The Evolution of Echocardiographic Type and Anesthetic Technique for Transcatheter Aortic Valve Replacement at a High-Volume Transcatheter Aortic Valve Replacement Center

被引:6
作者
Marino, Morgan [1 ]
Lilie, Craig J. [1 ]
Culp, William C., Jr. [1 ]
Schepel, Shawn R. [1 ]
Tippett, Jason C. [1 ]
机构
[1] Texas A&M Univ, Coll Med, Hlth Sci Ctr, Dept Anesthesiol,Baylor Scott & White Med Ctr Tem, MS-20-D304,2401 S 31st St, Temple, TX 76508 USA
关键词
aortic valve stenosis; transcatheter aortic valve replacement; echocardiography; transesophageal echocardiography; transthoracic echocardiography; THORACIC SURGEONS/AMERICAN COLLEGE; TRANSESOPHAGEAL ECHOCARDIOGRAPHY; TRANSTHORACIC ECHOCARDIOGRAPHY; PARAVALVULAR REGURGITATION; MAGNETIC-RESONANCE; GENERAL-ANESTHESIA; OUTCOMES; IMPLANTATION; TAVR; GUIDANCE;
D O I
10.1053/j.jvca.2018.06.022
中图分类号
R614 [麻醉学];
学科分类号
100217 ;
摘要
Objective: Describe the change in intraoperative transcatheter aortic valve replacement (TAVR) care by examining the utilization of transesophageal echocardiography (TEE) versus transthoracic echocardiography (TTE) and general anesthesia (GA) versus conscious sedation (CS) over time. Design: Retrospective, observational. Setting: A university, single, high-volume TAVR center. Participants: Patients who underwent TAVR. Interventions: Retrospective data collection from the electronic medical records on TAVR patients at a single institution from March 1, 2014 to August 31, 2017. The intraoperative echocardiographic modality, anesthetic type, Society of Thoracic Surgeons (STS) operative mortality risk score, and date each new TAVR valve first was employed at the institution were recorded. Measurements and Main Results: Data were analyzed using descriptive statistics apportioned into 6-month intervals. The Fisher exact test and chi-square test were used to test the association of anesthesia type and echocardiography over time, respectively. STS score, anesthetic type, and echocardiographic type were compared using the Wilcoxon rank sum test. Analysis showed increased use of TTE and CS, from 0% and 0% intially to 68.42% and 63.16% most recently (p < 0.0001). In the final study period (after March 1, 2017), the use of TTE and CS surpassed TEE and GA, respectively. STS scores were significantly higher among patients having TEE versus TTE (median STS 6.34 v 4.45, respectively [p = 0.0047]) and GA versus CS (median STS 6.36 v 4.37, respectively [p = 0.0090]). Conclusion: Although TAVR initially was conducted exclusively under GA with TEE, nearly two-thirds of TAVR procedures now are performed using CS and TTE at the authors' institution. STS scores were significantly lower in patients having CS and TTE. (C) 2018 Elsevier Inc. All rights reserved.
引用
收藏
页码:29 / 35
页数:7
相关论文
共 36 条
  • [1] Comparison of Two- and Three-Dimensional Transthoracic Echocardiography to Cardiac Magnetic Resonance Imaging for Assessment of Paravalvular Regurgitation After Transcatheter Aortic Valve Implantation
    Altiok, Ertunc
    Frick, Michael
    Meyer, Christian G.
    Al Ateah, Ghazi
    Napp, Andreas
    Kirschfink, Annemarie
    Almalla, Mohammad
    Lotfi, Shahran
    Becker, Michael
    Herich, Lena
    Lehmacher, Walter
    Hoffmann, Rainer
    [J]. AMERICAN JOURNAL OF CARDIOLOGY, 2014, 113 (11) : 1859 - 1866
  • [2] Incidence, Predictors, and Outcomes of Aortic Regurgitation After Transcatheter Aortic Valve Replacement Meta-Analysis and Systematic Review of Literature
    Athappan, Ganesh
    Patvardhan, Eshan
    Tuzcu, E. Murat
    Svensson, Lars Georg
    Lemos, Pedro A.
    Fraccaro, Chiara
    Tarantini, Giuseppe
    Sinning, Jan-Malte
    Nickenig, Georg
    Capodanno, Davide
    Tamburino, Corrado
    Latib, Azeem
    Colombo, Antonio
    Kapadia, Samir R.
