Determination of (fluoro)quinolones in environmental water using online preconcentration with column switching linked to large sample volumes and fluorescence detection

被引:18
作者
Gil Garcia, Maria Dolores [1 ]
Belmonte Gallegos, Angel [1 ]
Santiago Valverde, Rosario [1 ]
Martinez Galera, Maria [1 ]
机构
[1] Univ Almeria, Dept Hidrogeol & Quim Analit, La Canada De San Urbano 04120, Almeria, Spain
关键词
Column switching; (Fluoro)quinolones; Large sample volumes; Online SPE-LC-LC-FD; Surface water; SOLID-PHASE EXTRACTION; LIQUID-CHROMATOGRAPHY; FLUOROQUINOLONE ANTIBIOTICS; MICROEXTRACTION; PHARMACEUTICALS; SEPARATION; RESIDUES; SEWAGE; RIVER;
D O I
10.1002/jssc.201100911
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
An analytical method based on online enrichment using coupled-column liquid chromatography with fluorescence detection has been developed to determine marbofloxacin, ciprofloxacin, danofloxacin, enrofloxacin, norfloxacin, lomefloxacin, oxolinic acid, and nalidixic acid at trace levels in surface water. The sample containing the pharmaceuticals was pumped through a short C18 column in such a way that the analytes were retained on the column, whereas polar interferences, eluting at the first of the chromatogram, were discarded to waste. Then, the analytes were transferred by the chromatographic mobile phase to a second C18 analytical column, where they were separated following a conventional chromatography. The optimized approach allowed to preconcentrate 15 mL of sample volume adjusted at acid pH with phosphoric acid and modified with 5% of methanol, at a flow rate of 1.5 mL/min in 10 min. R2 values were between 0.994 and 0.998, detection and quantitation limits ranged between 0.001 and 0.080 and between 0.002 and 0.100 mu g/L, respectively, and the interday precision was below 9.8%. Recoveries in three different surface water samples, spiked at concentration levels between 0.002 and 0.500 mu g/L (n = 3 for each spiking level), ranged from 82.1 to 125.8% with the relative standard deviation lower than 12%.
引用
收藏
页码:823 / 831
页数:9
相关论文
共 35 条
[1]  
Aiken G. R., HUMIC SUBSTANCES SOI
[2]   Determination of multi-class pharmaceuticals in wastewater by liquid chromatography-tandem mass spectrometry (LC-MS-MS) [J].
Babic, Sandra ;
Pavlovic, Dragana Mutavdzic ;
Aperger, Danijela ;
Perisa, Martina ;
Zrncic, Mirta ;
Horvat, Alka J. M. ;
Kastelan-Macan, Marija .
ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2010, 398 (03) :1185-1194
[3]  
BERTOVEX PM, 1994, DEFINITION PROCEDURE
[4]  
Brain R. A., 2009, ACS SYM SER, P169
[5]   Determination of fluoroquinolone antibiotics in environmental water samples based on magnetic molecularly imprinted polymer extraction followed by liquid chromatography-tandem mass spectrometry [J].
Chen, Ligang ;
Zhang, Xiaopan ;
Xu, Yang ;
Du, Xiaobo ;
Sun, Xin ;
Sun, Lei ;
Wang, Hui ;
Zhao, Qi ;
Yu, Aimin ;
Zhang, Hanqi ;
Ding, Lan .
ANALYTICA CHIMICA ACTA, 2010, 662 (01) :31-38
[6]  
Elmashni D, 2004, 330 THERM SCI
[7]  
*EURACHEM, 1993, 1WELAC EURACHEM
[8]   Improved liquid chromatographic determination of nine currently used (fluoro)quinolones with fluorescence and mass spectrometric detection for environmental samples [J].
Ferdig, M ;
Kaleta, A ;
Buchberger, W .
JOURNAL OF SEPARATION SCIENCE, 2005, 28 (13) :1448-1456
[9]   Improved capillary electrophoretic separation of nine (fluoro)quinolones with fluorescence detection for biological and environmental samples [J].
Ferdig, M ;
Kaleta, A ;
Vo, TDT ;
Buchberger, W .
JOURNAL OF CHROMATOGRAPHY A, 2004, 1047 (02) :305-311
[10]   Environmental risk assessment of antibiotics:: comparison of mecillinam, trimethoprim and ciprofloxacin [J].
Halling-Sorensen, B ;
Lützhoft, HCH ;
Andersen, HR ;
Ingerslev, F .
JOURNAL OF ANTIMICROBIAL CHEMOTHERAPY, 2000, 46 :53-58