Pt modified carbon fiber microelectrode for electrochemically catalytic reduction of hydrogen peroxide and its application in living cell H2O2 detection

被引:31
作者
Chen, Yun [1 ]
Li, Qiwei [1 ]
Jiang, Hui [1 ]
Wang, Xuemei [1 ]
机构
[1] Southeast Univ, Sch Biol Sci & Med Engn, Chien Shiung Wu Lab, State Key Lab Bioelect, Nanjing 210096, Jiangsu, Peoples R China
基金
中国国家自然科学基金;
关键词
Carbon fiber microelectrode (CFME); Electrochemical deposition; Hydrogen peroxide (H2O2); Living cell measurement; SCAN CYCLIC VOLTAMMETRY; OXIDATIVE STRESS; PARKINSONS-DISEASE; GRAPHENE; DOPAMINE; OXYGEN; ELECTRODE; RADICALS; DAMAGE;
D O I
10.1016/j.jelechem.2016.06.020
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
In this contribution, a new carbon fiber microelectrode (CFME) for detection of hydrogen peroxide (H2O2) is constructed with a rapid and low-cost method based on the electrochemical etching technique and the electro-deposition of platinum (Pt) nanoparticles, and the potential application in electrochemical bioanalysis has been explored. It is observed that when the CFME modified in 5 mmol/L chloroplatinic acid with 0.5 mol/L H2SO4 used as supporting electrolyte, the as-prepared Pt modified carbon fiber microelectrode (Pt/CFME) demonstrates an excellent electrochemically catalytic activity, which exhibited a wide linear in relevant detection for the reduction of H2O2, ranging from 0.044 to 12.30 mmol/L with the limit of 44 mu mol/L. Moreover, our results illustrate that the Pt/CFME electrode can be readily utilized in scanning electrochemical microscope (SECM) studies to detect H2O2 release from human glioblastoma cells U87 when stimulated with ascorbic acid (AA). (C) 2016 Elsevier B.V. All rights reserved.
引用
收藏
页码:233 / 237
页数:5
相关论文
共 35 条
[1]   Real-Time Monitoring of Oxidative Burst from Single Plant Protoplasts Using Microelectrochemical Sensors Modified by Platinum Nanoparticles [J].
Ai, Feng ;
Chen, Hong ;
Zhang, Shu-Hui ;
Liu, Sheng-Yi ;
Wei, Fang ;
Dong, Xu-Yan ;
Cheng, Jie-Ke ;
Huang, Wei-Hua .
ANALYTICAL CHEMISTRY, 2009, 81 (20) :8453-8458
[2]   Oxidative Stress in the Progression of Alzheimer Disease in the Frontal Cortex [J].
Ansari, Mubeen A. ;
Scheff, Stephen W. .
JOURNAL OF NEUROPATHOLOGY AND EXPERIMENTAL NEUROLOGY, 2010, 69 (02) :155-167
[3]   HYDROGEN-PEROXIDE MEDIATES AMYLOID-BETA PROTEIN TOXICITY [J].
BEHL, C ;
DAVIS, JB ;
LESLEY, R ;
SCHUBERT, D .
CELL, 1994, 77 (06) :817-827
[4]   Reactive oxygen species: from health to disease [J].
Brieger, Katharine ;
Schiavone, Stefania ;
Miller, Francis J., Jr. ;
Krause, Karl-Heinz .
SWISS MEDICAL WEEKLY, 2012, 142
[5]   Layer-by-layer assembly of graphene, Au and poly(toluidine blue O) films sensor for evaluation of oxidative stress of tumor cells elicited by hydrogen peroxide [J].
Chang, Hucheng ;
Wang, Xuemei ;
Shiu, Kowk-Keung ;
Zhu, Yanliang ;
Wang, Jianling ;
Li, Qiwei ;
Chen, Baoan ;
Jiang, Hui .
BIOSENSORS & BIOELECTRONICS, 2013, 41 :789-794
[6]   Silver-Nafion coated cylindrical carbon fiber microelectrode for amperometric monitoring of hydrogen peroxide heterogeneous catalytic decomposition [J].
Halouzka, Vladimir ;
Jakubec, Petr ;
Gregor, Cenek ;
Jancik, Dalibor ;
Papadopoulos, Kyriakos ;
Triantis, Theodor ;
Hrbac, Jan .
CHEMICAL ENGINEERING JOURNAL, 2010, 165 (03) :813-818
[7]   An electroenzymatic L-glutamate microbiosensor selective against dopamine [J].
Hamdi, Naser ;
Wang, Jianjun ;
Walker, Eric ;
Maidment, Nigel T. ;
Monbouquette, Harold G. .
JOURNAL OF ELECTROANALYTICAL CHEMISTRY, 2006, 591 (01) :33-40
[8]   Electrochemical biosensing platforms using platinum nanoparticles and carbon nanotubes [J].
Hrapovic, S ;
Liu, YL ;
Male, KB ;
Luong, JHT .
ANALYTICAL CHEMISTRY, 2004, 76 (04) :1083-1088
[9]   Carbon-fiber microelectrodes for in vivo applications [J].
Huffman, Megan L. ;
Venton, B. Jill .
ANALYST, 2009, 134 (01) :18-24
[10]   Oxidative stress in Parkinson's disease [J].
Jenner, P .
ANNALS OF NEUROLOGY, 2003, 53 :S26-S36