Controllable in-situ cell electroporation with cell positioning and impedance monitoring using micro electrode array

被引:43
作者
Guo, Xiaoliang [1 ]
Zhu, Rong [1 ]
机构
[1] Tsinghua Univ, Dept Precis Instrument, State Key Lab Precis Measurement Technol & Instru, Beijing 100084, Peoples R China
基金
中国国家自然科学基金;
关键词
SINGLE-CELL; GENE-TRANSFER; DELIVERY; TRANSFECTION;
D O I
10.1038/srep31392
中图分类号
O [数理科学和化学]; P [天文学、地球科学]; Q [生物科学]; N [自然科学总论];
学科分类号
07 ; 0710 ; 09 ;
摘要
This paper reports a novel microarray chip for in-situ, real-time and selective electroporation on individual cells integrated with cell positioning and impedance monitoring. An array of quadrupole-electrode units (termed positioning electrodes) and pairs of planar center electrodes located at the centers of each quadrupole-electrode unit were fabricated on the chip. The positioning electrodes are used to trap and position living cells onto the center electrodes based on negative dielectrophoresis (nDEP). The center electrodes are used for in-situ cell electroporation, and also used to measure cell impedance for monitoring cellular dynamics in real time. Controllably selective electroporation and electrical measurement on the cells in array are realized. We present an evidence of selective electroporation through use of fluorescent dyes. Subsequently we use in-situ and real-time impedance measurement to monitor the process, which demonstrates the dynamic behavior of the cell electroporation. Finally, we show the use of this device to perform successful transfection onto individual HeLa cells with vector DNA encoding a green fluorescent.
引用
收藏
页数:8
相关论文
共 26 条
[1]   Virus-based gene transfer approaches and adipose tissue biology [J].
Casteilla, Louis ;
Cousin, Beatrice ;
Planat-Benard, Valerie ;
Laharrague, Patrick ;
Carmona, Mamen ;
Penicaud, Luc .
CURRENT GENE THERAPY, 2008, 8 (02) :79-87
[2]   CHANGES IN MEMBRANE-STRUCTURE INDUCED BY ELECTROPORATION AS REVEALED BY RAPID-FREEZING ELECTRON-MICROSCOPY [J].
CHANG, DC ;
REESE, TS .
BIOPHYSICAL JOURNAL, 1990, 58 (01) :1-12
[3]   Delivery of molecules into cells using localized single cell electroporation on ITO micro-electrode based transparent chip [J].
Chen, Sheng-Chiech ;
Santra, Tuhin Subhra ;
Chang, Chia-Jung ;
Chen, Tsung-Ju ;
Wang, Pen-Cheng ;
Tseng, Fan-Gang .
BIOMEDICAL MICRODEVICES, 2012, 14 (05) :811-817
[4]   Modeling electroporation in a single cell. I. Effects of field strength and rest potential [J].
DeBruin, KA ;
Krassowska, W .
BIOPHYSICAL JOURNAL, 1999, 77 (03) :1213-1224
[5]   A microchip integrating cell array positioning with in situ single-cell impedance measurement [J].
Guo, Xiaoliang ;
Zhu, Rong ;
Zong, Xianli .
ANALYST, 2015, 140 (19) :6571-6578
[6]   A biocompatible microchip and methodology for efficiently trapping and positioning living cells into array based on negative dielectrophoresis [J].
Guo, Xiaoliang ;
Zhu, Rong .
JOURNAL OF APPLIED PHYSICS, 2015, 117 (21)
[7]   Controllably moving individual living cell in an array by modulating signal phase difference based on dielectrophoresis [J].
Guo, Xiaoliang ;
Zhu, Rong .
BIOSENSORS & BIOELECTRONICS, 2015, 68 :529-535
[8]   Nonviral Approach for Targeted Nucleic Acid Delivery [J].
Jafari, M. ;
Soltani, M. ;
Naahidi, S. ;
Karunaratne, D. N. ;
Chen, P. .
CURRENT MEDICINAL CHEMISTRY, 2012, 19 (02) :197-208
[9]   In situ electroporation of surface-bound siRNAs in microwell arrays [J].
Jain, Tilak ;
Papas, Adrian ;
Jadhav, Amol ;
McBride, Ryan ;
Saez, Enrique .
LAB ON A CHIP, 2012, 12 (05) :939-947
[10]   Highly parallel introduction of nucleic acids into mammalian cells grown in microwell arrays [J].
Jain, Tilak ;
McBride, Ryan ;
Head, Steven ;
Saez, Enrique .
LAB ON A CHIP, 2009, 9 (24) :3557-3566