Temporary Hearing Threshold Shift in Healthy Volunteers with Hearing Protection Caused by Acoustic Noise Exposure during 3-T Multisequence MR Neuroimaging

被引:27
作者
Jin, Chao [1 ]
Li, Huan [1 ]
Li, Xianjun [1 ,2 ]
Wang, Miaomiao [1 ]
Liu, Congcong [1 ]
Guo, Jianxin [1 ]
Yang, Jian [1 ,2 ]
机构
[1] Xi An Jiao Tong Univ, Affiliated Hosp 1, Dept Diagnost Radiol, 277 West Yanta Rd, Xian 710061, Shaanxi, Peoples R China
[2] Xi An Jiao Tong Univ, Sch Life Sci & Technol, Dept Biomed Engn, Xian, Shaanxi, Peoples R China
基金
中国国家自然科学基金;
关键词
SEQUENCE;
D O I
10.1148/radiol.2017161622
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: To determine whether a single 51-minute exposure to acoustic noise during 3-T multisequence magnetic resonance (MR) neuroimaging could affect the hearing threshold of healthy adults with earplugs and sponge mats as hearing protection. Materials and Methods: With earplugs and motion-refraining sponge mats as hearing protection, 26 healthy young adults underwent 3-T MR neuroimaging imaging that included T1-weighted three-dimensional gradient-echo sequence, T2-weighted fast spin-echo sequence, diffusion-tensor imaging, diffusion-kurtosis imaging, T2*-weighted three-dimensional multiecho gradient-echo sequence, and blood oxygen level-dependent imaging. Automated auditory brainstem response (ABR) was used to measure the hearing thresholds within 24 hours before, within 20 minutes after, and 25 days after the MR examination. One-way repeated-measure analysis of variance with Bonferroni adjustment was used to compare automated ABR results among the three tests and partial eta(2) (eta(2)(p)) was reported as a measure of effect size. Results: Automated ABR results showed significantly increased mean threshold shift of 5.0 dB +/- 8.1 (standard deviation) (left ear: 4.8 dB +/- 9.2 [95% confidence interval: 1.09, 8.53], eta(2)(p) = 0.221, P=.013; right ear: 5.2 dB +/- 6.9 [95% confidence interval: 2.36, 8.02], eta(2)(p) = 0.364, P=.001) immediately after the MR examination compared with the baseline study. This shift is below the temporary threshold shift of 40-50 dB that is associated with cochlea nerve changes. Automated ABR obtained at day 25 after MR imaging showed no significant differences from baseline (left ear: 22.3 dB +/- 8.6 [95% confidence interval: 25.79, 1.78], eta(2)(p) = 0.069, P=.185; right ear: 0.4 dB +/- 7.3 [95% confidence interval: 23.35, 2.58], eta(2)(p) = 0.003, P=.791). Conclusion: A 3-T MR neuroimaging examination with the acoustic noise at equivalent sound pressure level of 103.5-111.3 dBA lasting 51 minutes can cause temporary hearing threshold shift in healthy volunteers with hearing protection.
引用
收藏
页码:602 / 608
页数:7
相关论文
共 36 条
[31]  
Sharabi Y, 2002, ISR MED ASSOC J, V4, P1118
[32]   Determination of gradient magnetic field-induced acoustic noise associated with the use of echo planar and three-dimensional, fast spin echo techniques [J].
Shellock, FG ;
Ziarati, M ;
Atkinson, D ;
Chen, DY .
JMRI-JOURNAL OF MAGNETIC RESONANCE IMAGING, 1998, 8 (05) :1154-1157
[33]   MEASUREMENT OF ACOUSTIC NOISE DURING MR-IMAGING - EVALUATION OF 6 WORST-CASE PULSE SEQUENCES [J].
SHELLOCK, FG ;
MORISOLI, SM ;
ZIARATI, M .
RADIOLOGY, 1994, 191 (01) :91-93
[34]   Estimation of the pure-tone audiogram by the auditory brainstem response: A review [J].
Stapells, DR ;
Oates, P .
AUDIOLOGY AND NEURO-OTOLOGY, 1997, 2 (05) :257-280
[35]  
UK Department of Health. Medicines and Healthcare products Regulatory Agency (MHRA), 200703 MHRA DB UK DE
[36]   Effects of Repeated "Benign" Noise Exposures in Young CBA Mice: Shedding Light on Age-related Hearing Loss [J].
Wang, Yong ;
Ren, Chongyu .
JARO-JOURNAL OF THE ASSOCIATION FOR RESEARCH IN OTOLARYNGOLOGY, 2012, 13 (04) :505-515