Quantitation of cyclosporin A in whole blood by liquid chromatography/stable isotope dilution electrospray ionization mass spectrometry

被引:13
|
作者
Magni, F
Pereira, S
Leoni, M
Grisenti, G
Kienle, MG
机构
[1] IRCCS San Raffaele, Lab Spettrometria Massa, I-20132 Milan, Italy
[2] Poll Ind Chim SPA, Milan, Italy
[3] Univ Milan, Dipartimento Med Sperimentale Ambientale & Biotec, Milan, Italy
来源
JOURNAL OF MASS SPECTROMETRY | 2001年 / 36卷 / 06期
基金
美国国家科学基金会;
关键词
cyclosporin A; stable labelled isotope; mass spectrometry;
D O I
10.1002/jms.169
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
Therapy with cyclosporin A (CsA) for immunosuppression after organ transplantation requires monitoring of its levels in blood owing to the narrow therapeutic index of the drug and to the high inter-individual variability of the drug absorption and metabolism. We describe the preparation of CsA labelled with stable isotopes (C-13 and H-2) with an isotopic enrichment of about 99% using labelled glucose and its use as internal standard for quantification of CsA blood levels by isotope dilution/electrospray ionization mass spectrometry. The method was found to be linear in the tested range (1-1000 ng) with and without the matrix. The accuracy of the bracketting calibration curves prepared using 100 ng ml(-1) labelled CsA was within +/-1.7% (bias). The results confirmed the usefulness of the procedure as a reference method for the external quality assessment of the field methods for the evaluation of CsA blood concentration, the imprecision (relative standard deviation) and accuracy (bias) being <2%. Copyright (C) 2001 John Wiley & Sons, Ltd.
引用
收藏
页码:670 / 676
页数:7
相关论文
共 50 条
  • [41] Screening of dimethoate in food by isotope dilution and electrospray ionization tandem mass spectrometry
    Mazzotti, Fabio
    Di Donna, Leonardo
    Macchione, Barbara
    Maiuolo, Loredana
    Perri, Enzo
    Sindona, Giovanni
    RAPID COMMUNICATIONS IN MASS SPECTROMETRY, 2009, 23 (10) : 1515 - 1518
  • [42] Determination of acrylamide in infant cereal-based foods by isotope dilution liquid chromatography coupled with electrospray ionization tandem mass spectrometry
    Zhang, Y
    Jiao, JJ
    Ren, YP
    Wu, XQ
    Zhang, Y
    ANALYTICA CHIMICA ACTA, 2005, 551 (1-2) : 150 - 158
  • [43] Isotope dilution-liquid chromatography electrospray ionization-tandem mass spectrometry for the determination of serum thyroxine as a potential reference method
    De Brabandere, VI
    Hou, P
    Stockl, D
    Thienpont, LM
    De Leenheer, AP
    RAPID COMMUNICATIONS IN MASS SPECTROMETRY, 1998, 12 (16) : 1099 - 1103
  • [44] Determination of serum cortisol by isotope-dilution liquid-chromatography electrospray ionization tandem mass spectrometry with on-line extraction
    Vogeser, M
    Briegel, J
    Jacob, K
    CLINICAL CHEMISTRY AND LABORATORY MEDICINE, 2001, 39 (10) : 944 - 947
  • [45] Stable-Isotope Dilution HPLC-Electrospray Ionization Tandem Mass Spectrometry Method for Quantifying Hydroxyurea in Dried Blood Samples
    Marahatta, Anu
    Megaraj, Vandana
    McGann, Patrick T.
    Ware, Russell E.
    Setchell, Kenneth D. R.
    CLINICAL CHEMISTRY, 2016, 62 (12) : 1593 - 1601
  • [46] Modified method for determination of sulfur metabolites in plant tissues by stable isotope dilution-based liquid chromatography-electrospray ionization-tandem mass spectrometry
    Chang, Ya-Lan
    Hsieh, Chin-Lin
    Huang, Yao-Moan
    Chiou, Wen-Liang
    Kuo, Yueh-Hsiung
    Tseng, Mei-Hwei
    ANALYTICAL BIOCHEMISTRY, 2013, 442 (01) : 24 - 33
  • [47] Determination of digitoxin in human serum using stable isotope diluted liquid chromatography/electrospray ionization-tandem mass spectrometry
    Mitamura, K
    Horikawa, A
    Nagahama, A
    Shimada, K
    Fujii, Y
    JOURNAL OF LIQUID CHROMATOGRAPHY & RELATED TECHNOLOGIES, 2005, 28 (18) : 2839 - 2848
  • [48] Determination of bromadiolone in whole blood by high-performance liquid chromatography coupled with electrospray ionization tandem mass spectrometry
    Jin, Mi-Cong
    Ren, Yi-Ping
    Xu, Xiao-Min
    Chen, Xiao-Hong
    FORENSIC SCIENCE INTERNATIONAL, 2007, 171 (01) : 52 - 56
  • [49] Determination of metolazone in human blood by liquid chromatography with electrospray ionization tandem mass spectrometry
    Wei, Guangli
    Xiao, Shuhua
    Liu, Changxiao
    JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2007, 845 (01): : 169 - 173
  • [50] Quantitative measurement of salivary testosterone in Korean adults by stable isotope-dilution liquid chromatography-electrospray-tandem mass spectrometry
    Lee, Sanghoo
    Kwon, Soonho
    Shin, Hye-Jin
    Park, Jimyeong
    Lim, Hwan-Sub
    Lee, Kyoung-Ryul
    Kim, Young-Jin
    BMB REPORTS, 2010, 43 (11) : 761 - 765