Disposable and portable electrochemical aptasensor for label free detection of aflatoxin B1 in alcoholic beverages

被引:115
作者
Goud, K. Yugender [1 ,2 ]
Catanante, Gaelle [1 ]
Hayat, Akhtar [1 ,3 ]
Satyanarayana, M. [2 ]
Gobi, K. Vengatajalabathy [2 ]
Marty, Jean Louis [1 ]
机构
[1] Univ Perpignan, BAE Lab, 52 Ave Paul Alduy, F-66860 Perpignan, France
[2] Natl Inst Technol, Dept Chem, Warangal 506004, Telangana, India
[3] COMSATS Inst Informat Technol CIIT, Interdisciplinary Res Ctr Biomed Mat, Lahore 54000, Pakistan
关键词
Aflatoxin B1; Disposable and portable aptasensor; Label free detection; Alcoholic beverages; Screen printed carbon electrodes; FREE IMPEDIMETRIC APTASENSOR; MONOCLONAL-ANTIBODY; B-1; CONTAMINATION; OCHRATOXIN;
D O I
10.1016/j.snb.2016.05.112
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Aflotoxin B1 (AFB1) is the most prevalent and toxic contaminant for human beings and animals among all the aflatoxins (AFs). Additionally, AFB1 is documented as a highly carcinogenic and mutagenic contaminant in the literature. Therefore, it is of vital importance to monitor AFB1 contamination to reduce its health associated risks. In the present work, we have designed a label-free electrochemical impedimetric aptasensor for aflatoxin B1 detection. Herein, we compared the analytical performances of two aptamer sequences (seqA and seqB). The detection is based on specific recognition by the aptamer covalently-bound as compact monolayer on screen printed carbon electrodes (SPCEs) via diazonium coupling reaction. The quantification of AFB1 was achieved by using electrochemical impedance spectroscopy. A dynamic quantification range from 0.125 ng mL(-1) to 16 ng mL(-1) was obtained with both types of aptamer sequences while the detection limits were 0.12 ng mL(-1) and 0.25 ng mL(-1) for seqA and seqB respectively. For real sample applications, the developed aptasensors were demonstrated in beer and wine samples, and good recovery levels in the range of 92-102% were recorded for AFB1 detection. (C) 2016 Elsevier B.V. All rights reserved.
引用
收藏
页码:466 / 473
页数:8
相关论文
共 22 条
[1]   A novel electrochemical piezoelectric label free immunosensor for aflatoxin B1 detection in groundnut [J].
Chauhan, Ruchika ;
Solanki, Pratima R. ;
Singh, Jay ;
Mukherjee, Irani ;
Basu, T. ;
Malhotra, B. D. .
FOOD CONTROL, 2015, 52 :60-70
[2]   Reduction of aflatoxin B1 contamination in wheat by various cooking treatments [J].
Hwang, JH ;
Lee, KG .
FOOD CHEMISTRY, 2006, 98 (01) :71-75
[3]   Detection of aflatoxin B1 with immunochromatographic test strips: Enhanced signal sensitivity using gold nanoflowers [J].
Ji, Yanwei ;
Ren, Meiling ;
Li, Yanping ;
Huang, Zhibing ;
Shu, Mei ;
Yang, Hongwei ;
Xiong, Yonghua ;
Xu, Yang .
TALANTA, 2015, 142 :206-212
[4]   Highly sensitive SERS-based immunoassay of aflatoxin B1 using silica-encapsulated hollow gold nanoparticles [J].
Ko, Juhui ;
Lee, Chankil ;
Choo, Jaebum .
JOURNAL OF HAZARDOUS MATERIALS, 2015, 285 :11-17
[5]   Direct competitive ELISA based on a monoclonal antibody for detection of aflatoxin B1.: Stabilization of ELISA kit components and application to grain samples [J].
Kolosova, AY ;
Shim, WB ;
Yang, ZY ;
Eremin, SA ;
Chung, DH .
ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2006, 384 (01) :286-294
[6]  
Lee S. H., 2015, Biosens. Bioelectron
[7]   Aflatoxin contamination of commercial maize products during an outbreak of acute aflatoxicosis in eastern and central Kenya [J].
Lewis, L ;
Onsongo, M ;
Njapau, H ;
Schurz-Rogers, H ;
Luber, G ;
Kieszak, S ;
Nyamongo, J ;
Backer, L ;
Dahiye, AM ;
Misore, A ;
DeCock, K ;
Rubin, C .
ENVIRONMENTAL HEALTH PERSPECTIVES, 2005, 113 (12) :1763-1767
[8]   An iridium oxide nanoparticle and polythionine thin film based platform for sensitive Leishmania DNA detection [J].
Mayorga-Martinez, Carmen C. ;
Chamorro-Garcia, Alejandro ;
Serrano, Lorena ;
Rivas, Lourdes ;
Quesada-Gonzalez, Daniel ;
Altet, Laura ;
Francino, Olga ;
Sanchez, Armand ;
Merkoci, Arben .
JOURNAL OF MATERIALS CHEMISTRY B, 2015, 3 (26) :5166-5171
[9]   A label free aptasensor for Ochratoxin A detection in cocoa beans: An application to chocolate industries [J].
Mishra, Rupesh K. ;
Hayat, Akhtar ;
Catanante, Gaelle ;
Ocana, Cristina ;
Marty, Jean-Louis .
ANALYTICA CHIMICA ACTA, 2015, 889 :106-112
[10]   A comparison of four protocols for the immobilization of an aptamer on graphite composite electrodes [J].
Ocana, Cristina ;
del Valle, Manel .
MICROCHIMICA ACTA, 2014, 181 (3-4) :355-363