Cervical spine movement during laryngoscopy using the Airway Scope compared with the Macintosh laryngoscope

被引:49
作者
Hirabayashi, Y.
Fujita, A.
Seo, N.
Sugimoto, H.
机构
[1] Jichi Med Univ, Dept Anaesthesiol & Crit Care Med, Shimotsuke, Tochigi 3290498, Japan
[2] Jichi Med Univ, Dept Radiol, Shimotsuke, Tochigi 3290498, Japan
关键词
D O I
10.1111/j.1365-2044.2007.05188.x
中图分类号
R614 [麻醉学];
学科分类号
100217 ;
摘要
The Airway Scope is a new rigid laryngoscope. This intubation device provides a non-line-of sight view of the glottis. A non-line-of sight view is expected to cause less movement of the cervical spine during laryngeal visualisation. We compared the degree of cervical spine movement during laryngoscopy with the Airway Scope and conventional direct laryngoscope. Twenty patients requiring general anaesthesia and tracheal intubation were studied. Movements of the cervical spine were measured using radiography in the same patient during laryngoscopy with the Airway Scope and a Macintosh laryngoscope. Cervical spine movement during laryngoscopy with the Airway Scope was 37%, 37% and 68% less than that with the Macintosh laryngoscope at the C0/C1, C1/C2 and C3/C4 motion segments, respectively (p < 0.05). The movement of the atlanto-occipital distance using the Airway Scope was 42% less than that during laryngoscopy using the Macintosh laryngoscope (p < 0.05). Laryngoscopy using the Airway Scope involves less movement of the cervical spine compared to conventional laryngoscopy using the Macintosh laryngoscope.
引用
收藏
页码:1050 / 1055
页数:6
相关论文
共 11 条
[1]   Airway Scope for difficult intubation [J].
Asai, T. ;
Enomoto, Y. ;
Okuda, Y. .
ANAESTHESIA, 2007, 62 (02) :199-199
[2]   Airway management in adults after cervical spine trauma [J].
Crosby, Edward T. .
ANESTHESIOLOGY, 2006, 104 (06) :1293-1318
[3]   CERVICAL-SPINE MOVEMENT DURING LARYNGOSCOPY WITH THE BULLARD, MACINTOSH, AND MILLER LARYNGOSCOPES [J].
HASTINGS, RH ;
VIGIL, AC ;
HANNA, R ;
YANG, BY ;
SARTORIS, DJ .
ANESTHESIOLOGY, 1995, 82 (04) :859-869
[4]   DISPOSITION OF CERVICAL-VERTEBRAE, ATLANTO-AXIAL JOINT, HYOID AND MANDIBLE DURING X-RAY LARYNGOSCOPY [J].
HORTON, WA ;
FAHY, L ;
CHARTERS, P .
BRITISH JOURNAL OF ANAESTHESIA, 1989, 63 (04) :435-438
[5]   Description and first clinical application of AirWay Scope for tracheal intubation [J].
Koyama, Jun-ichi ;
Aoyama, Tatsuro ;
Kusano, Yoshikazu ;
Seguchi, Tatsuya ;
Kawagishi, Kyutaro ;
Iwashita, Tomomi ;
Okamoto, Kazufumi ;
Okudera, Hiroshi ;
Takasuna, Hiroshi ;
Hongo, Kazuhiro .
JOURNAL OF NEUROSURGICAL ANESTHESIOLOGY, 2006, 18 (04) :247-250
[6]   CERVICAL-SPINE MOVEMENT DURING OROTRACHEAL INTUBATION [J].
MAJERNICK, TG ;
BIENIEK, R ;
HOUSTON, JB ;
HUGHES, HG .
ANNALS OF EMERGENCY MEDICINE, 1986, 15 (04) :417-420
[7]   OROTRACHEAL INTUBATION IN PATIENTS WITH POTENTIAL CERVICAL-SPINE INJURIES - AN INDICATION FOR THE GUM ELASTIC BOUGIE [J].
NOLAN, JP ;
WILSON, ME .
ANAESTHESIA, 1993, 48 (07) :630-633
[8]   Movement of the upper cervical spine during laryngoscopy: a comparison of the Bonfils intubation fibrescope and the Macintosh laryngoscope [J].
Rudolph, C ;
Schneider, JP ;
Wallenborn, J ;
Schaffranietz, L .
ANAESTHESIA, 2005, 60 (07) :668-672
[9]   Cervical spine motion with direct laryngoscopy and orotracheal intubation: An in vivo cinefluoroscopic study of subjects without cervical abnormality [J].
Sawin, PD ;
Todd, MM ;
Traynelis, VC ;
Farrell, SB ;
Nader, A ;
Sato, Y ;
Clausen, JD ;
Goel, VK .
ANESTHESIOLOGY, 1996, 85 (01) :26-36
[10]  
Takenaka I, 2007, CAN J ANAESTH, V54, P129, DOI 10.1007/BF03022009