Peri-implant assessment via cone beam computed tomography and digital periapical radiography: an ex vivo study

被引:6
作者
Silveira-Neto, Nicolau [1 ]
Flores, Mateus Ericson [1 ]
De Carli, Joao Paulo [1 ]
Costa, Max Doria [2 ]
Matos, Felipe de Souza [3 ]
Paranhos, Luiz Renato [4 ]
Sandini Linden, Maria Salete [1 ]
机构
[1] Univ Passo Fundo, Dept Odontol, Passo Fundo, RS, Brazil
[2] Univ Tiradentes, Dept Odontol, Aracaju, SE, Brazil
[3] Univ Estadual Paulista, Inst Ciencia & Tecnol, Dept Odontol Restauradora, Sao Jose Dos Campos, Brazil
[4] Univ Fed Sergipe, Dept Odontol, Lagarto, SE, Brazil
关键词
Artifacts; Cone Beam Computed Tomography; Dental Implants; ACCURACY;
D O I
10.6061/clinics/2017(11)10
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
OBJECTIVES: This research evaluated detail registration in peri-implant bone using two different cone beam computer tomography systems and a digital periapical radiograph. METHODS: Three different image acquisition protocols were established for each cone beam computer tomography apparatus, and three clinical situations were simulated in an ex vivo fresh pig mandible: buccal bone defect, peri-implant bone defect, and bone contact. Data were subjected to two analyses: quantitative and qualitative. The quantitative analyses involved a comparison of real specimen measures using a digital caliper in three regions of the preserved buccal bone - A, B and E (control group) - to cone beam computer tomography images obtained with different protocols (kp1, kp2, kp3, ip1, ip2, and ip3). In the qualitative analyses, the ability to register peri-implant details via tomography and digital periapical radiography was verified, as indicated by twelve evaluators. Data were analyzed with ANOVA and Tukey's test (alpha=0.05). RESULTS: The quantitative assessment showed means statistically equal to those of the control group under the following conditions: buccal bone defect B and E with kp1 and ip1, peri-implant bone defect E with kp2 and kp3, and bone contact A with kp1, kp2, kp3, and ip2. Qualitatively, only bone contacts were significantly different among the assessments, and the p3 results differed from the p1 and p2 results. The other results were statistically equivalent. CONCLUSIONS: The registration of peri-implant details was influenced by the image acquisition protocol, although metal artifacts were produced in all situations. The evaluators preferred the Kodak 9000 3D cone beam computer tomography in most cases. The evaluators identified buccal bone defects better with cone beam computer tomography and identified peri-implant bone defects better with digital periapical radiography.
引用
收藏
页码:708 / 713
页数:6
相关论文
共 50 条
[21]   Efficacy of low-dose cone beam computed tomography and metal artifact reduction tool for assessment of peri-implant bone defects: an in vitro study [J].
Nomier, Alaa Shafiek ;
Gaweesh, Yousria Salah El-Din ;
Taalab, Maha R. R. ;
El Sadat, Shaimaa Abu .
BMC ORAL HEALTH, 2022, 22 (01)
[22]   Comparing the In Vivo Diagnostic Accuracy of Digital Periapical Radiography with Cone-beam Computed Tomography for the Detection of Vertical Root Fracture [J].
Chavda, Rajesh ;
Mannocci, Francesco ;
Andiappan, Manoharan ;
Patel, Shanon .
JOURNAL OF ENDODONTICS, 2014, 40 (10) :1524-1529
[23]   Measurement of Peri-Implant Bone Width with and without Metal Artifact Reduction Algorithm Using Two Cone-Beam Computed Tomography Software Programs [J].
Hedayatipanah, Morad ;
Salemi, Fatemeh ;
Kamyari, Naser ;
Yalpanian, Ashkan .
PESQUISA BRASILEIRA EM ODONTOPEDIATRIA E CLINICA INTEGRADA, 2021, 21
[24]   Accuracy of digital periapical radiography and cone-beam computed tomography in detecting external root resorption [J].
Creanga, Adriana Gabriela ;
Geha, Hassem ;
Sankar, Vidya ;
Teixeira, Fabricio B. ;
McMahan, Clyde Alex ;
Noujeim, Marcel .
IMAGING SCIENCE IN DENTISTRY, 2015, 45 (03) :153-158
[25]   Accuracy of Cone-Beam Computed Tomography and Periapical Radiography in Detecting Small Periapical Lesions [J].
Tsai, Patrick ;
Torabinejad, Mahmoud ;
Rice, Dwight ;
Azevedo, Bruno .
JOURNAL OF ENDODONTICS, 2012, 38 (07) :965-970
[26]   A comparative study of cone-beam computed tomography and digital periapical radiography in detecting mandibular molars root perforations [J].
Haghanifar, Sina ;
Moudi, Ehsan ;
Mesgarani, Abbas ;
Bijani, Ali ;
Abbaszadeh, Naghi .
IMAGING SCIENCE IN DENTISTRY, 2014, 44 (02) :115-119
[27]   Efficacy of cone-beam computed tomography with modified gray-scale range versus digital periapical radiography for the assessment of bone–implant interface gaps [J].
Zahra Dalili Kajan ;
Sara Abbasi ;
Negar Khosravifard ;
Ali Khalighi Sigaroudi ;
Safa Motevasseli .
Oral Radiology, 2022, 38 :80-88
[28]   Effect of field of view in the detection of chemically created peri-implant bone defects in bovine ribs using cone beam computed tomography: an in vitro study [J].
Pinheiro, Lucas Rodrigues ;
Gaia, Bruno Felipe ;
Oliveira de Sales, Marcelo Augusto ;
Umetsubo, Otavio Shoiti ;
Santos, Oseas, Jr. ;
Paraiso Cavalcanti, Marcelo Gusmao .
ORAL SURGERY ORAL MEDICINE ORAL PATHOLOGY ORAL RADIOLOGY, 2015, 120 (01) :69-77
[29]   Prognosis of root canal treatment in teeth with preoperative apical periodontitis: a study with cone-beam computed tomography and digital periapical radiography [J].
Restrepo-Restrepo, F. A. ;
Canas-Jimenez, S. J. ;
Romero-Albarracin, R. D. ;
Villa-Machado, P. A. ;
Perez-Cano, M. I. ;
Tobon-Arroyave, S. I. .
INTERNATIONAL ENDODONTIC JOURNAL, 2019, 52 (11) :1533-1546
[30]   Zirconia implants interfere with the evaluation of peri-implant bone defects in cone beam computed tomography (CBCT) images even with artifact reduction, a pilot study [J].
Kuusisto, Niina ;
Abushahba, Faleh ;
Syrjanen, Stina ;
Huumonen, Sisko ;
Vallittu, Pekka ;
Narhi, Timo .
DENTOMAXILLOFACIAL RADIOLOGY, 2023, 52 (08)