A Non-Invasive Flexible Glucose Monitoring Sensor Using a Broadband Reject Filter

被引:18
|
作者
Bteich, Moussa [1 ]
Hanna, Jessica [2 ]
Costantine, Joseph [1 ]
Kanj, Rouwaida [1 ]
Tawk, Youssef [1 ]
Ramadan, Ali H. [1 ]
Eid, Assaad A. [3 ]
机构
[1] Amer Univ Beirut, Elect & Comp Engn Dept, Beirut 11072020, Lebanon
[2] Amer Univ Beirut, Biomed Engn Program, Beirut 11072020, Lebanon
[3] Amer Univ Beirut, Dept Anat Cell Biol & Physiol Sci, Beirut 11072020, Lebanon
关键词
Sugar; Broadband communication; Resonator filters; Resonators; Monitoring; Microwave filters; Scattering parameters; Broadband reject filter; Clarke error grid; clinical trials; dielectric characterization; non-invasive glucose monitoring sensor;
D O I
10.1109/JERM.2020.3023053
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
In this paper, a novel, highly accurate, non-invasive glucose-monitoring sensor that is based on a flexible broadband reject filter is presented. The filter topology comprises a tapered feed line at a top layer that excites four open loop resonators on the bottom layer. The broadband reject response is achieved by relying on a modified log-periodic distribution of the open loop resonators. The embedded resonators are reduced in size and are designed to exhibit an enhanced sensitivity to track the variations of the glucose level across the 1.25-2.65 GHz frequency span. The proposed flexible filter is tested within in-vitro, ex-vivo and in-vivo setups. A high correlation between the scattering parameters of the proposed sensor and the variations in glucose levels is attained. Regression models are developed using experimental data obtained from healthy patients that are subjected to glucose tolerance tests. Results demonstrate less than 4% mean absolute relative difference between the reference and estimated glucose levels, and the predicted glucose levels lie 100% within the clinically acceptable zones as shown by the Clarke Error Grid analysis.
引用
收藏
页码:139 / 147
页数:9
相关论文
共 50 条
  • [31] Non-Invasive Blood Glucose Monitoring Using a Curved Goubau Line
    Liu, Louis W. Y.
    Kandwal, Abhishek
    Cheng, Qingsha
    Shi, Hongjian
    Tobore, Igbe
    Nie, Zedong
    ELECTRONICS, 2019, 8 (06):
  • [32] Non-invasive method for blood glucose monitoring using ECG signal
    Arbi, Khadidja Fellah
    Soulimane, Sofiane
    Saffih, Faycal
    POLISH JOURNAL OF MEDICAL PHYSICS AND ENGINEERING, 2023, 29 (01): : 1 - 9
  • [33] Compact Continuous Non-Invasive Blood Glucose Monitoring using Bluetooth
    Sreenivas, Chaithanya
    Laha, Soumyasanta
    2019 IEEE BIOMEDICAL CIRCUITS AND SYSTEMS CONFERENCE (BIOCAS 2019), 2019,
  • [34] A Novel Non-Invasive Blood Glucose Monitoring Approach Using Saliva
    Malik, Sarul
    Gupta, Shalini
    Khadgawat, Rajesh
    Anand, Sneh
    2015 IEEE INTERNATIONAL CONFERENCE ON SIGNAL PROCESSING, INFORMATICS, COMMUNICATION AND ENERGY SYSTEMS (SPICES), 2015,
  • [35] A Non-Invasive Method of Monitoring Glucose in Blood Using a Planar Yagi-Uda Antenna and Microstrip Filter
    Nella, Anveshkumar
    Aldhaheri, Rabah Wasel
    Kamili, Jagadeesh Babu
    Sobahi, Nebras Mohammed Kamal A.
    ELEKTRONIKA IR ELEKTROTECHNIKA, 2023, 29 (01) : 33 - 39
  • [36] Non-Invasive Blood Glucose Monitoring Using Near Infrared Spectroscopy
    Gayathri, B.
    Sruthi, K.
    Menon, K. A. Unnikrishna
    2017 INTERNATIONAL CONFERENCE ON COMMUNICATION AND SIGNAL PROCESSING (ICCSP), 2017, : 1139 - 1142
  • [37] Flexible Optical Fiber Sensor for Non-Invasive Continuous Monitoring of Human Physiological Signals
    Yu, Qi
    Zhang, Ya-nan
    Jiang, Lingxiao
    Li, Linqian
    Li, Xuegang
    Zhao, Jian
    SMALL METHODS, 2025,
  • [38] Non-Invasive Blood Glucose Monitoring Device Using Photoacoustic Spectroscopy
    Jahana, Takahito
    Higa, Hiroki
    2020 5TH INTERNATIONAL CONFERENCE ON INTELLIGENT INFORMATICS AND BIOMEDICAL SCIENCES (ICIIBMS 2020), 2020, : 85 - 88
  • [39] Flexible Sphere Elastomer Structural Pressure Sensor for Non-invasive Pulse Wave Monitoring
    Zhang, Wei
    Zou, Mingjun
    Wang, Yiming
    Wang, Xiaoke
    Zhu, He
    Hu, Junfeng
    Lu, Yanpeng
    Lin, Zhiming
    ACS APPLIED ELECTRONIC MATERIALS, 2024, 6 (09) : 6665 - 6670
  • [40] Non-Invasive, Non-Enzymatic, Biodegradable and Flexible Sweat Glucose Sensor and Its Electrochemical Studies
    Ramadoss, Preethi
    Rahman, Mohammed Isfahur
    Perumal, Agilan
    Nallaiyan, Rajendran
    Basha, Sabiha Hayath
    Dakshanamoorthy, Arivuoli
    CHEMISTRYSELECT, 2020, 5 (36): : 11305 - 11321