Optimization and evaluation of multi-bed adsorbent tube method in collection of volatile organic compounds

被引:23
作者
Ho, Steven Sai Hang [1 ,2 ,3 ]
Wang, Liqin [1 ,2 ]
Chow, Judith C. [2 ,3 ]
Watson, John G. [2 ,3 ]
Xue, Yonggang [1 ,2 ]
Huang, Yu [1 ,2 ]
Qu, Linli [4 ]
Li, Bowei [5 ,6 ]
Dai, Wenting [1 ,2 ,7 ]
Li, Lijuan [1 ,2 ,7 ]
Cao, Junji [1 ,2 ]
机构
[1] Chinese Acad Sci, Inst Earth Environm, KLACP, Xian 710061, Shaanxi, Peoples R China
[2] Chinese Acad Sci, Inst Earth Environm, SKLLQG, Xian 710061, Shaanxi, Peoples R China
[3] Desert Res Inst, Div Atmospher Sci, Reno, NV 89512 USA
[4] Hong Kong Premium Serv & Res Co, Kowloon, Hong Kong, Peoples R China
[5] Xi An Jiao Tong Univ, Sch Human Settlements & Civil Engn, Dept Environm Sci & Technol, Xian 710049, Shaanxi, Peoples R China
[6] Acad Ecol Industrializat Wisedom Environm, Langfang 065000, Peoples R China
[7] Univ Chinese Acad Sci, Beijing, Peoples R China
基金
美国国家科学基金会;
关键词
VOCs; Method optimization; Thermal desorption; Adsorbent tube; Ozone precursor; POLYFLUORINATED ALKYL SUBSTANCES; PHOTOCHEMICAL OZONE FORMATION; SOURCE APPORTIONMENT; SAMPLING METHODS; CHROMATOGRAPHY/MASS SPECTROMETRY; AMBIENT AIR; HONG-KONG; TENAX-TA; VOCS; EMISSIONS;
D O I
10.1016/j.atmosres.2017.11.026
中图分类号
P4 [大气科学(气象学)];
学科分类号
0706 ; 070601 ;
摘要
The feasibility of using adsorbent tubes to collect volatile organic compounds (VOCs) has been demonstrated since the 1990's and standardized as Compendium Method TO-17 by the U.S. Environmental Protection Agency (U.S EPA). This paper investigates sampling and analytical variables on concentrations of 57 ozone (O-3) precursors (C-2-C-12 aliphatic and aromatic VOCs) specified for the Photochemical Assessment Monitoring Station (PAMS). Laboratory and field tests examined multi-bed adsorbent tubes containing a sorbate combination of Tenax TA, Carbograph 1 TD, and Carboxen 1003. Analyte stabilities were influenced by both collection tube temperature and ambient O-3 concentrations. Analytes degraded during storage, while blank levels were elevated by passive adsorption. Adsorbent tube storage under cold temperatures (- 10 degrees C) in a preservation container filled with solid silica gel and anhydrous calcium sulfate (CaSO4) ensured sample integrity. A high efficiency (> 99%) O-3 scrubber (i.e., copper coil tube filled with saturated potassium iodide [KM removed O-3 (i.e., < 200 ppbv) from the air stream with a sampling capacity of 30 h. Water vapor scrubbers interfered with VOC measurements. The optimal thermal desorption-gas chromatography/mass spectrometry (TD-GC/MS) desorption time of 8 min was found at 330 degrees C. Good linearity (R-2 > 0.995) was achieved for individual analyte calibrations (with the exception of acetylene) for mixing ratios of 0.08-1.96 ppbv. The method detection limits (MDLs) were below 0.055 ppbv for a 3 L sample volume. Replicate analyses showed relative standard deviations (RSDs) of < 10%, with the majority of the analytes within < 5%.
引用
收藏
页码:187 / 195
页数:9
相关论文
共 41 条
[1]  
Agilent Technologies, 2013, THERM DES TECHN SUPP
[2]  
Agilent Technologies, 2011, MAINT YOUR GC MS SYS
[3]  
Boudjaoui S., DEV OPTIMIZATION SIL, P263
[4]   Evaluation of the stability of a mixture of volatile organic compounds on sorbents for the determination of emissions from indoor materials and products using thermal desorption/gas chromatography/mass spectrometry [J].
Brown, Veronica M. ;
Crump, Derrick R. ;
Plant, Neil T. ;
Pengelly, Ian .
JOURNAL OF CHROMATOGRAPHY A, 2014, 1350 :1-9
[5]   Characteristics and source apportionment of VOCs measured in Shanghai, China [J].
Cai, Changjie ;
Geng, Fuhai ;
Tie, Xuexi ;
Yu, Qiong ;
An, Junlin .
ATMOSPHERIC ENVIRONMENT, 2010, 44 (38) :5005-5014
[6]   Emission of styrene from polystyrene foam and of cyclopentane from polyurethane foam - measurements and modelling [J].
Choczynski, Maciej ;
Krajewska, Barbara ;
Stegowski, Zdzislaw ;
Necki, Jaroslaw .
POLIMERY, 2011, 56 (06) :461-470
[7]  
Coutant R. W., 1993, 68DO0007 EPA
[8]   C1 to C9 volatile organic compound measurements in urban air [J].
Fernández-Villarrenaga, V ;
López-Mahía, P ;
Muniategui-Lorenzo, S ;
Prada-Rodríguez, D ;
Fernández-Fernández, E ;
Tomàs, X .
SCIENCE OF THE TOTAL ENVIRONMENT, 2004, 334 :167-176
[9]   Comparative study of the adsorption performance of an active multi-sorbent bed tube (Carbotrap, Carbopack X, Carboxen 569) and a Radiello® diffusive sampler for the analysis of VOCs [J].
Gallego, E. ;
Roca, F. J. ;
Perales, J. F. ;
Guardino, X. .
TALANTA, 2011, 85 (01) :662-672
[10]   Dry purge for the removal of water from the solid sorbents used to sample volatile organic compounds from the atmospheric air [J].
Gawlowski, J ;
Gierczak, T ;
Pietruszyñska, Z ;
Gawrys, M ;
Niedzielski, J .
ANALYST, 2000, 125 (11) :2112-2117