Multi-beam X-ray source breast tomosynthesis reconstruction with different algorithms

被引:5
作者
Zhou, Weihua [1 ]
Qian, Xin [3 ,4 ]
Lu, Jianping [3 ,4 ,5 ]
Zhou, Otto [3 ,4 ,5 ]
Chen, Ying [1 ,2 ]
机构
[1] So Illinois Univ, Dept Elect & Comp Engn, Carbondale, IL 62901 USA
[2] So Illinois Univ, Biomed Engn Grad Program, Carbondale, IL 62901 USA
[3] Univ N Carolina, Dept Phys & Astron, Chapel Hill, NC 27599 USA
[4] Univ N Carolina, Dept Curriculum Appl Sci & Engn, Chapel Hill, NC 27599 USA
[5] Univ N Carolina, Lineberger Comprehen Cancer Ctr, Chapel Hill, NC 27599 USA
来源
MEDICAL IMAGING 2010: PHYSICS OF MEDICAL IMAGING | 2010年 / 7622卷
关键词
mammography; tomosynthesis; carbon-nanotube; back projection (BP); filtered back projection (FBP); matrix inversion tomosynthesis (MITS); maximum likelihood expectation maximization (MLEM); simultaneous algebraic reconstruction technique (SART); ART;
D O I
10.1117/12.844295
中图分类号
O43 [光学];
学科分类号
070207 ; 0803 ;
摘要
Digital breast tomosynthesis is a new technique to improve the early detection of breast cancer by providing three-dimensional reconstruction volume of the object with limited-angle projection images. This paper investigated the image reconstruction with a standard biopsy training breast phantom using a novel multi-beam X-ray sources breast tomosynthesis system. Carbon nanotube technology based X-ray tubes were lined up along a parallel-imaging geometry to decrease the motion blur. Five representative reconstruction algorithms, including back projection (BP), filtered back projection (FBP), matrix inversion tomosynthesis (MITS), maximum likelihood expectation maximization (MLEM) and simultaneous algebraic reconstruction technique (SART), were investigated to evaluate the image reconstruction of the tomosynthesis system. Reconstructed images of the masses and micro-calcification clusters embedded in the phantom were studied. The evaluated multi-beam X-ray breast tomosynthesis system is able to generate three-dimensional information of the breast phantom with clearly-identified regions of the masses and calcifications. Future study will be done soon to further improve the imaging parameters' measurement and reconstruction.
引用
收藏
页数:8
相关论文
共 25 条
[1]   SIMULTANEOUS ALGEBRAIC RECONSTRUCTION TECHNIQUE (SART) - A SUPERIOR IMPLEMENTATION OF THE ART ALGORITHM [J].
ANDERSEN, AH ;
KAK, AC .
ULTRASONIC IMAGING, 1984, 6 (01) :81-94
[2]  
Chen Y, 2009, P SPIE, V7258
[3]  
Chen Y., 2007, THESIS DUKE U
[4]  
CHEN Y, 2004, RAD SOC N AM RSNA 90
[5]   Importance of point-by-point back projection correction for isocentric motion in digital breast tomosynthesis: Relevance to morphology of structures such as microcalcifications [J].
Chen, Ying ;
Lo, Joseph Y. ;
Dobbins, James T., III .
MEDICAL PHYSICS, 2007, 34 (10) :3885-3892
[6]   Gaussian frequency blending algorithm with Matrix Inversion Tomosynthesis (MITS) and Filtered Back Projection (FBP) for better digital breast tomosynthesis reconstruction [J].
Chen, Ying ;
Lo, Joseph Y. ;
Baker, Jay A. ;
Dobbins, James T., III .
MEDICAL IMAGING 2006: PHYSICS OF MEDICAL IMAGING, PTS 1-3, 2006, 6142
[7]  
Dobbins III James T., 1990, US Patent, Patent No. [US4903204 A, 4903204]
[8]   Digital x-ray tomosynthesis: current state of the art and clinical potential [J].
Dobbins, JT ;
Godfrey, DJ .
PHYSICS IN MEDICINE AND BIOLOGY, 2003, 48 (19) :R65-R106
[9]  
Lalush DS, 2006, I S BIOMED IMAGING, P1180
[10]  
LANGE K, 1984, J COMPUT ASSIST TOMO, V8, P306