Impact of morphological parameters on urban ventilation in compact cities: The case of the Tuscolano-Don Bosco district in Rome

被引:75
作者
Palusci, Olga [1 ,2 ]
Monti, Paolo [1 ]
Cecere, Carlo [1 ]
Montazeri, Hamid [2 ]
Blocken, Bert [2 ,3 ]
机构
[1] Sapienza Univ Rome, Fac Civil & Ind Engn, Dept Civil Bldg & Environm Engn, Rome, Italy
[2] Eindhoven Univ Technol, Dept Built Environm, Bldg Phys & Serv, Eindhoven, Netherlands
[3] Leuven Univ, Dept Civil Engn, Bldg Phys & Sustainable Design, Kasteelpk Arenberg 40,Bus 2447, B-3001 Leuven, Belgium
基金
英国科研创新办公室;
关键词
Urban ventilation; Urban morphology; Compact city; CFD; Mean velocity ratio; Urban renovation plan; PEDESTRIAN WIND COMFORT; PARTICULATE MATTER CONCENTRATIONS; LAGRANGIAN TIME SCALES; POLLUTANT DISPERSION; CITY BREATHABILITY; CFD SIMULATION; AIR-QUALITY; OUTDOOR VENTILATION; NATURAL VENTILATION; BUILDING ARRAYS;
D O I
10.1016/j.scitotenv.2021.150490
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
Air pollution and heat stress are major concerns associated with the liveability, resilience and sustainability of cities. They directly affect health and comfort and are associated with augmented morbidity and mortality and an increase in the energy demand for building ventilation, air cleaning and cooling. Nevertheless, the detrimental effects of poor air quality may partly be mitigated by increased urban ventilation. This strategy is closely related to the level of urbanization and the urban morphology. Therefore, detailed investigations on the impact of different morphologies on urban ventilation are of paramount importance. Computational Fluid Dynamics simulations have been widely used during the last decades to investigate the effects of the urban morphology on the urban ventilation. However, most of these studies focused on idealized building arrangements, while detailed investigations about the role of real urban morphologies are scarce. This study investigates the ventilation in a compact area in the city of Rome, Italy. 3D steady-state Reynolds-averaged Navier-Stokes simulations are performed to analyze the impact of Morphological Parameters (MP) on the urban ventilation. The results show a considerable worsening of urban ventilation with increasing building density with a reduction in the mean wind velocity up to 62% experienced at the pedestrian level (z(p)). Correlations between five MPs, e.g., plan area density, area-weighted mean building height, volume density, facade area density, and non-dimensional mean velocity at pedestrian level and at 10 m height are evaluated, and simple models are obtained using linear regression analysis. Among the selected MPs, the building facade area density shows a remarkable correlation with the non-dimensional mean velocity at z(p) (R-2 = 0.82). Such correlations can be valuable tools for practitioners and urban designers, particularly during the first stage of planning, for highlighting areas potentially vulnerable to poor air conditions without running computationally expensive simulations. (C) 2021 The Authors. Published by Elsevier B.V.
引用
收藏
页数:25
相关论文
共 155 条
  • [81] On the use of non-conformal grids for economic LES of wind flow and convective heat transfer for a wall-mounted cube
    Iousef, S.
    Montazeri, H.
    Blocken, B.
    van Wesemael, P. J. V.
    [J]. BUILDING AND ENVIRONMENT, 2017, 119 : 44 - 61
  • [82] Pedestrian wind comfort around buildings: Comparison of wind comfort criteria based on whole-flow field data for a complex case study
    Janssen, W. D.
    Blocken, B.
    van Hooff, T.
    [J]. BUILDING AND ENVIRONMENT, 2013, 59 : 547 - 562
  • [83] Air quality affected by trees in real street canyons: The case of Marylebone neighbourhood in central London
    Jeanjean, Antoine P. R.
    Buccolieri, Riccardo
    Eddy, James
    Monks, Paul S.
    Leigh, Roland J.
    [J]. URBAN FORESTRY & URBAN GREENING, 2017, 22 : 41 - 53
  • [84] PREDICTION OF LAMINARIZATION WITH A 2-EQUATION MODEL OF TURBULENCE
    JONES, WP
    LAUNDER, BE
    [J]. INTERNATIONAL JOURNAL OF HEAT AND MASS TRANSFER, 1972, 15 (02) : 301 - +
  • [85] Optimization procedures for enhancement of city breathability using arcade design in a realistic high-rise urban area
    Juan, Yu-Hsuan
    Yang, An-Shik
    Wen, Chih-Yung
    Lee, Yee-Ting
    Wang, Po-Chun
    [J]. BUILDING AND ENVIRONMENT, 2017, 121 : 247 - 261
  • [86] Large-eddy simulations on the effects of surface geometry of building arrays on turbulent organized structures
    Kanda, M
    [J]. BOUNDARY-LAYER METEOROLOGY, 2006, 118 (01) : 151 - 168
  • [87] Ventilation efficiency of void space surrounded by buildings with wind blowing over built-up urban area
    Kato, Shinsuke
    Huang, Hong
    [J]. JOURNAL OF WIND ENGINEERING AND INDUSTRIAL AERODYNAMICS, 2009, 97 (7-8) : 358 - 367
  • [88] Wind tunnel tests on the relationship between building density and pedestrian-level wind velocity: Development of guidelines for realizing acceptable wind environment in residential neighborhoods
    Kubota, Tetsu
    Miura, Masao
    Tominaga, Yoshihide
    Mochida, Akashi
    [J]. BUILDING AND ENVIRONMENT, 2008, 43 (10) : 1699 - 1708
  • [89] Launder B. E., 1974, Computer Methods in Applied Mechanics and Engineering, V3, P269, DOI 10.1016/0045-7825(74)90029-2
  • [90] Application of Improved CFD Modeling for Prediction and Mitigation of Traffic-Related Air Pollution Hotspots in a Realistic Urban Street
    Lauriks, Tom
    Longo, Riccardo
    Baetens, Donja
    Derudi, Marco
    Parente, Alessandro
    Bellemans, Aurelie
    Beeck, Jeroen van
    Denys, Siegfried
    [J]. ATMOSPHERIC ENVIRONMENT, 2021, 246