The effect of blood acceleration on the ultrasound power Doppler spectrum

被引:3
作者
Matchenko, O. S. [1 ]
Barannik, E. A. [1 ]
机构
[1] Kharkov Natl Univ, Kharkov, Ukraine
关键词
accelerated blood motion; correlation function; sensitivity function; Doppler power spectrum; spectral width; PULMONARY-ARTERY; FLOW TURBULENCE; ECHOCARDIOGRAPHY; VELOCITY; SIGNALS;
D O I
10.1134/S1063771017050086
中图分类号
O42 [声学];
学科分类号
070206 ; 082403 ;
摘要
The purpose of the present work was to study the influence of blood acceleration and time window length on the power Doppler spectrum for Gaussian ultrasound beams. The work has been carried out on the basis of continuum model of the ultrasound scattering from inhomogeneities in fluid flow. Correlation function of fluctuations has been considered for uniformly accelerated scatterers, and the resulting power Doppler spectra have been calculated. It is shown that within the initial phase of systole uniformly accelerated slow blood flow in pulmonary artery and aorta tends to make the correlation function about 4.89 and 7.83 times wider, respectively, than the sensitivity function of typical probing system. Given peak flow velocities, the sensitivity function becomes, vice versa, about 4.34 and 3.84 times wider, respectively, then the correlation function. In these limiting cases, the resulting spectra can be considered as Gaussian. The optimal time window duration decreases with increasing acceleration of blood flow and equals to 11.62 and 7.54 ms for pulmonary artery and aorta, respectively. The width of the resulting power Doppler spectrum is shown to be defined mostly by the wave vector of the incident field, the duration of signal and the acceleration of scatterers in the case of low flow velocities. In the opposite case geometrical properties of probing field and the average velocity itself are more essential. In the sense of signal-noise ratio, the optimal duration of time window can be found. Abovementioned results may contribute to the improved techniques of Doppler ultrasound diagnostics of cardiovascular system.
引用
收藏
页码:596 / 603
页数:8
相关论文
共 31 条
[21]  
Price DJA, 2000, HEART, V84, P11
[22]   An improved Doppler model for obtaining accurate maximum blood velocities [J].
Ricci, Stefano ;
Matera, Riccardo ;
Tortoli, Piero .
ULTRASONICS, 2014, 54 (07) :2006-2014
[23]  
Scoutt L. M., 2009, ARRS CATEGORICAL COU, V99
[24]   Correlation functions and power spectra of Doppler response signals in ultrasonic medical applications [J].
Skresanova, Iryna V. ;
Barannik, Evgen A. .
ULTRASONICS, 2012, 52 (05) :676-684
[25]   Doppler ultrasound signal spectral response in the measurement of the blood flow turbulence caused by stenosis [J].
Solano, J. ;
Vazquez, M. ;
Rubio, E. ;
Sanchez, I. ;
Fuentes, M. ;
Garcia, F. .
INTERNATIONAL CONGRESS ON ULTRASONICS, PROCEEDINGS, 2010, 3 (01) :605-613
[26]  
SVESHNIKOV A. G., 1978, THEORY FUNCTIONS COM
[27]   Simulation of a pulsatile non-Newtonian flow past a stenosed 2D artery with atherosclerosis [J].
Tian, Fang-Bao ;
Zhu, Luoding ;
Fok, Pak-Wing ;
Lu, Xi-Yun .
COMPUTERS IN BIOLOGY AND MEDICINE, 2013, 43 (09) :1098-1113
[28]   Finding the Peak Velocity in a Flow From Its Doppler Spectrum [J].
Vilkomerson, David ;
Ricci, Stefano ;
Tortoli, Piero .
IEEE TRANSACTIONS ON ULTRASONICS FERROELECTRICS AND FREQUENCY CONTROL, 2013, 60 (10) :2079-2088
[29]  
Wells P N, 1998, Eur J Ultrasound, V7, P3, DOI 10.1016/S0929-8266(98)00006-8
[30]   Pulmonary Artery Acceleration Time Provides an Accurate Estimate of Systolic Pulmonary Arterial Pressure during Transthoracic Echocardiography [J].
Yared, Kibar ;
Noseworthy, Peter ;
Weyman, Arthur E. ;
McCabe, Elizabeth ;
Picard, Michael H. ;
Baggish, Aaron L. .
JOURNAL OF THE AMERICAN SOCIETY OF ECHOCARDIOGRAPHY, 2011, 24 (06) :687-692