Rapid measurement of renal artery blood flow with ungated spiral phase-contrast MRI

被引:16
作者
Park, JB
Santos, JM
Hargreaves, BA
Nayak, KS
Sommer, G
Hu, BS
Nishimura, DG
机构
[1] Stanford Univ, Dept Elect Engn, Magnet Resonance Syst Res Lab, Stanford, CA 94305 USA
[2] Univ So Calif, Dept Elect Engn, Los Angeles, CA 90089 USA
[3] Stanford Univ, Dept Radiol, Stanford, CA 94305 USA
[4] Palo Alto Med Fdn, Palo Alto, CA USA
关键词
renal; vascular; flow; fast imaging; phase-contrast; spiral;
D O I
10.1002/jmri.20325
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: To verify the potential of ungated spiral phase-contrast (USPC), which has been shown to provide accurate and reproducible time-averaged measurements of pulsatile flow, for rapid measurement of renal artery blood flow (RABF) in vivo. Materials and Methods: The RABF rates of 11 normal human subjects and one patient with renal failure were measured with USPC within six seconds. Results: Rapid USPC scans produced reproducible RABF measurements (SD <= 9%) that agreed with the normal RABF rates known from the literature. The RABF rates of the patient with renal failure were substantially less (< 50-65%) than the normal RABF rates. Conclusion: The results demonstrate that it is now possible to obtain rapid and consistent RABF measurements within six seconds with USPC.
引用
收藏
页码:590 / 595
页数:6
相关论文
共 21 条
  • [11] 2-#
  • [12] Multishot rosette trajectories for spectrally selective MR imaging
    Noll, DC
    [J]. IEEE TRANSACTIONS ON MEDICAL IMAGING, 1997, 16 (04) : 372 - 377
  • [13] Rapid measurement of time-averaged blood flow using ungated spiral phase-contrast
    Park, JB
    Olcott, EW
    Nishimura, DG
    [J]. MAGNETIC RESONANCE IN MEDICINE, 2003, 49 (02) : 322 - 328
  • [14] PARK JH, 2003, P 11 ANN M ISMRM TOR
  • [15] PELC NJ, 1994, MAGN RESON QUART, V10, P125
  • [16] SANTOS JM, 2002, P 10 ANN M ISMRM HON
  • [17] Smith HW, 1951, KIDNEY STRUCTURE FUN
  • [18] Renal blood flow: Measurement in vivo with rapid spiral MR imaging
    Sommer, G
    Corrigan, G
    Fredrickson, J
    Sawyer-Glover, A
    Liao, JR
    Myers, B
    Pelc, N
    [J]. RADIOLOGY, 1998, 208 (03) : 729 - 734
  • [19] MAGNETIC-RESONANCE FLUOROSCOPY USING SPIRALS WITH VARIABLE SAMPLING DENSITIES
    SPIELMAN, DM
    PAULY, JM
    MEYER, CH
    [J]. MAGNETIC RESONANCE IN MEDICINE, 1995, 34 (03) : 388 - 394
  • [20] ACCURACY OF PHASE-CONTRAST FLOW MEASUREMENTS IN THE PRESENCE OF PARTIAL-VOLUME EFFECTS
    TANG, C
    BLATTER, DD
    PARKER, DL
    [J]. JMRI-JOURNAL OF MAGNETIC RESONANCE IMAGING, 1993, 3 (02): : 377 - 385