Accuracy of Dexcom G6 Continuous Glucose Monitoring in Non-Critically Ill Hospitalized Patients With Diabetes

被引:94
作者
Davis, Georgia M. [1 ]
Spanakis, Elias K. [2 ,3 ]
Migdal, Alexandra L. [1 ]
Singh, Lakshmi G. [2 ]
Albury, Bonnie [1 ]
Urrutia, Maria Agustina [1 ]
Zamudio-Coronado, K. Walkiria [1 ]
Scott, William H. [2 ]
Doerfler, Rebecca [3 ]
Lizama, Sergio [3 ]
Satyarengga, Medha [3 ]
Munir, Kashif [3 ]
Galindo, Rodolfo J. [1 ]
Vellanki, Priyathama [1 ]
Cardona, Saumeth [1 ]
Pasquel, Francisco J. [1 ]
Peng, Limin [4 ]
Umpierrez, Guillermo E. [1 ]
机构
[1] Emory Univ, Sch Med, Dept Med, Div Endocrinol Metab & Lipids, Atlanta, GA 30322 USA
[2] Baltimore Vet Affairs Med Ctr, Div Endocrinol, Baltimore, MD USA
[3] Univ Maryland, Sch Med, Div Endocrinol Diabet & Nutr, Baltimore, MD 21201 USA
[4] Emory Univ, Rollins Sch Publ Hlth, Dept Biostatist & Bioinformat, Atlanta, GA 30322 USA
基金
美国国家卫生研究院;
关键词
COVID-19; SYSTEM;
D O I
10.2337/dc20-2856
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
OBJECTIVE Advances in continuous glucose monitoring (CGM) have transformed ambulatory diabetes management. Until recently, inpatient use of CGM has remained investigational, with limited data on its accuracy in the hospital setting. RESEARCH DESIGN AND METHODS To analyze the accuracy of Dexcom G6, we compared retrospective matched-pair CGM and capillary point-of-care (POC) glucose data from three inpatient CGM studies (two interventional and one observational) in general medicine and surgery patients with diabetes treated with insulin. Analysis of accuracy metrics included mean absolute relative difference (MARD), median absolute relative difference (ARD), and proportion of CGM values within 15, 20, and 30% or 15, 20, and 30 mg/dL of POC reference values for blood glucose >100 mg/dL or <= 100 mg/dL, respectively (% 15/15, % 20/20, % 30/30). Clinical reliability was assessed with Clarke error grid (CEG) analyses. RESULTS A total of 218 patients were included (96% with type 2 diabetes) with a mean age of 60.6 +/- 12 years. The overall MARD (n = 4,067 matched glucose pairs) was 12.8%, and median ARD was 10.1% (interquartile range 4.6, 17.6]. The proportions of readings meeting % 15/15, % 20/20, and % 30/30 criteria were 68.7, 81.7, and 93.8%, respectively. CEG analysis showed 98.7% of all values in zones A and B. MARD and median ARD were higher in the case of hypoglycemia (<70 mg/dL) and severe anemia (hemoglobin <7 g/dL). CONCLUSIONS Our results indicate that CGM technology is a reliable tool for hospital use and may help improve glucose monitoring in non-critically ill hospitalized patients with diabetes.
引用
收藏
页码:1641 / 1646
页数:6
相关论文
共 17 条
  • [1] Time Lag of Glucose From Intravascular to Interstitial Compartment in Humans
    Basu, Ananda
    Dube, Simmi
    Slama, Michael
    Errazuriz, Isabel
    Amezcua, Jose Carlos
    Kudva, Yogish C.
    Peyser, Thomas
    Carter, Rickey E.
    Cobelli, Claudio
    Basu, Rita
    [J]. DIABETES, 2013, 62 (12) : 4083 - 4087
  • [2] Clinical Targets for Continuous Glucose Monitoring Data Interpretation: Recommendations From the International Consensus on Time in Range
    Battelino, Tadej
    Danne, Thomas
    Bergenstal, Richard M.
    Amiel, Stephanie A.
    Beck, Roy
    Biester, Torben
    Bosi, Emanuele
    Buckingham, Bruce A.
    Cefalu, William T.
    Close, Kelly L.
    Cobelli, Claudio
    Dassau, Eyal
    DeVries, J. Hans
    Donaghue, Kim C.
    Dovc, Klemen
    Doyle, Francis J.
    Garg, Satish
    Grunberger, George
    Heller, Simon
    Heinemann, Lutz
    Hirsch, Irl B.
    Hovorka, Roman
    Jia, Weiping
    Kordonouri, Olga
    Kovatchev, Boris
    Kowalski, Aaron
    Laffel, Lori
    Levine, Brian
    Mayorov, Alexander
    Mathieu, Chantal
    Murphy, Helen R.
