Shear bond strength of bonding to enamel with different laser irradiation distances

被引:25
作者
Basaran, Guvenc [1 ]
Hamamci, Nihal [1 ]
Akkurt, Atilim [1 ]
机构
[1] Dicle Univ, Fac Dent, Dept Orthodont, TR-21280 Diyarbakir, Turkey
关键词
Laser; Er:YAG; Er; Cr:YSGG; Irradiation distance; Shear test; ER-YAG-LASER; HUMAN DENTAL ENAMEL; ORTHODONTIC BRACKETS; ERYAG LASER; IN-VITRO; SURFACE; DENTISTRY; PATTERN; TISSUES; SYSTEM;
D O I
10.1007/s10103-009-0747-3
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
The aim of this study was to investigate the shear bond strength of bonding to enamel following laser etching with the Er:YAG or Er,Cr:YSGG laser using different irradiation distances. Of 99 extracted human premolar teeth, 90 were divided equally into nine groups. In the control group (group A) the teeth were etched with 38% phosphoric acid. In the laser groups (groups B-I) the enamel surface of the teeth was laser-irradiated, groups B-E with the Er:YAG laser and groups F-I with the Er,Cr:YSGG laser at distances of 1, 2, 4 and 6 mm, respectively. The shear bond strengths were tested using a universal testing machine. The shear bond strengths associated with the Er:YAG laser at 4 and 6 mm and the Er,Cr:YSGG laser at 2, 4 and 6 mm were significantly less than the strengths obtained with the other irradiation distances (p < 0.001). The Er:YAG laser at 1 mm and the Er,Cr:YSGG laser at 1 mm etched enamel in the same manner (p > 0.05). This finding was confirmed by scanning electron microscopy examination. Irradiation distance did influence the strength of adhesion to enamel. The mean shear bond strengths and enamel surface etching obtained with the Er:YAG laser at 1 and 2 mm and the Er,Cr:YSGG laser at 1 mm were comparable to that obtained with acid etching.
引用
收藏
页码:149 / 156
页数:8
相关论文
共 34 条
[1]  
Aizawa K, 2008, J ADHES DENT, V10, P295
[2]   Calcium solubility of dental enamel following sub-ablative Er:YAG and Er:YSGG laser irradiation in vitro [J].
Apel, C ;
Meister, J ;
Schmitt, N ;
Gräber, HG ;
Gutknecht, N .
LASERS IN SURGERY AND MEDICINE, 2002, 30 (05) :337-341
[3]   ENAMEL SURFACE-ROUGHNESS ANALYSIS AFTER LASER ABLATION AND ACID-ETCHING [J].
ARCORIA, CJ ;
LIPPAS, MG ;
VITASEK, BA .
JOURNAL OF ORAL REHABILITATION, 1993, 20 (02) :213-224
[4]   Scanning electron microscopic analysis of diseased and healthy dental hard tissues after Er:YAG laser irradiation:: In vitro study [J].
Armengol, V ;
Jean, A ;
Rohanizadeh, R ;
Hamel, H .
JOURNAL OF ENDODONTICS, 1999, 25 (08) :543-546
[5]   Thermal effects of Er:YAG laser on a simulated dental pulp: a quantitative evaluation of the effects of a water spray [J].
Attrill, DC ;
Davies, RM ;
King, TA ;
Dickinson, MR ;
Blinkhorn, AS .
JOURNAL OF DENTISTRY, 2004, 32 (01) :35-40
[6]   Etching enamel for orthodontics with an erbium, chromium:yttrium-scandium-gallium-garnet laser system [J].
Basaran, Guvenc ;
Ozer, Torun ;
Berk, Nukhet ;
Hamamci, Orhan .
ANGLE ORTHODONTIST, 2007, 77 (01) :117-123
[7]   Effect of a self-etch primer/adhesive on the shear bond strength of orthodontic brackets [J].
Bishara, SE ;
VonWald, L ;
Laffoon, JF ;
Warren, JJ .
AMERICAN JOURNAL OF ORTHODONTICS AND DENTOFACIAL ORTHOPEDICS, 2001, 119 (06) :621-624
[8]  
Buonocore M.G., 1955, J DENT RES, V34, P849, DOI [DOI 10.1177/00220345550340060801, 10.1177/00220345550340060801]
[9]  
Chigira H, 1989, Dent Mater J, V8, P86
[10]   Dentistry for the 21st century? Erbium:YAG laser for teeth [J].
Cozean, C ;
Arcoria, CJ ;
Pelagalli, J ;
Powell, GL .
JOURNAL OF THE AMERICAN DENTAL ASSOCIATION, 1997, 128 (08) :1080-1087