Comparative study of air source and ground source heat pumps in 10 coldest Russian cities based on energy-exergy-economic-environmental analysis

被引:58
作者
Nikitin, Andrey [1 ]
Deymi-Dashtebayaz, Mahdi [1 ]
Muraveinikov, Sergei [1 ]
Nikitina, Veronika [1 ]
Nazeri, Reza [2 ]
Farahnak, Mehdi [3 ]
机构
[1] ITMO Univ, Fac Cryogen Engn, St Petersburg, Russia
[2] Hakim Sabzevari Univ, Dept Mech Engn, Ctr Computat Energy, Sabzevar, Iran
[3] Isfahan Univ Technol, Dept Mech Engn, Esfahan, Iran
关键词
Air source heat pump; Ground source heat pump; Coefficient of performance; Exergoeconomic analysis; Optimization; WATER-HEATER; WASTE-WATER; SYSTEM; PERFORMANCE; FEASIBILITY; REFRIGERANT; TEMPERATURE; WORKING;
D O I
10.1016/j.jclepro.2021.128979
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
As one of the environmentally friendly technologies, heat pumps have been widely utilized in residential and commercial buildings all over the world. The use of renewable energy sources and environmentally friendly refrigerants are two major challenges associated with heat pumps applications. Due to the advantages of cascade heat pumps over single-stage heat pumps and the higher energy demand met by cascade heat pumps, investigation of the effects of geographic conditions (weather and soil conditions) as well as the simultaneous use of two refrigerants for high and low temperature cycles on performance of cascade heat pumps would provide critical information for practical applications. This paper compares the performance of air source and ground source cascade heat pumps using refrigerants by low global warming potential and zero ozone depletion potential in top 10 coldest cities of Russia. The effects of variations in temperature of evaporator and cascade heat exchanger on optimal operational conditions are investigated based on energy, exergy, economic and environmental analysis using Pareto front curve. Optimization results show that there is an optimal point for evaporator temperature and cascade heat exchanger temperature where the maximum COP, maximum exergy efficiency and minimum total cost rate for ASHP and GSHP systems are obtained. It is found that at low air temperature, since the underground temperature is higher than ambient air, the efficiency of GSHP system is better than efficiency of ASHP system. The maximum COP of 2.357 and 2.44 are respectively obtained for ASHP and GSHP systems in Saint Petersburg. In addition, Yakutsk city has the maximum exergy efficiency of 40.7% and 43.2% and maximum total cost rate of 14714 $ year 1 and 13693 $ year 1 for ASHP and GSHP systems, respectively. Finally, it is concluded that Saint Petersburg is the best city to employ ASHP system while GSHP system is suggested for Khabarovsk city.
引用
收藏
页数:14
相关论文
共 44 条
[1]   Do ground source heat pumps challenge the dominant position of district heating in the Swedish heating market? [J].
Aberg, Magnus ;
Falting, Lars ;
Lingfors, David ;
Nilsson, Annica M. ;
Forssell, Anders .
JOURNAL OF CLEANER PRODUCTION, 2020, 254
[2]  
Aditya G.R., 2018, IGSHPA RES TRACK, P18
[3]  
[Anonymous], 2013, P ASME 2013 INT MECH
[4]  
[Anonymous], 2021, WORLDWIDE WEATHER FO
[5]   A study on the design and analysis of a heat pump heating system using wastewater as a heat source [J].
Baek, NC ;
Shin, UC ;
Yoon, JH .
SOLAR ENERGY, 2005, 78 (03) :427-440
[6]   Advances in heat pump systems: A review [J].
Chua, K. J. ;
Chou, S. K. ;
Yang, W. M. .
APPLIED ENERGY, 2010, 87 (12) :3611-3624
[7]   Using the potential of energy losses in gas pressure reduction stations for producing power and fresh water [J].
Deymi-Dashtebayaz, Mahdi ;
Dadpour, Daryoush ;
Khadem, Javad .
DESALINATION, 2021, 497 (497)
[8]   Investigation of the effect of using various HFC refrigerants in geothermal heat pump with residential heating applications [J].
Deymi-Dashtebayaz, Mahdi ;
Maddah, Saeed ;
Goodarzi, Marjan ;
Maddah, Omid .
JOURNAL OF THERMAL ANALYSIS AND CALORIMETRY, 2020, 141 (01) :361-372
[9]   Multi objective optimization of using the surplus low pressure steam from natural gas refinery in the thermal desalination process [J].
Deymi-Dashtebayaz, Mahdi ;
Tayyeban, Edris .
JOURNAL OF CLEANER PRODUCTION, 2019, 238
[10]   Simultaneous use of air-side and water-side economizers with the air source heat pump in a data center for cooling and heating production [J].
Deymi-Dashtebayaz, Mandi ;
Namanlo, Sajjad Valipour ;
Arabkoohsar, Ahmad .
APPLIED THERMAL ENGINEERING, 2019, 161