    [J]. JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2013, 61 (15) : 1585 - 1595
  • [3] Comparison of Transfemoral Transcatheter Aortic Valve Replacement Performed in the Catheterization Laboratory (Minimalist Approach) Versus Hybrid Operating Room (Standard Approach) Outcomes and Cost Analysis
    Babaliaros, Vasilis
    Devireddy, Chandan
    Lerakis, Stamatios
    Leonardi, Robert
    Iturra, Sebastian A.
    Mavromatis, Kreton
    Leshnower, Bradley G.
    Guyton, Robert A.
    Kanitkar, Mihir
    Keegan, Patricia
    Simone, Amy
    Stewart, James P.
    Ghasemzadeh, Nima
    Block, Peter
    Thourani, Vinod H.
    [J]. JACC-CARDIOVASCULAR INTERVENTIONS, 2014, 7 (08) : 898 - 904
  • [4] Evolution of Transcatheter Aortic Valve Replacement
    Bourantas, Christos V.
    Serruys, Patrick W.
    [J]. CIRCULATION RESEARCH, 2014, 114 (06) : 1037 - 1051
  • [5] Are Transthoracic and Transesophageal Echocardiography Equal "PARTNERS" in the Assessment of Paravalvular Leak After TAVR?
    Capdeville, Michelle
    Alfirevic, Andrej
    [J]. JOURNAL OF CARDIOTHORACIC AND VASCULAR ANESTHESIA, 2017, 31 (04) : 1285 - 1289
  • [6] Procedural Experience for Transcatheter Aortic Valve Replacement and Relation to Outcomes The STS/ACC TVT Registry
    Carroll, John D.
    Vemulapalli, Sreekanth
    Dai, Dadi
    Matsouaka, Roland
    Blackstone, Eugene
    Edwards, Fred
    Masoudi, Frederick A.
    Mack, Michael
    Peterson, Eric D.
    Holmes, David
    Rumsfeld, John S.
    Tuzcu, E. Murat
    Grover, Frederick
    [J]. JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2017, 70 (01) : 29 - 41
  • [7] Outcomes and Predictors of Mortality After Transcatheter Aortic Valve Implantation: Results of the Brazilian Registry
    de Brito, Fabio S., Jr.
    Carvalho, Luiz A.
    Sarmento-Leite, Rogerio
    Mangione, Jose A.
    Lemos, Pedro
    Siciliano, Alexandre
    Caramori, Paulo
    Thiago, Luiz Sao
    Grube, Eberhard
    Abizaid, Alexandre
    [J]. CATHETERIZATION AND CARDIOVASCULAR INTERVENTIONS, 2015, 85 (05) : E153 - E162
  • [8] The development of transcatheter aortic valve replacement in the USA
    Dvir, Danny
    Barbash, Israel M.
    Ben-Dor, Itsik
    Okubagzi, Petros
    Satler, Lowell F.
    Waksman, Ron
    Pichard, Augusto D.
    [J]. ARCHIVES OF CARDIOVASCULAR DISEASES, 2012, 105 (03) : 160 - 164
  • [9] Efficacy and safety of transcatheter aortic valve replacement in aortic stenosis patients at low to moderate surgical risk: a comprehensive meta-analysis
    Elmaraezy, Ahmed
    Ismail, Ammar
    Abushouk, Abdelrahman Ibrahim
    Eltoomy, Moutaz
    Saad, Soha
    Negida, Ahmed
    Abdelaty, Osama Mahmoud
    Abdallah, Ahmed Ramadan
    Aboelfotoh, Ahmed Magdy
    Hassan, Hossam Mahmoud
    Elmaraezy, Aya Gamal
    Morsi, Mahmoud
    Althaher, Farah
    Althaher, Moath
    AlSafadi, Ammar M.
    [J]. BMC CARDIOVASCULAR DISORDERS, 2017, 17
  • [10] Local versus general anesthesia for transcatheter aortic valve implantation (TAVR) - systematic review and meta-analysis
    Froehlich, Georg M.
    Lansky, Alexandra J.
    Webb, John
    Roffi, Marco
    Toggweiler, Stefan
    Reinthaler, Markus
    Wang, Duolao
    Hutchinson, Nevil
    Wendler, Olaf
    Hildick-Smith, David
    Meier, Pascal
    [J]. BMC MEDICINE, 2014, 12