Evaluation of the methods used for carboxyhemoglobin analysis in postmortem blood

被引:28
作者
Boumba, VA [1 ]
Vougiouklakis, T [1 ]
机构
[1] Univ Ioannina, Sch Med, Dept Forens Med & Toxicol, GR-45110 Ioannina, Greece
关键词
carboxyhemoglobin; comparison; forensic toxicology; gas chromatography; postmortem blood; spectrophotometry;
D O I
10.1080/10915810591007256
中图分类号
R9 [药学];
学科分类号
1007 ;
摘要
Numerous methods have been described in the literature for the determination of carboxyhemoglobin (COHb) in whole blood. The most popular and widely used have been (1) the spectrophotometric methods, which could be performed either by using a conventional spectrophotometer or by using specialized automated instruments known as CO-oximeters; (2) the gas chromatographic methods, with variable detection systems, which have been considered as the reference methods for every carbon monoxide analysis. The authors have critically reviewed previously reported comparative studies on these methods, considering statistical and analytical matters, in order to propose the best method for the determination of COHb in postmortem blood, that could be utilized in forensic toxicology laboratories where such analyses are limited in number (less than 20 per year). Criteria for evaluation have been accuracy, reliability, simplicity, time, and cost. The authors' concluding statement has been that the manual spectrophotometric method could be the method of choice for COHb determination in postmortem blood samples. It is simple, rapid, and reliable and fulfills the forensically acceptable accuracy. It is performed by the use of a conventional spectrophotometer, which is considered a basic instrument in every analytical laboratory.
引用
收藏
页码:275 / 281
页数:7
相关论文
共 60 条
[21]   Degree of atherosclerosis predicts short-term commitment for smoking cessation therapy [J].
Hirschl, M ;
Francesconi, C ;
Chudik, M ;
Katzenschlager, R ;
Kundi, M .
PREVENTIVE MEDICINE, 2004, 39 (01) :142-146
[22]   A GAS-CHROMATOGRAPHIC INTEGRATOR PROCEDURE FOR THE DETERMINATION OF CARBOXYHEMOGLOBIN PERCENT SATURATION IN POSTMORTEM SAMPLES [J].
HOBBS, LD ;
JACHIMCZYK, JA ;
SCHLOEGEL, EL .
JOURNAL OF ANALYTICAL TOXICOLOGY, 1980, 4 (04) :181-184
[23]   DIABETIC KETOACIDOSIS APPEARING AS CARBON-MONOXIDE POISONING [J].
HODGKIN, JE ;
CHAN, DM .
JAMA-JOURNAL OF THE AMERICAN MEDICAL ASSOCIATION, 1975, 231 (11) :1164-1165
[24]  
Horvath SM, 1942, J BIOL CHEM, V144, P747
[25]  
HORVATH SM, 1988, RES REP HLTH EFF I, V21, P1
[26]   MEASUREMENT OF CARBOXYHEMOGLOBIN BY SPECTROPHOTOMETRY AND GAS-CHROMATOGRAPHY [J].
JOHANSSON, MB ;
WOLLMER, P .
CLINICAL PHYSIOLOGY, 1989, 9 (06) :581-586
[27]   Determination of carbon monoxide, methane and carbon dioxide in refinery hydrogen gases and air by gas chromatography [J].
Kaminski, M ;
Kartanowicz, R ;
Jastrzebski, D ;
Kaminski, MM .
JOURNAL OF CHROMATOGRAPHY A, 2003, 989 (02) :277-283
[28]  
KATSUMATA Y, 1982, J FORENSIC SCI, V27, P928
[29]  
KATSUMATA Y, 1985, HANZALGAKU ZAASH, V61, P139
[30]  
KLIMISCH HJ, 1974, Z KLIN CHEM KLIN BIO, V12, P535