Neutron-gamma mixed field measurements by means of MCP-TLD600 dosimeter pair

被引:32
作者
Triolo, A. [1 ]
Marrale, M. [1 ,2 ]
Brai, M. [1 ,2 ]
机构
[1] Univ Palermo, Dipartimento Fis & Technol Relative, I-90128 Palermo, Italy
[2] Ist Nazl Fis Nucl, Palermo & Gruppo V Sezione, Unita CNISM, Catania, Italy
关键词
thermoluminescence; TLD600; TLD700; MCP; thermal neutrons; neutron dosimetry;
D O I
10.1016/j.nimb.2007.08.009
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
In this paper, we compared the TL response of three types of thermoluminescence dosimeters, TLD600 ((LiF)-Li-6:Mg,Ti), TLD700 ((LiF)-Li-7:Mg,Ti) and MCP (LiF:Mg,Cu,P) after exposure to a n-gamma mixed field in the fluence range of radiotherapeutic applications. Since a dosimeter pair is required to discriminate the two components of the mixed field, we analyzed the ability of each dosimeter pair to provide the fluence value in the mixed field. At this aim we performed a Co-60-gamma calibration and a neutron calibration for all three dosimeter types. Finally, a blind test was performed in order to analyze the accuracy of each dosimeter pair and we found that in this mixed field the fluence value obtained through the TLD600-MCP pair is as accurate as the value obtained through the most common TLD600-TLD700 pair. (c) 2007 Elsevier B.V. All rights reserved.
引用
收藏
页码:183 / 188
页数:6
相关论文
共 23 条
[1]   THERMOLUMINESCENCE EFFICIENCY OF LIFMG,CU,P (MCP-N) DETECTORS TO PHOTONS, BETA-ELECTRONS, ALPHA-PARTICLES AND THERMAL-NEUTRONS [J].
BILSKI, P ;
OLKO, P ;
BURGKHARDT, B ;
PIESCH, E ;
WALIGORSKI, MPR .
RADIATION PROTECTION DOSIMETRY, 1994, 55 (01) :31-38
[3]  
FANG W, 1986, RADIAT PROT DOSIM, V17, P418
[4]   Dependence of TLD thermoluminescence yield on absorbed dose in a thermal neutron field [J].
Gambarini, G ;
Roy, MS .
APPLIED RADIATION AND ISOTOPES, 1997, 48 (10-12) :1467-1475
[5]   In-phantom imaging of all dose components in boron neutron capture therapy by means of gel dosimeters [J].
Gambarini, G ;
Colli, V ;
Gay, S ;
Petrovich, C ;
Pirola, L ;
Rosi, G .
APPLIED RADIATION AND ISOTOPES, 2004, 61 (05) :759-763
[6]   New horizons for therapy based on the boron neutron capture reaction [J].
Hawthorne, MF .
MOLECULAR MEDICINE TODAY, 1998, 4 (04) :174-181
[7]   Lithium carbonate (Li2CO3) as a material for thermal neutron fluence measurements [J].
Herrera, E ;
Ureña-Núñez, F ;
Loya, AD .
APPLIED RADIATION AND ISOTOPES, 2005, 63 (02) :241-246
[8]  
Horowitz Y, 1990, RADIAT PROT DOSIM, V30, P75
[9]  
*ICRU, 1977, 26 ICRU
[10]  
Locher GL, 1936, AM J ROENTGENOL RADI, V36, P1