Vertebral morphometry derived from digital images

被引:15
作者
Rosol, MS
Cohen, GL
Halpern, EF
Chew, FS
Kattapuram, SV
Palmer, WE
Dupuy, DE
Rosenthal, DI
机构
[1] MASSACHUSETTS GEN HOSP,DEPT RADIOL,BOSTON,MA 02114
[2] HARVARD UNIV,SCH MED,BOSTON,MA 02114
关键词
D O I
10.2214/ajr.167.6.8956594
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
OBJECTIVE. We describe a method for capturing measurement data directly from digitized images using specialized software and high-resolution workstations. We have evaluated the reliability, accuracy, and reproducibility of this method in an international clinical trial involving vertebral morphometry. MATERIALS AND METHODS. Accuracy was determined using clinical radiographs measured with vernier calipers and a film phantom. Intra- and interobserver variabilities were assessed, and longitudinal reproducibility was evaluated. As part of the trial, spinal radiographs were collected from more than 200 international health care facilities and digitized at four screening centers. Digitized images were stored and sent to our central facility for morphometry and archiving. Timeliness and variability of the process were tracked. RESULTS. Relative accuracy was nearly 100%. Correlation with clinical measurements was high (r = .96; p < .05). The mean coefficient of variation for interobserver variability was 2%. Intraobserver variation was 3-5%. The coefficient of variation for longitudinal reproducibility ranged from 4% to 6%. After 9 months of operation, our trial included 9494 patients. Of approximately 36,000 radiographs, 98% passed quality review. Only 1% of vertebral levels were not measurable. Hardware and software problems were minimal. CONCLUSION. The use of digitized images for morphometry is accurate, reproducible, and convenient. When applied to a large-scale clinical trial, it offers unique advantages that may justify the cost and complexity that exceed those of conventional radiographs.
引用
收藏
页码:1545 / 1549
页数:5
相关论文
共 19 条
  • [1] BLACK DM, 1991, J BONE MINER RES, V6, P883
  • [2] DAVIES KM, 1989, J BONE MINER RES, V4, P341
  • [3] ACCURACY OF VOLUME MEASUREMENTS OF COMPUTED-TOMOGRAPHY AND MAGNETIC-RESONANCE-IMAGING PHANTOMS BY 3-DIMENSIONAL RECONSTRUCTION AND PRELIMINARY CLINICAL-APPLICATION
    DISLER, DG
    MARR, DS
    ROSENTHAL, DI
    [J]. INVESTIGATIVE RADIOLOGY, 1994, 29 (08) : 739 - 745
  • [4] EASTELL R, 1991, J BONE MINER RES, V6, P207
  • [5] ETTINGER B, 1992, J BONE MINER RES, V7, P449
  • [6] GALLAGHER JC, 1988, BONE MINER, V4, P189
  • [7] BONE-MINERAL MASS ASSOCIATED WITH POSTMENOPAUSAL VERTEBRAL DEFORMITIES
    HARRISON, JE
    PATT, N
    MULLER, C
    BAYLEY, TA
    BUDDEN, FH
    JOSSE, RG
    MURRAY, TM
    STURTRIDGE, WC
    STRAUSS, A
    GOODWIN, S
    [J]. BONE AND MINERAL, 1990, 10 (03): : 243 - 251
  • [8] VERTEBRAL MORPHOMETRY IN DIAGNOSIS OF SPINAL FRACTURES
    HEDLUND, LR
    GALLAGHER, JC
    [J]. BONE AND MINERAL, 1988, 5 (01): : 59 - 67
  • [9] MEASUREMENT OF ANTERIOR VERTEBRAL COMPRESSIONS AND BICONCAVE VERTEBRAE
    HURXTHAL, LM
    [J]. AMERICAN JOURNAL OF ROENTGENOLOGY RADIUM THERAPY AND NUCLEAR MEDICINE, 1968, 103 (03): : 635 - &
  • [10] THE ASSESSMENT OF VERTEBRAL DEFORMITY - A METHOD FOR USE IN POPULATION STUDIES AND CLINICAL-TRIALS
    MCCLOSKEY, EV
    SPECTOR, TD
    EYRES, KS
    FERN, ED
    OROURKE, N
    VASIKARAN, S
    KANIS, JA
    [J]. OSTEOPOROSIS INTERNATIONAL, 1993, 3 (03) : 138 - 147