmekiate, Soontra .
INTERNATIONAL JOURNAL OF ORAL & MAXILLOFACIAL IMPLANTS, 2017, 32 (06) :1257-+
[47]   Measuring peri-implant bone lesions using low-dose cone-beam computed tomography [J].
Leisner, Laura Christine ;
Tasaka, Akinori ;
Trebing, Charlotte Theresa ;
Hilgenfeld, Tim ;
Kosinski, Matthias Adalbert ;
Kronsteiner, Dorothea ;
Rammelsberg, Peter ;
Schwindling, Franz Sebastian .
JOURNAL OF PROSTHODONTIC RESEARCH, 2022, 66 (02) :326-332
[48]   Efficacy of low-dose cone beam computed tomography and metal artifact reduction tool for assessment of peri-implant bone defects: an in vitro study [J].
Alaa Shafiek Nomier ;
Yousria Salah El-Din Gaweesh ;
Maha R. Taalab ;
Shaimaa Abu El Sadat .
BMC Oral Health, 22
[49]   Periapical radiography and cone beam computed tomography for assessment of the periapical bone defect 1 week and 12 months after root-end resection [J].
Christiansen, R. ;
Kirkevang, L-L ;
Gotfredsen, E. ;
Wenzel, A. .
DENTOMAXILLOFACIAL RADIOLOGY, 2009, 38 (08) :531-536
[50]   Accuracy of cone beam computed tomography and panoramic and periapical radiography for detection of apical periodontitis [J].
Estrela, Carlos ;
Bueno, Mike Reis ;
Leles, Claudio Rodrigues ;
Azevedo, Bruno ;
Azevedo, Jose Ribamar .
JOURNAL OF ENDODONTICS, 2008, 34 (03) :273-279