Phantom gastric mucosa for evaluating computed radiography in double-contrast upper gastrointestinal examinations

被引:0
作者
Murakami, M [1 ]
Watanabe, H [1 ]
Nakata, H [1 ]
机构
[1] UNIV OCCUPAT & ENVIRONM HLTH,SCH MED,DEPT RADIOL,YAHATANISHI KU,KITAKYUSHU,FUKUOKA 807,JAPAN
关键词
stomach; phantom; radiography; storage phosphor; ROC;
D O I
暂无
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: To rest the clinical usefulness of computed radiography (CR) with a storage phosphor plate in upper gastrointestinal radiographic examinations, a newly devised phantom gastric mucosa was used. Material and Methods. Simulated small elevated and depressed lesions were created on a phantom gastric mucosa made from a styrofoam ''plate''. Twenty-four sets of each CR and screen-film radiographs (SR) were obtained using phototimed exposures. Receiver operating characteristic (ROC) study and visual ranking using these images were performed. Results. There was no significant difference between the ROC curves of CR and SR. By visual ranking, CR was equal to or better than SR in most cases. In no case was SR definitely superior to CR. Conclusion: CR can be safely applied in upper gastrointestinal roentgenologic examinations.
引用
收藏
页码:204 / 207
页数:4
相关论文
共 12 条
  • [2] A METHOD OF COMPARING THE AREAS UNDER RECEIVER OPERATING CHARACTERISTIC CURVES DERIVED FROM THE SAME CASES
    HANLEY, JA
    MCNEIL, BJ
    [J]. RADIOLOGY, 1983, 148 (03) : 839 - 843
  • [3] DIGITAL GASTROINTESTINAL IMAGING - THE EFFECT OF PIXEL SIZE ON DETECTION OF SUBTLE MUCOSAL ABNORMALITIES
    KASTAN, DJ
    ACKERMAN, LV
    FECZKO, PJ
    [J]. RADIOLOGY, 1987, 162 (03) : 853 - 856
  • [4] KEHLER M, 1989, ACTA RADIOL, V30, P581
  • [5] INTERPRETATION OF SUBTLE INTERSTITIAL LUNG ABNORMALITIES - CONVENTIONAL VERSUS STORAGE PHOSPHOR RADIOGRAPHY
    KIDO, S
    IKEZOE, J
    TAKEUCHI, N
    KONDOH, H
    TOMIYAMA, N
    JOKOH, T
    KOHNO, N
    TAKASHIMA, S
    YAMAGAMI, H
    NAITO, H
    ARISAWA, J
    MORIMOTO, S
    KOZUKA, T
    [J]. RADIOLOGY, 1993, 187 (02) : 527 - 533
  • [6] LEE KR, 1991, RADIOGRAPHICS, V11, P1013, DOI 10.1148/radiographics.11.6.1749846
  • [8] MURPHY MD, 1992, AJR, V1589, P19
  • [9] PORTABLE CHEST IMAGING - COMPARISON OF STORAGE PHOSPHOR DIGITAL, ASYMMETRIC SCREEN-FILM, AND CONVENTIONAL SCREEN-FILM SYSTEMS
    NIKLASON, LT
    CHAN, HP
    CASCADE, PN
    CHANG, CL
    CHEE, PW
    MATHEWS, JF
    [J]. RADIOLOGY, 1993, 186 (02) : 387 - 393
  • [10] DIGITAL STORAGE PHOSPHOR IMAGING VERSUS CONVENTIONAL FILM RADIOGRAPHY IN CT-DOCUMENTED CHEST DISEASE
    SCHAEFER, CM
    GREENE, R
    OESTMANN, JW
    HALL, DA
    LLEWELLYN, HJ
    MCCARTHY, KA
    PILESPELLMAN, ER
    RUBENS, JR
    [J]. RADIOLOGY, 1990, 174 (01) : 207 - 210