Technology insight: PET and PET/CT in head and neck tumor staging and radiation therapy planning
被引:22
作者:
Frank, SJ
论文数: 0引用数: 0
h-index: 0
机构:Univ Texas, MD Anderson Canc Ctr, Div Radiat Oncol, Houston, TX 77030 USA
Frank, SJ
Chao, KSC
论文数: 0引用数: 0
h-index: 0
机构:Univ Texas, MD Anderson Canc Ctr, Div Radiat Oncol, Houston, TX 77030 USA
Chao, KSC
Schwartz, DL
论文数: 0引用数: 0
h-index: 0
机构:Univ Texas, MD Anderson Canc Ctr, Div Radiat Oncol, Houston, TX 77030 USA
Schwartz, DL
Weber, RS
论文数: 0引用数: 0
h-index: 0
机构:Univ Texas, MD Anderson Canc Ctr, Div Radiat Oncol, Houston, TX 77030 USA
Weber, RS
Apisarnthanarax, S
论文数: 0引用数: 0
h-index: 0
机构:Univ Texas, MD Anderson Canc Ctr, Div Radiat Oncol, Houston, TX 77030 USA
Apisarnthanarax, S
Macapinlac, HA
论文数: 0引用数: 0
h-index: 0
机构:Univ Texas, MD Anderson Canc Ctr, Div Radiat Oncol, Houston, TX 77030 USA
Macapinlac, HA
机构:
[1] Univ Texas, MD Anderson Canc Ctr, Div Radiat Oncol, Houston, TX 77030 USA
[2] Univ Texas, MD Anderson Canc Ctr, Dept Head & Neck Surg, Houston, TX 77030 USA
[3] Univ Texas, MD Anderson Canc Ctr, Dept Expt Radiat Oncol, Houston, TX 77030 USA
来源:
NATURE CLINICAL PRACTICE ONCOLOGY
|
2005年
/
2卷
/
10期
关键词:
FDG;
head and neck cancer;
PET/CT;
radiation therapy;
treatment planning;
D O I:
10.1038/ncponc0322
中图分类号:
R73 [肿瘤学];
学科分类号:
100214 ;
摘要:
The evolving utilization of functional imaging, mainly 2-[F-18]fluoro-2-deoxyglucose ((18)FDG) imaging, with positron emission tomography (PET) and PET/CT, is profoundly altering head and neck tumor staging approaches, radiation treatment planning, and follow-up management. Tumor-node-metastasis staging with PET/CT has improved the characterization of patient disease versus CT, MRI, or PET alone, thereby affecting patient disease management. Therefore, the utilization of PET/CT is appropriate for head and neck cancer staging in the initial presentation and in the recurrent setting. In the setting of radiation therapy treatment planning, PET-directed tumor volume contouring is not ready for clinical practice without further technological improvements in imaging specificity/sensitivity and resolution. Patient or organ motion might interfere with the accuracy of anatomical co-alignment, and variability in defining the threshold of imaging signals on PET images can affect the contour of the biological tumor volume. The use of PET/CT for staging and detecting both primary and recurrent head and neck cancer is valuable; however, its application in radiation treatment planning should be viewed as investigational.