    Nimri, Revital
    Norgaard, Kirsten
    Parkin, Christopher G.
    Renard, Eric
    Rodbard, David
    Saboo, Banshi
    Schatz, Desmond
    Stoner, Keaton
    Urakami, Tatsuiko
    Weinzimer, Stuart A.
    Phillip, Moshe
    [J]. DIABETES CARE, 2019, 42 (08) : 1593 - 1603
  • [3] Statistical Tools to Analyze Continuous Glucose Monitor Data
    Clarke, William
    Kovatchev, Boris
    [J]. DIABETES TECHNOLOGY & THERAPEUTICS, 2009, 11 : S45 - S54
  • [4] Remote Continuous Glucose Monitoring With a Computerized Insulin Infusion Protocol for Critically Ill Patients in a COVID-19 Medical ICU: Proof of Concept
    Davis, Georgia M.
    Faulds, Eileen
    Walker, Tara
    Vigliotti, Debbie
    Rabinovich, Marina
    Hester, Joi
    Peng, Limin
    McLean, Barbara
    Hannon, Patricia
    Poindexter, Norma
    Saunders, Petrena
    Perez-Guzman, Citlalli
    Tekwani, Seema S.
    Martin, Greg S.
    Umpierrez, Guillermo
    Agarwal, Shivani
    Dungan, Kathleen
    Pasquel, Francisco J.
    [J]. DIABETES CARE, 2021, 44 (04) : 1055 - 1058
  • [5] Diabetes Technology in the Inpatient Setting for Management of Hyperglycemia
    Davis, Georgia M.
    Galindo, Rodolfo J.
    Migdal, Alexandra L.
    Umpierrez, Guillermo E.
    [J]. ENDOCRINOLOGY AND METABOLISM CLINICS OF NORTH AMERICA, 2020, 49 (01) : 79 - +
  • [6] The Impact of COVID-19 on CGM Use in the Hospital
    Ehrhardt, Nicole
    Hirsch, Irl B.
    [J]. DIABETES CARE, 2020, 43 (11) : 2628 - 2630
  • [7] Freckmann Guido, 2019, J Diabetes Sci Technol, V13, P575, DOI 10.1177/1932296818812062
  • [8] Comparison of the FreeStyle Libre Pro Flash Continuous Glucose Monitoring (CGM) System and Point-of-Care Capillary Glucose Testing in Hospitalized Patients With Type 2 Diabetes Treated With Basal-Bolus Insulin Regimen
    Galindo, Rodolfo J.
    Migdal, Alexandra L.
    Davis, Georgia M.
    Urrutia, Maria A.
    Albury, Bonnie
    Zambrano, Cesar
    Vellanki, Priyathama
    Pasquel, Francisco J.
    Fayfman, Maya
    Peng, Limin
    Umpierrez, Guillermo E.
    [J]. DIABETES CARE, 2020, 43 (11) : 2730 - 2735
  • [9] Continuous Glucose Monitors and Automated Insulin Dosing Systems in the Hospital Consensus Guideline
    Galindo, Rodolfo J.
    Umpierrez, Guillermo E.
    Rushakoff, Robert J.
    Basu, Ananda
    Lohnes, Suzanne
    Nichols, James H.
    Spanakis, Elias K.
    Espinoza, Juan
    Palermo, Nadine E.
    Awadjie, Dessa Garnett
    Bak, Leigh
    Buckingham, Bruce
    Cook, Curtiss B.
    Freckmann, Guido
    Heinemann, Lutz
    Hovorka, Roman
    Mathioudakis, Nestoras
    Newman, Tonya
    O'Neal, David N.
    Rickert, Michaela
    Sacks, David B.
    Seley, Jane Jeffrie
    Wallia, Amisha
    Shang, Trisha
    Zhang, Jennifer Y.
    Han, Julia
    Klonoff, David C.
    [J]. JOURNAL OF DIABETES SCIENCE AND TECHNOLOGY, 2020, 14 (06): : 1035 - 1064
  • [10] Implementation of Continuous Glucose Monitoring in the Hospital: Emergent Considerations for Remote Glucose Monitoring During the COVID-19 Pandemic
    Galindo, Rodolfo J.
    Aleppo, Grazia
    Klonoff, David C.
    Spanakis, Elias K.
    Agarwal, Shivani
    Vellanki, Priya
    Olson, Darin E.
    Umpierrez, Guillermo E.
    Davis, Georgia M.
    Pasquel, Francisco J.
    [J]. JOURNAL OF DIABETES SCIENCE AND TECHNOLOGY, 2020, 14 (04): : 822 - 832