Evaluation of the methods used for carboxyhemoglobin analysis in postmortem blood

被引:28
作者
Boumba, VA [1 ]
Vougiouklakis, T [1 ]
机构
[1] Univ Ioannina, Sch Med, Dept Forens Med & Toxicol, GR-45110 Ioannina, Greece
关键词
carboxyhemoglobin; comparison; forensic toxicology; gas chromatography; postmortem blood; spectrophotometry;
D O I
10.1080/10915810591007256
中图分类号
R9 [药学];
学科分类号
1007 ;
摘要
Numerous methods have been described in the literature for the determination of carboxyhemoglobin (COHb) in whole blood. The most popular and widely used have been (1) the spectrophotometric methods, which could be performed either by using a conventional spectrophotometer or by using specialized automated instruments known as CO-oximeters; (2) the gas chromatographic methods, with variable detection systems, which have been considered as the reference methods for every carbon monoxide analysis. The authors have critically reviewed previously reported comparative studies on these methods, considering statistical and analytical matters, in order to propose the best method for the determination of COHb in postmortem blood, that could be utilized in forensic toxicology laboratories where such analyses are limited in number (less than 20 per year). Criteria for evaluation have been accuracy, reliability, simplicity, time, and cost. The authors' concluding statement has been that the manual spectrophotometric method could be the method of choice for COHb determination in postmortem blood samples. It is simple, rapid, and reliable and fulfills the forensically acceptable accuracy. It is performed by the use of a conventional spectrophotometer, which is considered a basic instrument in every analytical laboratory.
引用
收藏
页码:275 / 281
页数:7
相关论文
共 60 条
[1]   EFFECTS OF CARBON-MONOXIDE ON MYOCARDIAL-ISCHEMIA [J].
ALLRED, EN ;
BLEECKER, ER ;
CHAITMAN, BR ;
DAHMS, TE ;
GOTTLIEB, SO ;
HACKNEY, JD ;
PAGANO, M ;
SELVESTER, RH ;
WALDEN, SM ;
WARREN, J .
ENVIRONMENTAL HEALTH PERSPECTIVES, 1991, 91 :89-132
[2]  
ALLRED EN, 1999, RES REP HLTH EFF I, V25, P1
[3]   METHODS DEVELOPED FOR MASS SAMPLING ANALYSIS OF CO AND CARBOXYHEMOGLOBIN IN MAN [J].
BARETTA, ED ;
STEWART, RD ;
GRAFF, SA ;
DONAHOO, KK .
AMERICAN INDUSTRIAL HYGIENE ASSOCIATION JOURNAL, 1978, 39 (03) :202-209
[4]   SIMPLE GAS CHROMATOGRAPH WITH AN ELECTROCHEMICAL DETECTOR FOR MEASUREMENT OF HYDROGEN AND CARBON-MONOXIDE IN PARTS PER MILLION RANGE, APPLIED TO EXHALED AIR [J].
BERGMAN, I ;
COLEMAN, JE ;
EVANS, D .
CHROMATOGRAPHIA, 1975, 8 (10) :581-583
[5]   DETERMINATION OF CARBON MONOXIDE IN BLOOD AND TISSUE [J].
BLACKMORE, DJ .
ANALYST, 1970, 95 (1130) :439-+
[6]   Rapid determination of carboxyhemoglobin in blood by Oximeter [J].
Brehmer, C ;
Iten, PX .
FORENSIC SCIENCE INTERNATIONAL, 2003, 133 (1-2) :179-181
[8]   Simultaneous measurement of total hemoglobin and its derivatives in blood using CO-oximeters: Analytical principles; Their application in selecting analytical wavelengths and reference methods; A comparison of the results of the choices made [J].
Brunelle, JA ;
Degtiarov, AM ;
Moran, RF ;
Race, LA .
SCANDINAVIAN JOURNAL OF CLINICAL & LABORATORY INVESTIGATION, 1996, 56 :47-69
[9]  
Canfield DV, 1999, J FORENSIC SCI, V44, P409
[10]  
Contostavlos Dimitri L, 2003, J Clin Forensic Med, V10, P77, DOI 10.1016/S1353-1131(03)00005-1