Distribution Pattern of Total Corneal Thickness in Keratoconus versus Normal Eyes Using an Optical Coherence Tomography

被引:6
作者
Hashemi, Hassan [1 ]
Heidari, Zahra [2 ,3 ]
Mohammadpour, Mehrdad [1 ,4 ]
Momeni-Moghaddam, Hamed [5 ,6 ]
Khabazkhoob, Mehdi [7 ]
机构
[1] Noor Eye Hosp, Noor Ophthalmol Res Ctr, Tehran, Iran
[2] Mazandaran Univ Med Sci, Bu Ali Sina Hosp, Dept Ophthalmol, Sari, Iran
[3] Mazandaran Univ Med Sci, Sch Allied Med Sci, Dept Rehabil Sci, Sari, Iran
[4] Univ Tehran Med Sci, Farabi Eye Hosp, Dept Ophthalmol, Tehran, Iran
[5] Zahedan Univ Med Sci, Hlth Promot Res Ctr, Zahedan, Iran
[6] Mashhad Univ Med Sci, Sch Paramed Sci, Dept Optometry, Mashhad, Iran
[7] Shahid Beheshti Univ Med Sci, Sch Nursing & Midwifery, Dept Med Surg Nursing, Tehran, Iran
关键词
Corneal thickness; Keratoconus; Spectral-domain optical coherence tomography; IN-SITU KERATOMILEUSIS; PACHYMETRY; TOPOGRAPHY; ULTRASOUND; PENTACAM; ORBSCAN;
D O I
10.4103/joco.joco_198_21
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Purpose: To evaluate the total corneal thickness distribution pattern using a high-resolution spectral-domain optical coherence tomography (HR SD-OCT) for distinguishing normal eyes from keratoconus (KCN). Methods: One hundred and forty-four patients were enrolled in three groups (55 normal, 45 mild KCN, and 44 moderate-to-severe KCN eyes) in this prospective diagnostic test study. Total corneal thickness was measured in 8 semi-meridians using HR SD-OCT (Heidelberg Engineering, Heidelberg, Germany) in 5 and 7 mm zones. The central corneal thickness (CCT), corneal focal thinning (minimum thickness [Min], min minus median and maximum [Min-Med, Min-Max]), and asymmetry indices (inferior minus superior [I-S] and supranasal minus infratemporal [SN-IT]) were calculated. One-way analysis of variance and the area under the receiver operating characteristic curve (AUC) were used for the analysis. Results: Thinner CCT, lower Min thickness, more negative Min-Max, Min-Med, and greater I-S and SN-IT were found in KCN eyes compared to the control group (P < 0.001). The inferior and IT semi-meridians were the thinnest locations in KCN cases in the 5 mm central zone (P < 0.001). CCT followed by Min-Med had the highest discriminative ability for differentiating mild KCN (AUC, sensitivity and specificity: 0.822, 87.0%, 60.37% and 0.805, 82.93%, 66.0%, respectively) and moderate-to-severe KCN (0.902, 87.82%, 73.08% and 0.892, 85.37%, and 78.85%, respectively) from normal corneas. Conclusion: The inferior and IT sectors of the cornea with the largest thickness changes in the 5 mm zone are the most common thinning sites in keratoconic corneas, and CCT and Min-Med are the most sensitive indices for the diagnosis of KCN.
引用
收藏
页码:216 / 222
页数:7
相关论文
共 31 条
[1]   Safety and Efficacy of Sequential Intracorneal Ring Segment Implantation and Cross-linking in Pediatric Keratoconus [J].
Abdelmassih, Youssef ;
El-Khoury, Sylvain ;
Dirani, Ali ;
Antonios, Rafic ;
Fadlallah, Ali ;
Cherfan, Carole G. ;
Chelala, Elias ;
Jarade, Elias F. .
AMERICAN JOURNAL OF OPHTHALMOLOGY, 2017, 178 :51-57
[2]   Corneal-thickness spatial profile and corneal-volume distribution: Tomographic indices to detect keratoconus [J].
Ambrosio, Renato, Jr. ;
Alonso, Ruiz Simonato ;
Luz, Allan ;
Coca Velarde, Luis Guillermo .
JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2006, 32 (11) :1851-1859
[3]   Keratoconus evaluation using the Orbscan Topography System [J].
Auffarth, GU ;
Wang, L ;
Völcker, HE .
JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2000, 26 (02) :222-228
[4]   Central and Peripheral Corneal Thinning in Keratoconus [J].
Brautaset, Rune L. ;
Nilsson, Maria ;
Miller, William L. ;
Leach, Norman E. ;
Tukler, Johanna H. ;
Bergmanson, Jan P. G. .
CORNEA, 2013, 32 (03) :257-261
[5]   Assessment of Corneal Epithelial Thickness in Asymmetric Keratoconic Eyes and Normal Eyes Using Fourier Domain Optical Coherence Tomography [J].
Catalan, S. ;
Cadarso, L. ;
Esteves, F. ;
Salgado-Borges, J. ;
Lopez, M. ;
Cadarso, C. .
JOURNAL OF OPHTHALMOLOGY, 2016, 2016
[6]   Pseudokeratoconus caused by rosacea [J].
Dursun, D ;
Piniella, AM ;
Pflugfelder, SC .
CORNEA, 2001, 20 (06) :668-669
[7]   Corneal Thickness in Keratoconus Comparing Optical, Ultrasound, and Optical Coherence Tomography Pachymetry [J].
Dutta, Debarun ;
Rao, Harsha L. ;
Addepalli, Uday K. ;
Vaddavalli, Pravin K. .
OPHTHALMOLOGY, 2013, 120 (03) :457-463
[8]   Global Survey of Corneal Transplantation and Eye Banking [J].
Gain, Philippe ;
Jullienne, Remy ;
He, Zhiguo ;
Aldossary, Mansour ;
Acquart, Sophie ;
Cognasse, Fabrice ;
Thuret, Gilles .
JAMA OPHTHALMOLOGY, 2016, 134 (02) :167-173
[9]   Comparison of central corneal thickness measurements using optical low-coherence reflectometry, Fourier domain optical coherence tomography, and Scheimpflug camera [J].
Gonul, Saban ;
Koktekir, Bengu Ekinci ;
Bakbak, Berker ;
Gedik, Sansal .
ARQUIVOS BRASILEIROS DE OFTALMOLOGIA, 2014, 77 (06) :345-350
[10]   Corneal thickness and elevation measurements using swept-source optical coherence tomography and slit scanning topography in normal and keratoconic eyes [J].
Jhanji, Vishal ;
Yang, Bingzhi ;
Yu, Marco ;
Ye, Cong ;
Leung, Christopher K. S. .
CLINICAL AND EXPERIMENTAL OPHTHALMOLOGY, 2013, 41 (08) :735-745