Accident safety analysis of flow blockage in an assembly in the JRR-3M research reactor using system code RELAP5 and CFD code FLUENT

被引:16
作者
Guo, Yuchuan [1 ]
Wang, Guanbo [1 ]
Qian, Dazhi [1 ]
Yu, Heng [1 ]
Hu, Bo [1 ]
Guo, Simao [1 ]
Mi, Xiangmiao [1 ]
Ma, Jimin [1 ]
机构
[1] China Acad Engn Phys, Inst Nucl Phys & Chem, Mianyang 621900, Peoples R China
基金
中国国家自然科学基金;
关键词
Flow blockage; RELAP5/MOD3.4; FLUENT; DNB; THERMAL-HYDRAULIC ANALYSIS; COOLANT CHANNEL; TRANSIENT; CORE; FUEL;
D O I
10.1016/j.anucene.2018.08.031
中图分类号
TL [原子能技术]; O571 [原子核物理学];
学科分类号
0827 ; 082701 ;
摘要
The main purpose of the paper is to execute the thermal-hydraulic analysis of flow blockage in a single fuel assembly in the JRR-3M research reactor (Upgraded Japan Research Reactor No. 3). Using the one-dimensional system analysis code RELAP5/MOD3.4, flow region in a standard fuel assembly (SFA) is lumped into a coolant channel. 5 similar coolant channels representing 5 independent assemblies are modeled to consider the interaction between blocked channel and adjacent channels. The rest of the core is lumped into 1 average channel and 1 bypass channel. The coolant system is also modeled in detail. Meanwhile, a three-dimensional model of heated part in the assembly is built using the computational fluid dynamics (CFD) code FLUENT. Results calculated by RELAP5/MOD3.4 are used as the boundary conditions of the 3D model. The user-defined function (UDF) is adopted to describe phase change and the power distribution in axial and radial direction in the assembly. Results indicate that it is necessary for assembly blockage to consider the influence of power distribution on accident consequence. When the blockage ratio is 64%, coolant in the hottest subchannel is still supercooled while coolant temperature at outlet is close to saturation temperature. It is the critical blockage ratio to ensure the reactor safety. When the blockage ratio is 70%, departure from nucleate boiling (DNB) will occur. According to the FLUENT code, the process of bubble generation and growth is discussed. It can be found that if the bubbles largely generate, there will be obvious impacts on heat transfer of fuel plate and coolant flow. Fuel plates may damage locally. (C) 2018 Elsevier Ltd. All rights reserved.
引用
收藏
页码:125 / 136
页数:12
相关论文
共 24 条
[1]   Analysis of partial and total flow blockage of a single fuel assembly of an MTR research reator core [J].
Adorni, M ;
Bousbia-Salah, A ;
Hamidouche, T ;
Di Maro, B ;
Pierro, F ;
D'Auria, F .
ANNALS OF NUCLEAR ENERGY, 2005, 32 (15) :1679-1692
[2]   Thermal hydraulic analyses of JRR-3: Code-to-code comparison of COOLOD-N2 and TMAP [J].
Albati, Mohammad A. ;
AL-Yahia, Omar S. ;
Park, Jonghark ;
Chae, Heetaek ;
Jo, Daeseong .
PROGRESS IN NUCLEAR ENERGY, 2014, 71 :1-8
[3]  
[Anonymous], 1995, RELAP MOD3 CODE MAN, V3
[4]  
Guo Y., 2018, NUCL TECHNOL
[5]   Thermal hydraulic analysis of loss of flow accident in the JRR-3M research reactor under the flow blockage transient [J].
Guo, Yuchuan ;
Wang, Guanbo ;
Qian, Dazhi ;
Yu, Heng ;
Hu, Bo ;
Guo, Simao ;
Mi, Xiangmiao .
ANNALS OF NUCLEAR ENERGY, 2018, 118 :147-153
[6]   ANALYTICAL STUDY ON THERMAL-HYDRAULIC BEHAVIOR OF TRANSIENT FROM FORCED CIRCULATION TO NATURAL CIRCULATION IN JRR-3 [J].
HIRANO, M ;
SUDO, Y .
JOURNAL OF NUCLEAR SCIENCE AND TECHNOLOGY, 1986, 23 (04) :352-368
[7]  
Jincai Li, 1996, J NUCL SCI ENG, V16, P35
[8]  
Keller F.R., 1962, FUEL ELEMENT FLOW BL
[9]   Flow blockage accident or loss of flow accident by using comparative approach of NK/TH coupling codes and RELAP5 code [J].
Khan, Salah Ud-Din ;
Khan, Shahab Ud-Din ;
Peng, Minjun .
ANNALS OF NUCLEAR ENERGY, 2014, 64 :311-319
[10]  
Lee B., 2015, INT M RED ENR RES TE