The determination of frying oil quality using Fourier transform infrared attenuated total reflectance

被引:66
|
作者
Innawong, B
Mallikarjunan, P
Irudayaraj, J
Marcy, JE
机构
[1] Virginia Polytech Inst & State Univ, Dept Biol Syst Engn, Blacksburg, VA 24061 USA
[2] Penn State Univ, Dept Agr & Biol Engn, University Pk, PA 16802 USA
[3] Virginia Polytech Inst & State Univ, Dept Food Sci & Technol, Blacksburg, VA 24061 USA
关键词
FTIR-ATR; frying oil quality; dielectric constant; free fatty acid content; peroxide value;
D O I
10.1016/S0023-6438(03)00120-8
中图分类号
TS2 [食品工业];
学科分类号
0832 ;
摘要
The possibility of using the whole spectra (wave numbers between 4000 and 850 cm(-1)) from Fourier transform infrared attenuated total reflectance spectroscopy (FTIR-ATR) to differentiate between good, marginal and unacceptable oils with regard to various intensities of oil rancidity was investigated. Fresh, used, and discarded oils were collected from several fast food restaurants from each frying cycle for 4 weeks. Dielectric constant, peroxide value, free fatty acid content, and density of oil samples significantly (P<0.01) increased with frying time. The correlation (r) between FTIR absorbance at 3300 cm(-1) and free fatty acid content was from 0.84 to 0.94 for oils from the three restaurants. Similarly, the correlation between FTIR absorbance at 3471 cm(-1) and peroxide value was from 0.90 to 0.97. The results of principal component analysis using the whole spectra (4000-850 cm(-1)) showed good discrimination and stability for identification between acceptable, marginal and unacceptable frying oils. (C) 2003 Swiss Society of Food Science and Technology. Published by Elsevier Ltd. All rights reserved.
引用
收藏
页码:23 / 28
页数:6
相关论文
共 50 条
  • [1] Determination of quality parameters of beers by the use of attenuated total reflectance-Fourier transform infrared spectroscopy
    Llario, R
    Iñón, FA
    Garrigues, S
    de la Guardia, M
    TALANTA, 2006, 69 (02) : 469 - 480
  • [2] Direct determination of polymerized triglycerides in deep-frying olive oil by attenuated total reflectance–Fourier transform infrared spectroscopy using partial least squares regression
    Julia Kuligowski
    Guillermo Quintás
    Salvador Garrigues
    Miguel de la Guardia
    Analytical and Bioanalytical Chemistry, 2010, 397 : 861 - 869
  • [3] Direct determination of total isothiocyanate content in broccoli using attenuated total reflectance infrared Fourier transform spectroscopy
    Revelou, P. K.
    Kokotou, M. G.
    Pappas, C. S.
    Constantinou-Kokotou, V.
    JOURNAL OF FOOD COMPOSITION AND ANALYSIS, 2017, 61 : 47 - 51
  • [4] Determination of calcium carbonate in limestone by attenuated total reflectance Fourier transform infrared spectrometry
    Lee, SH
    Bae, ZU
    Kim, KW
    Yang, DK
    Choi, SS
    ANALYTICAL SCIENCES, 1997, 13 : 93 - 96
  • [5] Determination of liquid egg composition using attenuated total reflectance Fourier transform infrared spectroscopy and chemometrics
    Uysal, Reyhan S.
    Yilmaz, Ozay Mentes
    Boyaci, Ismail H.
    JOURNAL OF THE SCIENCE OF FOOD AND AGRICULTURE, 2019, 99 (07) : 3572 - 3577
  • [6] Direct determination of polymerized triglycerides in deep-frying olive oil by attenuated total reflectance-Fourier transform infrared spectroscopy using partial least squares regression
    Kuligowski, Julia
    Quintas, Guillermo
    Garrigues, Salvador
    de la Guardia, Miguel
    ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2010, 397 (02) : 861 - 869
  • [7] Sulfur and Total Carboxylic Acid Number Determination in Vacuum Gas Oil by Attenuated Total Reflectance Fourier Transform Infrared Spectroscopy
    Chakravarthy, Ramachandra
    Paramati, Manjula
    Savalia, Anilkumar
    Verma, Anurag
    Das, Asit Kumar
    Saravanan, Chandra
    Gudasi, Kalagouda B.
    ENERGY & FUELS, 2018, 32 (02) : 2128 - 2136
  • [8] Study of prepolymer stability using attenuated total reflectance Fourier transform infrared spectroscopy
    Strohecker, Sarah A.
    Kneas, Kristi A.
    Obetz, David
    ABSTRACTS OF PAPERS OF THE AMERICAN CHEMICAL SOCIETY, 2012, 243
  • [9] Determination of cholesterol concentration in human milk samples using attenuated total reflectance Fourier transform infrared spectroscopy
    Kamelska, A. M.
    Pietrzak-Fiecko, R.
    Bryl, K.
    JOURNAL OF APPLIED SPECTROSCOPY, 2013, 80 (01) : 148 - 152
  • [10] Determination of cholesterol concentration in human milk samples using attenuated total reflectance Fourier transform infrared spectroscopy
    A. M. Kamelska
    R. Pietrzak-Fiećko
    K. Bryl
    Journal of Applied Spectroscopy, 2013, 80 : 148 - 152