Comparison of wavelet transformation and adaptive filtering in restoring artefact-induced time-related measurement

被引:53
作者
Foo, Jong Yong A. [1 ]
机构
[1] Nanyang Technol Univ, Biomed Engn Res Ctr, Singapore 637553, Singapore
关键词
Pulse transit time; Heart rate; Wavelet transform; Adaptive filter; Time-related measurement;
D O I
10.1016/j.bspc.2006.01.001
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Photoplethysmography (PPG) can be used in tin-re-related measurements such as heart rate (HR) and pulse transit time (PTT) estimations in the medical fields. The accuracy of these two parameters is heavily dependent on the minimal phase variability of the PPG signals. Moreover, motion artefact is a common phenomenon that can contaminate the PPG signals. This paper compares the capabilities of two signal processing techniques: digital adaptive filtering and discrete wavelet transformation, in restoring artefact-induced PPG signals during two regulated mild movements. HR comparison was evaluated against estimates attained from an electrocardiogram (ECG) while PTT evaluation was based on a reference PPG source free of artefacts. Comparison criteria was based on documented evidences that a HR difference of < 10 beats per minute (bpm) and relative PTT changes of < 15 ms can be considered as normal. The obtained results reveal that wavelet transformation is limited in restoring corrupted PPG signals for both HR and PTT measurements. It can also be observed its inherent algorithm can induce unwarranted phase variability that can compromise clinical interpretation of these two physiologic parameters. Promising signal processing algorithms may be attractive for its improved image and/or signal restoration however. its suitability in time-related measurements warrants further investigations. (c) 2006 Elsevier Ltd. All rights reserved.
引用
收藏
页码:93 / 98
页数:6
相关论文
共 16 条
[1]   Discrete wavelets transform for signal denoising in capillary electrophoresis with electrochemiluminescence detection [J].
Cao, WD ;
Chen, XY ;
Yang, XR ;
Wang, EK .
ELECTROPHORESIS, 2003, 24 (18) :3124-3130
[2]   Motion artefact reduction of the photoplethysmographic signal in pulse transit time measurement [J].
Foo J.Y.A. ;
Wilson S.J. ;
Williams G.R. ;
Harris M. ;
Cooper D.M. .
Australasian Physics & Engineering Sciences in Medicine, 2004, 27 (4) :165-173
[3]   Variability in time delay between two models of pulse oximeters for deriving the photoplethysmographic signals [J].
Foo, JYA ;
Wilson, SJ ;
Dakin, C ;
Williams, G ;
Harris, MA ;
Cooper, D .
PHYSIOLOGICAL MEASUREMENT, 2005, 26 (04) :531-544
[4]   Pulse transit time as a derived noninvasive mean to monitor arterial distensibility changes in children [J].
Foo, JYA ;
Wilson, SJ ;
Williams, G ;
Harris, MA ;
Cooper, D .
JOURNAL OF HUMAN HYPERTENSION, 2005, 19 (09) :723-729
[5]   A new method for pulse oximetry possessing inherent insensitivity to artifact [J].
Hayes, MJ ;
Smith, PR .
IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 2001, 48 (04) :452-461
[6]   Monitoring of heart and respiratory rates in newborn infants using a new photoplethysmographic technique [J].
Johansson, A ;
Öberg, PÅ ;
Sedin, G .
JOURNAL OF CLINICAL MONITORING AND COMPUTING, 1999, 15 (7-8) :461-467
[7]   Measuring orientation of human body segments using miniature gyroscopes and accelerometers [J].
Luinge, HJ ;
Veltink, PH .
MEDICAL & BIOLOGICAL ENGINEERING & COMPUTING, 2005, 43 (02) :273-282
[8]   Monitoring of heart and respiratory rates by photoplethysmography using a digital filtering technique [J].
Nakajima, K ;
Tamura, T ;
Miike, H .
MEDICAL ENGINEERING & PHYSICS, 1996, 18 (05) :365-372
[9]   Pulse transit time improves detection of sleep respiratory events and microarousals in children [J].
Pépin, JL ;
Delavie, N ;
Pin, I ;
Deschaux, C ;
Argod, R ;
Bost, M ;
Levy, P .
CHEST, 2005, 127 (03) :722-730
[10]   Value of beat-to-beat blood pressure changes, detected by pulse transit time, in the management of the obstructive sleep apnoea/hypopnoea syndrome [J].
Pitson, DJ ;
Stradling, JR .
EUROPEAN RESPIRATORY JOURNAL, 1998, 12 (03) :685-692