UV-absorbance detector for HPLC based on a light-emitting diode

被引:36
作者
Schmid, Stefan [1 ]
Macka, Mirek [2 ]
Hauser, Peter C. [1 ]
机构
[1] Univ Basel, Dept Chem, CH-4056 Basel, Switzerland
[2] Dublin City Univ, Dept Chem Sci, Dublin 9, Ireland
关键词
D O I
10.1039/b715681b
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A flow-through optical absorption detector for HPLC was constructed using a novel deep-UV light-emitting diode as radiation source with a peak emission wavelength of 255 nm. For measuring the transmitted intensity (a property correlated to Transmittance) a special UV-sensitive photodiode was employed. Besides the power source, no optical or electronic components other than an inexpensive operational amplifier and a few passive components were necessary. The performance of the detector was tested with three substances, namely nitrobenzene, benzoic acid and methyl benzoate, which were separated by gradient elution using an acetonitrile/water mixture and tetrabutylammonium hydrogensulfate as pH-buffer. Calibration curves for concentrations between 1.6 mu g(.)mL(-1) and 400 mu g(.)mL(-1) (nitrobenzene) and 8 mu g(.)mL(-1) and 2.5 mg(.)mL(-1) (benzoic acid and methyl benzoate) were determined and coefficients of determination, r(2), of 0.9945, 0.9972 and 0.9996 were obtained for quadratic curve fits for the 3 compounds respectively. Relative standard deviations (n = 7) for peak areas were determined as 0.35% (nitrobenzene, 80 mu g(.)mL(-1)), 0.27% (benzoic acid, 400 mu g(.)mL(-1)) and 0.83% (methyl benzoate, 200 mu g(.)mL(-1)). The lower limits of detection were found to be 750 ng(.)mL(-1), 5.8 mu g(.)mL(-1) and 12 mu g(.)mL(-1) for nitrobenzene, benzoic acid and methyl benzoate respectively.
引用
收藏
页码:465 / 469
页数:5
相关论文
共 21 条
[1]   Low pressure ion chromatography with a low cost paired emitter-detector diode based detector for the determination of alkaline earth metals in water samples [J].
Barron, Leon ;
Nesterenko, Pavel N. ;
Diamond, Dermot ;
O'Toole, Martina ;
Lau, King Tong ;
Paull, Brett .
ANALYTICA CHIMICA ACTA, 2006, 577 (01) :32-37
[2]   SENSITIVE, INDIRECT PHOTOMETRIC DETECTOR FOR HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY USING A LIGHT-EMITTING DIODE [J].
BERTHOD, A ;
GLICK, M ;
WINEFORDNER, JD .
JOURNAL OF CHROMATOGRAPHY, 1990, 502 (02) :305-315
[3]  
BETTERIDGE D, 1978, ANALYST, V103, P897, DOI 10.1039/an9780300897
[4]   An affordable high-performance optical absorbance detector for capillary systems [J].
Boring, CB ;
Dasgupta, PK .
ANALYTICA CHIMICA ACTA, 1997, 342 (2-3) :123-132
[5]   Separation of Nile Blue-labelled fatty acids by CE with absorbance detection using a red light-emitting diode [J].
Breadmore, Michael C. ;
Henderson, Rowan D. ;
Fakhari, Ali Reza ;
Macka, Miroslav ;
Haddad, Paul R. .
ELECTROPHORESIS, 2007, 28 (08) :1252-1258
[6]   Capillary electrophoresis detector using a light emitting diode and optical fibres [J].
Butler, PAG ;
Mills, B ;
Hauser, PC .
ANALYST, 1997, 122 (09) :949-953
[7]   LIGHT-EMITTING DIODE BASED FLOW-THROUGH OPTICAL-ABSORPTION DETECTORS [J].
DASGUPTA, PK ;
BELLAMY, HS ;
LIU, HH ;
LOPEZ, JL ;
LOREE, EL ;
MORRIS, K ;
PETERSEN, K ;
MIR, KA .
TALANTA, 1993, 40 (01) :53-74
[8]   Light emitting diode-based detectors absorbance, fluorescence and spectroelectrochemical measurements in a planar flow-through cell [J].
Dasgupta, PK ;
Eom, IY ;
Morris, KJ ;
Li, JZ .
ANALYTICA CHIMICA ACTA, 2003, 500 (1-2) :337-364
[9]   LIGHT EMITTING DIODES AND PHOTOTRANSISTORS IN PHOTOMETRIC MODULES [J].
FLASCHKA, H ;
MCKEITHAN, C ;
BARNES, R .
ANALYTICAL LETTERS, 1973, 6 (07) :585-594
[10]   Capillary electrophoresis with a UV light-emitting diode source for chemical monitoring of native and derivatized fluorescent compounds [J].
Hapuarachchi, Suminda ;
Janaway, Gordon A. ;
Aspinwall, Craig A. .
ELECTROPHORESIS, 2006, 27 (20) :4052-4059