Multi-beam X-ray source breast tomosynthesis reconstruction with different algorithms

被引:5
|
作者
Zhou, Weihua [1 ]
Qian, Xin [3 ,4 ]
Lu, Jianping [3 ,4 ,5 ]
Zhou, Otto [3 ,4 ,5 ]
Chen, Ying [1 ,2 ]
机构
[1] So Illinois Univ, Dept Elect & Comp Engn, Carbondale, IL 62901 USA
[2] So Illinois Univ, Biomed Engn Grad Program, Carbondale, IL 62901 USA
[3] Univ N Carolina, Dept Phys & Astron, Chapel Hill, NC 27599 USA
[4] Univ N Carolina, Dept Curriculum Appl Sci & Engn, Chapel Hill, NC 27599 USA
[5] Univ N Carolina, Lineberger Comprehen Cancer Ctr, Chapel Hill, NC 27599 USA
关键词
mammography; tomosynthesis; carbon-nanotube; back projection (BP); filtered back projection (FBP); matrix inversion tomosynthesis (MITS); maximum likelihood expectation maximization (MLEM); simultaneous algebraic reconstruction technique (SART); ART;
D O I
10.1117/12.844295
中图分类号
O43 [光学];
学科分类号
070207 ; 0803 ;
摘要
Digital breast tomosynthesis is a new technique to improve the early detection of breast cancer by providing three-dimensional reconstruction volume of the object with limited-angle projection images. This paper investigated the image reconstruction with a standard biopsy training breast phantom using a novel multi-beam X-ray sources breast tomosynthesis system. Carbon nanotube technology based X-ray tubes were lined up along a parallel-imaging geometry to decrease the motion blur. Five representative reconstruction algorithms, including back projection (BP), filtered back projection (FBP), matrix inversion tomosynthesis (MITS), maximum likelihood expectation maximization (MLEM) and simultaneous algebraic reconstruction technique (SART), were investigated to evaluate the image reconstruction of the tomosynthesis system. Reconstructed images of the masses and micro-calcification clusters embedded in the phantom were studied. The evaluated multi-beam X-ray breast tomosynthesis system is able to generate three-dimensional information of the breast phantom with clearly-identified regions of the masses and calcifications. Future study will be done soon to further improve the imaging parameters' measurement and reconstruction.
引用
收藏
页数:8
相关论文
共 50 条
  • [21] Image formation by continuous writing with multi-beam in x-ray nanolithography
    Toyota, E
    Washio, M
    MICROPROCESSES AND NANOTECHNOLOGY 2001, DIGEST OF PAPERS, 2001, : 140 - 141
  • [22] Scanner for Integrated X-Ray Breast Tomosynthesis and Molecular Breast Imaging Tomosynthesis
    Williams, Mark B.
    Judy, Patricia G.
    Gong, Zongyi
    Graham, Audrey E.
    Majewski, Stan
    Gunn, Spencer
    DIGITAL MAMMOGRAPHY, 2010, 6136 : 444 - +
  • [23] On a new multi-source X-ray tube concept for minimizing imaging time in digital breast tomosynthesis
    Behling, Rolf
    PHYSICA MEDICA-EUROPEAN JOURNAL OF MEDICAL PHYSICS, 2021, 88 : 20 - 22
  • [24] A prototype Multi-X-ray-source array (MXA) for digital breast tomosynthesis
    Becker, Amy E.
    Hernandez, Andrew M.
    Boone, John M.
    Schwoebel, Paul R.
    PHYSICS IN MEDICINE AND BIOLOGY, 2020, 65 (23):
  • [25] Use of multi-beam scattering radiation for the absolute X-ray energy calibration
    Aghasyan, M. M.
    Grigoryan, A. H.
    Toneyan, A. H.
    Tsakanov, V. M.
    BRILLIANT LIGHT IN LIFE AND MATERIAL SCIENCES, 2007, : 479 - +
  • [26] A PROPOSED MULTI-BEAM X-RAY MONOCHROMATOR FOR SYNCHROTRON RADIATION - THEORETICAL CONSIDERATIONS
    LO, CM
    CHANG, SL
    JOURNAL DE PHYSIQUE, 1987, 48 (C-9): : 75 - 78
  • [27] X-RAY RESONANCE MULTI-BEAM DIFFRACTION: EXPERIMENTS AND THE PERTURBATIVE BETHE APPROXIMATION
    Stetsko, Y. P.
    Lin, G. Y.
    Huang, Y. S.
    Chao, C. H.
    Lee, Y. R.
    Chang, S. -L.
    ACTA CRYSTALLOGRAPHICA A-FOUNDATION AND ADVANCES, 2002, 58 : C370 - C370
  • [28] X-ray waveguide arrays: tailored near fields by multi-beam interference
    Zhong, Q.
    Osterhoff, M.
    Wen, M. W.
    Wang, Z. S.
    Salditt, T.
    X-RAY SPECTROMETRY, 2017, 46 (02) : 107 - 115
  • [29] X-band thermionic cathode RF gun and multi-beam Compton scattering monochromatic tunable X-ray source
    Sakamoto, Fumito
    Uesaka, Mitsuru
    Dobashi, Katsuhiro
    Fukasawa, Atsushi
    Yamamoto, Tomohiko
    Urakawa, Junji
    Higo, Toshiyasu
    Akemoto, Mitsuo
    Matsuo, Kenichi
    Sakae, Hisaharu
    Yamamoto, Masashi
    JOURNAL OF THE KOREAN PHYSICAL SOCIETY, 2006, 49 (01) : 286 - 297
  • [30] A Spatially Distributed X-Ray Source Array for High Resolution Digital Breast Tomosynthesis
    Qian, X.
    Yang, G.
    Sultana, S.
    Gidcumb, E.
    Tucker, A.
    Spronk, D.
    Sprenger, F.
    Lu, J.
    Zhou, O.
    MEDICAL PHYSICS, 2011, 38 (06)