Safety and efficacy of biodegradable polymer-coated thin strut sirolimus-eluting stent vs. durable polymer-coated everolimus-eluting stent in patients with acute myocardial infarction

被引:7
作者
Gasior, Pawel [1 ]
Gierlotka, Marek [2 ,3 ]
Szczurek-Katanski, Krzysztof [4 ]
Osuch, Marcin [4 ]
Roleder, Magda [1 ]
Hawranek, Michal [5 ,6 ]
Gasior, Mariusz [5 ,6 ]
Wojakowski, Wojciech [1 ]
Polonski, Lech [5 ,6 ]
机构
[1] Med Univ Silesia, Dept Cardiol & Struct Heart Dis, 45-47 Ziolowa St, PL-40635 Katowice, Poland
[2] Silesian Ctr Heart Dis, Dept Cardiol 3, Zabrze, Poland
[3] Univ Opole, Univ Hosp, Fac Nat Sci & Technol, Dept Cardiol, Opole, Poland
[4] Scanmed, Krakow, Poland
[5] Med Univ Silesia, Sch Med, Dept Cardiol 3, Div Dent Zabrze, Katowice, Poland
[6] Silesian Ctr Heart Dis, Zabrze, Poland
来源
POSTEPY W KARDIOLOGII INTERWENCYJNEJ | 2018年 / 14卷 / 04期
关键词
acute myocardial infarction; bioabsorbable polymer; drug-eluting stents; PERCUTANEOUS CORONARY INTERVENTION; BARE-METAL STENTS; RANDOMIZED CONTROLLED-TRIALS; DUAL ANTIPLATELET THERAPY; NETWORK METAANALYSIS; ARTERY-DISEASE; CLINICAL-OUTCOMES; POOLED ANALYSIS; THROMBOSIS; EVENTS;
D O I
10.5114/aic.2018.79194
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Introduction: The biodegradable polymer drug-eluting stents were developed to improve vascular healing. However, further data are needed to confirm the safety and efficacy of these stents in patients with acute myocardial infarction (AMI). Aim: We sought to determine the 1-year clinical follow-up in patients with AMI treated with a thin strut biodegradable polymer-coated sirolimus-eluting stent (BP-SES) versus a durable coating everolimus-eluting stent (DP-EES). Material and methods: We analyzed patients with AMI (STEMI and NSTEMI) treated with either a BP-SES (ALEX, Balton, Poland, n = 886) or DP-EES (XIENCE, Abbott, USA, n = 1054) with available 1-year clinical follow-up using propensity score matching. Outcomes included target vessel revascularization (TVR) as the efficacy outcome and all-cause death, myocardial infarction, and definite/probable stent thrombosis as safety outcomes. Results: After propensity score matching 672 patients treated with BP-SES and 672 patients treated with DP-EES were selected. Procedural and clinical characteristics were similar between the groups. In-hospital mortality was similar in both tested groups. One-year follow-up demonstrated comparable efficacy outcome TVR (BP-SES 7.1% vs. DP-EES 5.2%, p = 0.14), as well as similar safety outcomes of all-cause death, myocardial infarction, and definite/probable stent thrombosis. Conclusions: The thin-strut biodegradable polymer coated sirolimus-eluting stent demonstrated comparable clinical outcomes at 1 year after implantation to the DP-EES. These data support the relative safety and efficacy of BP-SES in AMI patients undergoing percutaneous coronary intervention.
引用
收藏
页码:347 / 355
页数:9
相关论文
共 39 条
[1]   Mechanisms, Pathophysiology, and Clinical Aspects of Incomplete Stent Apposition [J].
Attizzani, Guilherme F. ;
Capodanno, Davide ;
Ohno, Yohei ;
Tamburino, Corrado .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2014, 63 (14) :1355-1367
[2]   Bioabsorbable polymer everolimus-eluting stents in patients with acute myocardial infarction: a report from the Swedish Coronary Angiography and Angioplasty Registry [J].
Buccheri, Sergio ;
Sarno, Giovanna ;
Lagerqvist, Bo ;
Olivecrona, Goran ;
Hambraeus, Kristina ;
Witt, Nils ;
Lindholm, Daniel ;
Erlinge, David ;
Angeras, Oskar ;
James, Stefan .
