Feasibility study of a geothermal power plant with a double-pipe heat exchanger

被引:13
|
作者
Galoppi, G. [1 ]
Biliotti, D. [1 ]
Ferrara, G. [1 ]
Carnevale, E. A. [1 ]
Ferrari, L. [2 ]
机构
[1] Univ Florence, Dipartimento Ingn Ind, I-50139 Florence, Italy
[2] CNR, ICCOM CNR, Via Madonna del Piano 10, I-50019 Sesto Fiorentino, Italy
来源
69TH CONFERENCE OF THE ITALIAN THERMAL ENGINEERING ASSOCIATION, ATI 2014 | 2015年 / 81卷
关键词
double-pipe; medium enthalpy; combined model 1D-2D; transient analysis; radius of influence; ENERGY;
D O I
10.1016/j.egypro.2015.12.074
中图分类号
O414.1 [热力学];
学科分类号
摘要
The technologies currently in use for the power production in the geothermal field are sometimes affected by two crucial problems: the environmental impact and the drilling costs. The first issue is related to the techniques adopted to increase the heat exchange (as artificial subsoil fracturing) or to the use of aquifers which contain pollutants that are not properly disposed or confined. The drilling costs are high because two wells are generally necessary to operate properly the power plant. An interesting solution could be the adoption of a double-pipe heat exchanger that consists in two concentric pipes placed in a single well. This setup allows the operation of the plant in a closed loop configuration with no mass exchange between the subsoil and the surface. A coupled approach based on a 1D model for the pipe and a 2D axisymmetric model for the surrounding rocks was developed in this study to investigate the actual capability of a double-pipe system in different operating conditions. (C) 2015 The Authors. Published by Elsevier Ltd.
引用
收藏
页码:193 / 204
页数:12
相关论文
共 50 条
  • [1] Modified thermal calculations of a geothermal double-pipe heat exchanger with insulation immersed into geothermal deposit
    Kujawa, T
    Nowak, W
    ADVANCED COMPUTATIONAL METHODS IN HEAT TRANSFER VI, 2000, 3 : 467 - 476
  • [2] Double-Pipe Heat Exchanger with Diffuser Channels
    Lushchik, V. G.
    Makarova, M. S.
    Reshmin, A. I.
    HIGH TEMPERATURE, 2022, 60 (SUPPL 2) : S215 - S222
  • [3] Double-Pipe Heat Exchanger with Diffuser Channels
    V. G. Lushchik
    M. S. Makarova
    A. I. Reshmin
    High Temperature, 2022, 60 : S215 - S222
  • [4] Study of scale-removal methods in a double-pipe heat exchanger
    Cho, YI
    Liu, R
    McFarland, WJ
    Fusegni, L
    HEAT TRANSFER ENGINEERING, 2000, 21 (03) : 50 - 57
  • [5] The Overall Heat Transfer Characteristics of a Double-Pipe Heat Exchanger
    Dezfoli, A. R. Ansari
    Mehrabian, M. A.
    HEAT TRANSFER RESEARCH, 2009, 40 (06) : 555 - 570
  • [6] Numerical studies of a double-pipe helical heat exchanger
    Rennie, Timothy J.
    Raghavan, Vijaya G. S.
    APPLIED THERMAL ENGINEERING, 2006, 26 (11-12) : 1266 - 1273
  • [7] Tube temperature variations in a double-pipe heat exchanger
    Smith, JFD
    TRANSACTIONS OF THE AMERICAN INSTITUTE OF CHEMICAL ENGINEERS, 1935, 31 : 588 - 591
  • [8] Experimental studies of a double-pipe helical heat exchanger
    Rennie, TJ
    Raghavan, VGS
    EXPERIMENTAL THERMAL AND FLUID SCIENCE, 2005, 29 (08) : 919 - 924
  • [9] Simulation Study for Heat Transfer Performance of Spiral Flow Double-Pipe Heat Exchanger
    Wang, Yining
    Lu, Qunhui
    Zheng, Yangyan
    Yuan, Biao
    ADVANCES IN CHEMICAL ENGINEERING II, PTS 1-4, 2012, 550-553 : 3024 - +
  • [10] What dominates heat transfer performance of a double-pipe heat exchanger
    Zheng, Dan
    Hu, Zhenwei
    Tian, Liting
    Wang, Jin
    Sunden, Bengt
    OPEN PHYSICS, 2021, 19 (01): : 863 - 866