Accuracy of Sentinel Lymph Node Biopsy in Breast Cancer: Pitfalls in the Application of Single Tracers

被引:9
作者
Yang, Jiqiao [1 ,2 ]
Xu, Li [1 ]
Liu, Pengcheng [1 ]
Du, Zhenggui [1 ]
Chen, Jie [1 ]
Liang, Faqing [1 ]
Long, Quanyi [1 ]
Zhang, Di [1 ,3 ]
Zeng, Helin [1 ]
Lv, Qing [1 ]
机构
[1] Sichuan Univ, West China Hosp, Dept Breast Surg, Guoxuexiang 37, Chengdu 610041, Peoples R China
[2] Sichuan Univ, West China Hosp, Clin Res Ctr Breast, Chengdu, Peoples R China
[3] Kanazawa Univ, Canc Res Inst, Kanazawa, Ishikawa, Japan
来源
CANCER MANAGEMENT AND RESEARCH | 2020年 / 12卷
基金
中国国家自然科学基金;
关键词
breast cancer; sentinel lymph node; radioisotope; blue dye; single tracer; SUPERPARAMAGNETIC IRON-OXIDE; AMERICAN-SOCIETY; BLUE-DYE; ONCOLOGY; LOCALIZATION; IDENTIFICATION; LOCATION;
D O I
10.2147/CMAR.S244806
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
Background: Radioisotopes and blue dyes are used as dual tracers in the current gold standard procedure of sentinel lymph node (SLN) biopsy (SLNB) performed for breast cancer. However, the blue dye or the radioisotope as a single tracer is also being applied in some institutes. We aimed to explore the risk factors for the miss-detection of SLNs with the radioisotope and the blue dye and to describe the distribution of SLNs missed by each tracer. Patients and Methods: Patients undergoing SLNB with radioisotope and blue dye as dual mapping agents were enrolled between August 2010 and August 2018. Radioactivity count, blue dye staining status, and size and location of each SLN were prospectively documented. Results: In total, 2382 SLNs from 1010 patients were included for statistical analyses. The sentinel node identification rate was 100% for dual tracers, 99.4% for radioisotope, and 89.1% for blue dye. SLN identification using the blue dye was more likely to fail in patients undergoing breast-conserving surgery (p < 0.001) and mastectomy with reconstruction (p = 0.005). Furthermore, miss-detection was significantly more frequent in smaller and uninvolved nodes. Among all SLNs, 8.2% were located in level II and one was in level III. Notably, single tracer of blue dye tended to fail in the detection of lymph nodes in higher levels (p < 0.001). Conclusion: This study explored the association between features and the incidence of the failure to detect SLNs using radioisotope and blue dye. The locations of the miss-detected SLNs are demonstrated to provide a reference for SLNBs conducted using blue dye or radioisotope as a single tracer.
引用
收藏
页码:3045 / 3051
页数:7
相关论文
共 33 条
  • [1] Preoperative diagnosis of the axillary arch with multidetector row computed tomography and the axillary arch in association with anatomical problems of sentinel lymph node biopsy
    Ando, Jiro
    Kitamura, Tosuke
    Kuroki, Yoshifumi
    Igarashi, Seiji
    [J]. BREAST CANCER, 2010, 17 (01) : 3 - 8
  • [2] Rural and urban disparities in the evolution of sentinel lymph node utilization in breast cancer
    Arrington, Amanda K.
    Kruper, Laura
    Vito, Courtney
    Yim, John
    Kim, Joseph
    Chen, Steven L.
    [J]. AMERICAN JOURNAL OF SURGERY, 2013, 206 (05) : 674 - 681
  • [3] Ultrasound of the axilla: where to look for the sentinel lymph node
    Britton, P.
    Moyle, P.
    Benson, J. R.
    Goud, A.
    Sinnatamby, R.
    Barter, S.
    Gaskarth, M.
    Provenzano, E.
    Wallis, M.
    [J]. CLINICAL RADIOLOGY, 2010, 65 (05) : 373 - 376
  • [4] Improved Axillary Evaluation Following Neoadjuvant Therapy for Patients With Node-Positive Breast Cancer Using Selective Evaluation of Clipped Nodes: Implementation of Targeted Axillary Dissection
    Caudle, Abigail S.
    Yang, Wei T.
    Krishnamurthy, Savitri
    Mittendorf, Elizabeth A.
    Black, Dalliah M.
    Gilcrease, Michael Z.
    Bedrosian, Isabelle
    Hobbs, Brian P.
    DeSnyder, Sarah M.
    Hwang, Rosa F.
    Adrada, Beatriz E.
    Shaitelman, Simona F.
    Chavez-MacGregor, Mariana
    Smith, Benjamin D.
    Candelaria, Rosalind P.
    Babiera, Gildy V.
    Dogan, Basak E.
    Santiago, Lumarie
    Hunt, Kelly K.
    Kuerer, Henry M.
    [J]. JOURNAL OF CLINICAL ONCOLOGY, 2016, 34 (10) : 1072 - +
  • [5] New anatomical classification of the axilla with implications for sentinel node biopsy
    Clough, K. B.
    Nasr, R.
    Nos, C.
    Vieira, M.
    Inguenault, C.
    Poulet, B.
    [J]. BRITISH JOURNAL OF SURGERY, 2010, 97 (11) : 1659 - 1665
  • [6] Complementarity of Blue Dye and Isotope in Sentinel Node Localization for Breast Cancer: Univariate and Multivariate Analysis of 966 Procedures
    Hiram S. Cody
    Jane Fey
    Tim Akhurst
    Melissa Fazzari
    Madhu Mazumdar
    Henry Yeung
    Samuel D. J. Yeh
    Patrick I. Borgen
    [J]. Annals of Surgical Oncology, 2001, 8 (1) : 13 - 19
  • [7] Value of Sentinel Lymph Node Biopsy in Breast Cancer Patients with Previous Excisional Biopsy
    Coskun, Gokhan
    Dogan, Lutfi
    Karaman, Niyazi
    Ozaslan, Cihangir
    Atalay, Can
    [J]. JOURNAL OF BREAST CANCER, 2012, 15 (01) : 87 - 90
  • [8] Abandoning sentinel lymph node biopsy in early breast cancer? A new trial in progress at the European Institute of Oncology of Milan (SOUND: Sentinel node vs Observation after axillary UltraSouND)
    Gentilini, Oreste
    Veronesi, Umberto
    [J]. BREAST, 2012, 21 (05) : 678 - 681
  • [9] Axillary Dissection vs No Axillary Dissection in Women With Invasive Breast Cancer and Sentinel Node Metastasis A Randomized Clinical Trial
    Giuliano, Armando E.
    Hunt, Kelly K.
    Ballman, Karla V.
    Beitsch, Peter D.
    Whitworth, Pat W.
    Blumencranz, Peter W.
    Leitch, A. Marilyn
    Saha, Sukamal
    McCall, Linda M.
    Morrow, Monica
    [J]. JAMA-JOURNAL OF THE AMERICAN MEDICAL ASSOCIATION, 2011, 305 (06): : 569 - 575
  • [10] Factors affecting failed localisation and false-negative rates of sentinel node biopsy in breast cancer - results of the ALMANAC validation phase
    Goyal, Amit
    Newcombe, Robert G.
    Chhabra, Alok
    Mansel, Robert E.
    [J]. BREAST CANCER RESEARCH AND TREATMENT, 2006, 99 (02) : 203 - 208