EUROINTERVENTION, 2018, 14 (05) :562-569
[3]   Stent thrombosis late after implantation of first-generation drug-eluting stents - A cause for concern [J].
Camenzind, Edoardo ;
Steg, P. Gabriel ;
Wijns, William .
CIRCULATION, 2007, 115 (11) :1440-1455
[4]   Biolimus-eluting biodegradable polymer-coated stent versus durable polymer-coated sirolimus-eluting stent in unselected patients receiving percutaneous coronary intervention (SORT OUT V): a randomised non-inferiority trial [J].
Christiansen, Evald Hoj ;
Jensen, Lisette Okkels ;
Thayssen, Per ;
Tilsted, Hans-Henrik ;
Krusell, Lars Romer ;
Hansen, Knud Norregaard ;
Kaltoft, Anne ;
Maeng, Michael ;
Kristensen, Steen Dalby ;
Botker, Hans Erik ;
Terkelsen, Christian Juhl ;
Villadsen, Anton Boel ;
Ravkilde, Jan ;
Aaroe, Jens ;
Madsen, Morten ;
Thuesen, Leif ;
Lassen, Jens Flensted .
LANCET, 2013, 381 (9867) :661-669
[5]   Randomized, controlled trials, observational studies, and the hierarchy of research designs. [J].
Concato, J ;
Shah, N ;
Horwitz, RI .
NEW ENGLAND JOURNAL OF MEDICINE, 2000, 342 (25) :1887-1892
[6]   Clinical end points in coronary stent trials - A case for standardized definitions [J].
Cutlip, Donald E. ;
Windecker, Stephan ;
Mehran, Roxana ;
Boam, Ashley ;
Cohen, David J. ;
van Es, Gerrit-Anne ;
Steg, P. Gabriel ;
Morel, Marie-angele ;
Mauri, Laura ;
Vranckx, Pascal ;
McFadden, Eugene ;
Lansky, Alexandra ;
Hamon, Martial ;
Krucoff, Mitchell W. ;
Serruys, Patrick W. .
CIRCULATION, 2007, 115 (17) :2344-2351
[7]   Impact of design of coronary stents and length of dual antiplatelet therapies on ischaemic and bleeding events: a network meta-analysis of 64 randomized controlled trials and 102 735 patients [J].
D'Ascenzo, Fabrizio ;
Iannaccone, Mario ;
Saint-Hilary, Gaelle ;
Bertaina, Maurizio ;
Pke, Stefanie Schulz-Schu ;
Lee, Cheol Wahn ;
Chieffo, Alaide ;
Helft, Gerard ;
Gili, Sebastiano ;
Barbero, Umberto ;
Zoccai, Giuseppe Biondi ;
Moretti, Claudio ;
Ugo, Fabrizio ;
D'Amico, Maurizio ;
Garbo, Roberto ;
Stone, Gregg ;
Rettegno, Sara ;
Omede, Pierluigi ;
Conrotto, Federico ;
Templin, Christian ;
Colombo, Antonio ;
Park, Seung-Jung ;
Kastrati, Adnan ;
Hildick-Smith, David ;
Gasparini, Mauro ;
Gaita, Fiorenzo .
EUROPEAN HEART JOURNAL, 2017, 38 (42) :3160-3172
[8]   Long-term outcomes of biodegradable versus durable polymer drug-eluting stents in patients with acute ST-segment elevation myocardial infarction: a pooled analysis of individual patient data from three randomised trials [J].
de Waha, Antoinette ;
King, Lamin A. ;
Stefanini, Giulio G. ;
Byrne, Robert A. ;
Serruys, Patrick W. ;
Meier, Bernhard ;
Jueni, Peter ;
Kastrati, Adnan ;
Windecker, Stephan .
EUROINTERVENTION, 2015, 10 (12) :1425-1431
[9]  
Dores H, 2013, J INVASIVE CARDIOL, V25, P330
[10]   Duration of Dual Antiplatelet Therapy After Drug-Eluting Stent Implantation A Systematic Review and Meta-Analysis of Randomized Controlled Trials [J].
Giustino, Gennaro ;
Baber, Usman ;
Sartori, Samantha ;
Mehran, Roxana ;
Mastoris, Ioannis ;
Kini, Annapoorna S. ;
Sharma, Samin K. ;
Pocock, Stuart J. ;
Dangas, George D. .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2015, 65 (13) :1298-1310