Cap-fitted colonoscopy: a randomized, tandem colonoscopy study of adenoma miss rates

被引:101
作者
Hewett, David G. [1 ]
Rex, Douglas K. [1 ]
机构
[1] Indiana Univ Sch Med, Dept Med, Div Gastroenterol Hepatol, Indianapolis, IN USA
关键词
TRANSPARENT CAP; WITHDRAWAL TIMES; WHITE-LIGHT; NARROW-BAND; MUCOSAL RESECTION; CONTROLLED-TRIAL; WIDE-ANGLE; IMPACT; HOOD; EFFICACY;
D O I
10.1016/j.gie.2010.04.030
中图分类号
R57 [消化系及腹部疾病];
学科分类号
摘要
Background: Failures of adenoma detection diminish the effectiveness of colonoscopy. Objective: This study investigated the impact of cap-fitted colonoscopy (CFC) on the adenoma miss rate at colonoscopy. Design: Randomized, tandem colonoscopy study. Setting: University hospital. Patients: This study involved patients undergoing elective screening or surveillance colonoscopy. Intervention: Patients were randomized to undergo cap-fitted (n = 52) or regular, high-definition (n = 48) colonoscopy before undergoing a second colonoscopy by the alternate method. During CFC, a plastic cap or hood was attached to the tip of the colonoscope, which was used to flatten haustral folds and improve mucosal exposure. Main Outcome Measurements: The primary outcome measure was the miss rate for adenomas between patients who underwent CFC first and patients who underwent regular colonoscopy first. Results: A total of 238 adenomas were detected in 67 patients (67%), with a combined overall miss rate of 27.7%, comprising 66 missed adenomas in 38 patients. Patients undergoing initial CFC had a significantly lower miss rate for all adenomas compared with that of patients undergoing regular colonoscopy (21% vs 33%, P = .039). Miss rates with CFC were significantly lower for adenomas of <= 5 mm (22% vs 35%; P = .037). There was no significant difference in per-patient miss rates between the initial CFC group (51%, n = 18) and the initial regular colonoscopy group (63%, n = 20, P = .36). Limitations: Single-center study with two endoscopists. Conclusion: CFC reduces miss rates for all adenomas and specifically for small adenomas. (Clinical trial registration number: NCT00577083) (Gastrointest Endosc 2010;72:775-81.)
引用
收藏
页码:775 / 781
页数:7
相关论文
共 32 条
[31]   Polyp miss rate determined by tandem colonoscopy: A systematic review [J].
van Rijn, JC ;
Reitsma, JB ;
Stoker, J ;
Bossuyt, PM ;
van Deventer, SJ ;
Dekker, E .
AMERICAN JOURNAL OF GASTROENTEROLOGY, 2006, 101 (02) :343-350
[32]   A retrograde-viewing device improves detection of adenomas in the colon: a prospective efficacy evaluation (with videos) [J].
Waye, Jerome D. ;
Heigh, Russell I. ;
Fleischer, David E. ;
Leighton, Jonathan A. ;
Gurudu, Suryakanth ;
Aldrich, Leslie B. ;
Li, Jiayi ;
Ramrakhiani, Sanjay ;
Edmundowicz, Steven A. ;
Early, Dayna S. ;
Jonnalagadda, Sreenivasa ;
Bresalier, Robert S. ;
Kessler, William R. ;
Rex, Douglas K. .
GASTROINTESTINAL ENDOSCOPY, 2010, 71 (03) :551-556