Metal artefact reduction in MRI at both 1.5 and 3.0 T using slice encoding for metal artefact correction and view angle tilting

被引:31
作者
Reichert, M. [1 ]
Ai, T. [2 ]
Morelli, J. N. [3 ]
Nittka, M. [4 ]
Attenberger, U. [1 ]
Runge, V. M. [5 ]
机构
[1] Heidelberg Univ, Univ Med Ctr Mannheim, Med Fac Mannheim, Dept Clin Radiol & Nucl Med, Mannheim, Germany
[2] Huazhong Univ Sci & Technol, Tongji Hosp, Tongji Med Coll, Dept Radiol, Wuhan 430074, Hubei, Peoples R China
[3] Johns Hopkins Univ, Sch Med, Russell H Morgan Dept Radiol & Radiol Sci, Baltimore, MD USA
[4] Siemens Healthcare Sect, Applicat Dev, Erlangen, Germany
[5] Univ Zurich Hosp, Inst Diagnost & Intervent Radiol, CH-8091 Zurich, Switzerland
关键词
TOTAL HIP-ARTHROPLASTY; SEMAC; IMPLANTS; SUSCEPTIBILITY; 3-T;
D O I
10.1259/bjr.20140601
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Objective: To compare metal artefact reduction in MRI at both 3.0 T and 1.5 T using different sequence strategies. Methods: Metal implants of stainless steel screw and plate within agarose phantoms and tissue specimens as well as three patients with implants were imaged at both 1.5 T and 3.0 T, using view angle tilting (VAT), slice encoding for metal artefact correction with VAT (SEMAC-VAT) and conventional sequence. Artefact reduction in agarose phantoms was quantitatively assessed by artefact volume measurements. Blinded reads were conducted in tissue specimen and human imaging, with respect to artefact size, distortion, blurring and overall image quality. Wilcoxon and Friedman tests for multiple comparisons and intraclass correlation coefficient (ICC) for interobserver agreement were performed with a significant level of p<0.05. Results: Compared with conventional sequences, SEMAC-VAT significantly reduced metal artefacts by 83%+/- 9% for the screw and 89% +/- 3% for the plate at 1.5T; 72% +/- 7% for the screw and 38% +/- 13% for the plate at 3.0T (p<0.05). In qualitative analysis, SEMAC-VAT allowed for better visualization of tissue structures adjacent to the implants and produced better overall image quality with good interobserver agreement for both tissue specimen and human imaging (ICC50.80-0.99; p, 0.001). In addition, VAT also markedly reduced metal artefacts compared with conventional sequence, but was inferior to SEMAC-VAT. Conclusion: SEMAC-VAT and VAT techniques effectively reduce artefacts from metal implants relative to conventional imaging at both 1.5 T and 3.0 T. Advances in knowledge: The feasibility of metal artefact reduction with SEMAC-VAT was demonstrated at 3.0-T MR. SEMAC-VAT significantly reduced metal artefacts at both 1.5 and 3.0 T. SEMAC-VAT allowed for better visualization of the tissue structures adjacent to the metal implants. SEMAC-VAT produced consistently better image quality in both tissue specimen and human imaging.
引用
收藏
页数:11
相关论文
共 24 条
  • [1] SEMAC-VAT and MSVAT-SPACE Sequence Strategies for Metal Artifact Reduction in 1.5T Magnetic Resonance Imaging
    Ai, Tao
    Padua, Abraham
    Goerner, Frank
    Nittka, Mathias
    Gugala, Zbigniew
    Jadhav, Siddharth
    Trelles, Miguel
    Johnson, Raleigh F.
    Lindsey, Ronald W.
    Li, Xiaoming
    Runge, Val M.
    [J]. INVESTIGATIVE RADIOLOGY, 2012, 47 (05) : 267 - 276
  • [2] Influence on Flux Density of Intraoral Dental Magnets During 1.5 and 3.0 Tesla MRI
    Blankenstein, F. H.
    Truong, B.
    Thomas, A.
    Boeckler, A.
    Peroz, I.
    [J]. ROFO-FORTSCHRITTE AUF DEM GEBIET DER RONTGENSTRAHLEN UND DER BILDGEBENDEN VERFAHREN, 2011, 183 (08): : 727 - 734
  • [3] Reduction of blurring in view angle tilting MRI
    Butts, K
    Pauly, JM
    Gold, GE
    [J]. MAGNETIC RESONANCE IN MEDICINE, 2005, 53 (02) : 418 - 424
  • [4] New MR Imaging Methods for Metallic Implants in the Knee: Artifact Correction and Clinical Impact
    Chen, Christina A.
    Chen, Weitian
    Goodman, Stuart B.
    Hargreaves, Brian A.
    Koch, Kevin M.
    Lu, Wenmaio
    Brau, Anja C.
    Draper, Christine E.
    Delp, Scott L.
    Gold, Garry E.
    [J]. JOURNAL OF MAGNETIC RESONANCE IMAGING, 2011, 33 (05) : 1121 - 1127
  • [5] TOTAL INHOMOGENEITY CORRECTION INCLUDING CHEMICAL-SHIFTS AND SUSCEPTIBILITY BY VIEW ANGLE TILTING
    CHO, ZH
    KIM, DJ
    KIM, YK
    [J]. MEDICAL PHYSICS, 1988, 15 (01) : 7 - 11
  • [6] Imaging of Soft Tissues Adjacent to Orthopedic Hardware: Comparison of 3-T and 1.5-T MRI
    Farrelly, Cormac
    Davarpanah, Amir
    Brennan, Stephen
    Sampson, Mathew
    Eustace, Stephen J.
    [J]. AMERICAN JOURNAL OF ROENTGENOLOGY, 2010, 194 (01) : W60 - W64
  • [7] Garvin Kevin L, 2012, Instr Course Lect, V61, P411
  • [8] MRI After Arthroplasty: Comparison of MAVRIC and Conventional Fast Spin-Echo Techniques
    Hayter, Catherine L.
    Koff, Matthew F.
    Shah, Parina
    Koch, Kevin M.
    Miller, Theodore T.
    Potter, Hollis G.
    [J]. AMERICAN JOURNAL OF ROENTGENOLOGY, 2011, 197 (03) : W405 - W411
  • [9] MRI analysis of the component-bone interface after TKA
    Heyse, Thomas J.
    Chong, Le Roy
    Davis, Jack
    Boettner, Friedrich
    Haas, Steven B.
    Potter, Hollis G.
    [J]. KNEE, 2012, 19 (04) : 290 - 294
  • [10] The painful knee after TKA: a diagnostic algorithm for failure analysis
    Hofmann, S.
    Seitlinger, G.
    Djahani, O.
    Pietsch, M.
    [J]. KNEE SURGERY SPORTS TRAUMATOLOGY ARTHROSCOPY, 2011, 19 (09) : 1442 - 1452