Retrieval of Displaced Woven EndoBridge Intrasaccular Flow Disruptor Using Solitaire Platinum Revascularization Device

被引:5
作者
Banez, Ramon Martin Francisco [1 ]
Chong, Winston [2 ]
机构
[1] Royal Hobart Hosp, Dept Med Imaging, Intervent Neuroradiol Serv, Hobart, Tas, Australia
[2] Monash Hlth, Intervent Neuroradiol Unit, Monash Imaging, Melbourne, Vic, Australia
关键词
Aneurysm; Endovascular procedures; Blood vessel prosthesis;
D O I
10.5469/neuroint.2022.00059
中图分类号
R74 [神经病学与精神病学];
学科分类号
摘要
The Woven EndoBridge (WEB; MicroVention, Aliso Viejo, CA, USA) intrasaccular flow disruptor is a therapeutic option for wide neck bifurcation intracranial aneurysms that does not require the use of adjunctive techniques such as stents or balloon remodeling. As with other endovascular devices, displacement of the WEB is a recognized complication. Few reports have been published regarding the management of this type of complication. We describe a case of retrieval of a displaced WEB using a Solitaire Platinum revascularization device (Medtronic, Minneapolis, MN, USA). Interventionists should be aware of this option in the management of such a complication.
引用
收藏
页码:106 / 109
页数:4
相关论文
共 7 条
[1]   Efficacy and Safety of the Woven EndoBridge (WEB) Device for the Treatment of Intracranial Aneurysms: A Systematic Review and Meta-Analysis [J].
Asnafi, S. ;
Rouchaud, A. ;
Pierot, L. ;
Brinjikji, W. ;
Murad, M. H. ;
Kallmes, D. F. .
AMERICAN JOURNAL OF NEURORADIOLOGY, 2016, 37 (12) :2287-2292
[2]   Dislocation of aWEB Device into the Middle Cerebral Artery: Removal with the Alligator Retrieval Device [J].
Koenig, I. ;
Weber, A. ;
Weber, W. ;
Fischer, S. .
CLINICAL NEURORADIOLOGY, 2019, 29 (02) :361-364
[3]   Stent Retriever Use for Retrieval of Displaced Microcoils: A Consecutive Case Series [J].
Leslie-Mazwi, T. M. ;
Heddier, M. ;
Nordmeyer, H. ;
Stauder, M. ;
Velasco, A. ;
Mosimann, P. J. ;
Chapot, R. .
AMERICAN JOURNAL OF NEURORADIOLOGY, 2013, 34 (10) :1996-1999
[4]   Endovascular retrieval of a dislocated coil in the peroneal artery with a stent retriever [J].
Nikoubashman, Omid ;
Badenschier, Rico ;
Mueller, Marguerite ;
Brockmann, Carolin ;
Schubert, Gerrit ;
Brockmann, Marc-Alexander ;
Muehlenbruch, Georg ;
Clusmann, Hans Rainer ;
Wiesmann, Martin .
BJR CASE REPORTS, 2016, 2 (01)
[5]   WEB Intrasaccular Flow Disruptor-Prospective, Multicenter Experience in 83 Patients with 85 Aneurysms [J].
Papagiannaki, C. ;
Spelle, L. ;
Januel, A. -C. ;
Benaissa, A. ;
Gauvrit, J. -Y. ;
Costalat, V. ;
Desal, H. ;
Turjman, F. ;
Velasco, S. ;
Barreau, X. ;
Courtheoux, P. ;
Cognard, C. ;
Herbreteau, D. ;
Moret, J. ;
Pierot, L. .
AMERICAN JOURNAL OF NEURORADIOLOGY, 2014, 35 (11) :2106-2111
[6]   Safety and efficacy of aneurysm treatment with WEB in the cumulative population of three prospective, multicenter series [J].
Pierot, Laurent ;
Moret, Jacques ;
Barreau, Xavier ;
Szikora, Istvan ;
Herbreteau, Denis ;
Turjman, Francis ;
Holtmannspotter, Markus ;
Januel, Anne-Christine ;
Costalat, Vincent ;
Fiehler, Jens ;
Klisch, Joachim ;
Gauvrit, Jean-Yves ;
Weber, Werner ;
Desal, Hubert ;
Velasco, Stephane ;
Liebig, Thomas ;
Stockx, Luc ;
Berkefeld, Joachim ;
Molyneux, Andrew ;
Byrne, James ;
Spelle, Laurent .
JOURNAL OF NEUROINTERVENTIONAL SURGERY, 2018, 10 (06) :553-559
[7]   WEB Treatment of Ruptured Intracranial Aneurysms [J].
van Rooij, W. J. ;
Peluso, J. P. ;
Bechan, R. S. ;
Sluzewski, M. .
AMERICAN JOURNAL OF NEURORADIOLOGY, 2016, 37 (09) :1679-1683