Dialysate and Blood Temperature During Hemodialysis: Comparing Isothermic Dialysis With a Single-Pass Batch System

被引:6
作者
Dhondt, Annemieke [1 ]
Eloot, Sunny [1 ]
Verbeke, Francis [1 ]
Vanholder, Raymond [1 ]
机构
[1] Ghent Univ Hosp, Nephrol Sect, B-9000 Ghent, Belgium
关键词
Dialysate; Dialysis; Hemodialysis; Hemodynamic; Temperature; RENAL-FAILURE; STABILITY; HYPOTENSION; DYSFUNCTION; PRESSURE;
D O I
10.1111/j.1525-1594.2009.00981.x
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
The Genius is a convenient single-pass batch hemodialysis system. Dialysate is heated during the preparation phase. Once the container is filled at one of the three available starting temperatures, dialysate cools spontaneously. As dialysate temperature plays an important role in hemodynamic stability, knowledge of the instantaneous dialysate temperature is important. We documented the evolution of dialysate temperature during Genius dialysis with dialysate prepared at two different temperatures (low and medium) as well as its effect on blood temperature and hemodynamic stability. Genius dialysis was compared to isothermic dialysis obtained by a module programmed to obtain a constant blood temperature. With Genius, dialysate temperature progressively decreased from 36.3 (low) and 37.6 degrees C (medium) in the beginning to 34.4 and 35.3 degrees C at the end of the session, both following first-order kinetics. During isothermic dialysis, dialysate cooled from 37.3 to 35.4 degrees C, being warmer than with Genius low. Blood temperature decreased during dialysis with Genius low, from 36.4 to 36.2 degrees C, whereas with medium temperature, blood temperature initially rose from 36.4 degrees C at 15 min to 36.5 and 36.6 degrees C at 30 and 60 min, respectively, followed by a decrease from 180 min onward, to 36.4 degrees C at the end. During isothermic dialysis, blood temperature remained stable, as expected. Blood pressure decreased during all three schedules, with the highest value at 15 min during isothermic dialysis, and at the end of the session, the lowest value with isothermic dialysis.
引用
收藏
页码:1132 / 1137
页数:6
相关论文
共 26 条
[1]   Effect of cool temperature dialysate on the quality and patients' perception of haemodialysis [J].
Ayoub, A ;
Finlayson, M .
NEPHROLOGY DIALYSIS TRANSPLANTATION, 2004, 19 (01) :190-194
[2]  
Dheenan S, 2001, KIDNEY INT, V59, P1175, DOI 10.1046/j.1523-1755.2001.00604.x
[3]   Dialysate partitioning in the Genius® batch hemodialysis system:: Effect of temperature and solute concentration [J].
Dhondt, A ;
Eloot, S ;
De Wachter, D ;
De Smet, R ;
Waterloos, MA ;
Glorieux, G ;
Lameire, N ;
Verdonck, P ;
Vanholder, R .
KIDNEY INTERNATIONAL, 2005, 67 (06) :2470-2476
[4]   Studies on dialysate mixing in the Genius® single-pass batch system for hemodialysis therapy [J].
Dhondt, AW ;
Vanholder, RC ;
De Smet, RV ;
Claus, SA ;
Waterloos, MA ;
Glorieux, GL ;
Delanghe, JR ;
Lameire, NH .
KIDNEY INTERNATIONAL, 2003, 63 (04) :1540-1547
[5]   Temperature and concentration distribution within the Genius® dialysate container [J].
Eloot, Sunny ;
Dhondt, Annemieke ;
Vierendeels, Jan ;
De Wachter, Dirk ;
Verdonck, Pascal ;
Vanholder, Raymond .
NEPHROLOGY DIALYSIS TRANSPLANTATION, 2007, 22 (10) :2962-2969
[6]   Experience with the GENIUS® hemodialysis system [J].
Fassbinder, W .
KIDNEY & BLOOD PRESSURE RESEARCH, 2003, 26 (02) :96-99
[7]   The protective effect of cool dialysate is dependent on patients' predialysis temperature [J].
Fine, A ;
Penner, B .
AMERICAN JOURNAL OF KIDNEY DISEASES, 1996, 28 (02) :262-265
[8]   Technology Insight: treatment of renal failure in the intensive care unit with extended dialysis [J].
Fliser, D ;
Kielstein, JT .
NATURE CLINICAL PRACTICE NEPHROLOGY, 2006, 2 (01) :32-39
[9]   INTERACTION OF THERMAL AND BARORECEPTOR REFLEXES IN MAN [J].
HEISTAD, DD ;
ABBOUD, FM ;
MARK, AL ;
SCHMID, PG .
JOURNAL OF APPLIED PHYSIOLOGY, 1973, 35 (05) :581-586
[10]   EFFECTS OF COOLER TEMPERATURE DIALYSATE ON HEMODYNAMIC STABILITY IN PROBLEM DIALYSIS PATIENTS [J].
JOST, CMT ;
AGARWAL, R ;
KHAIRELDIN, T ;
GRAYBURN, PA ;
VICTOR, RG ;
HENRICH, WL .
KIDNEY INTERNATIONAL, 1993, 44 (03) :606-612