Primary stability in total hip replacement: A biomechanical investigation

被引:4
作者
Schmitz, Paul [1 ]
Gueorguiev, Boyko [2 ]
Zderic, Ivan [2 ]
Pfeifer, Christian [1 ]
Nerlich, Michael [1 ]
Grechenig, Stephan [1 ]
机构
[1] Univ Regensburg, Clin Trauma Surg, Franz Josef Strauss Allee 11, D-93053 Regensburg, Germany
[2] AO Res Inst Davos, Davos, Switzerland
关键词
locking screw hip stem; primary stability; screw fixation; total hip replacement; FEMORAL STEMS; FOLLOW-UP; BONE; ARTHROPLASTY; PRESERVATION; IMPLANTS; LOCKING; SCREWS;
D O I
10.1097/MD.0000000000008278
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background:In total hip replacement (THR), it is essential to achieve a primary stability to guarantee good long-term results. A novel locking screw hip (LSH)-stem, anchored to the medial cortex of the proximal femur by 5 monocortical locking screws, was developed to overcome the shortcomings of uncemented press-fit and cemented straight stems while simultaneously achieving primary stability. The aim of this study was to investigate the biomechanical competence of the LSH-stem in comparison to an uncemented press-fit stem.Methods:Six pairs of embalmed human cadaveric femora from donors aged 68 to 84 years were assigned to 2 study groups (n=6) with equal number of right and left bones. The specimens in each group and pair were implanted with either an uncemented press-fit stem or an LSH-stem and tested biomechanically under progressively increasing cyclic axial loading until catastrophic failure. Axial construct stiffness, failure load, and cycles to failure were detected and statistically evaluated at a level of significance P=.05.Results:Although the axial stiffness was comparable for both prosthesis types, the uncemented press-fit stem showed a significant lower stability in terms of failure load and cycles to failure in comparison to the LSH-stem, P=.04.Conclusion:Converting our results to percentage of bodyweight (BW) in an assumed adult patient of 80kg shows that the LSH-stem achieves a primary stability allowing to carry average loads of up to 507% BW, whereas the uncemented press-fit stem carried average loads of up to 404% BW. We conclude that both stems achieve a primary stability strong enough to carry hip joint loads experienced in the immediate rehabilitation period after THR.
引用
收藏
页数:5
相关论文
共 22 条
  • [11] Gueorguiev B, 2008, GALVANOTECHNIK, V12, P3070
  • [12] Angular Stability Potentially Permits Fewer Locking Screws Compared With Conventional Locking in Intramedullary Nailed Distal Tibia Fractures: A Biomechanical Study
    Gueorguiev, Boyko
    Ockert, Ben
    Schwieger, Karsten
    Waehnert, Dirk
    Lawson-Smith, Matthew
    Windolf, Markus
    Stoffel, Karl
    [J]. JOURNAL OF ORTHOPAEDIC TRAUMA, 2011, 25 (06) : 340 - 346
  • [13] KIM YH, 1993, CLIN ORTHOP RELAT R, P146
  • [14] New cementless fixation in hip arthroplasty: a radiostereometric analysis
    Matejcic, Aljosa
    Vidovic, Dinko
    Nebergall, Audrey
    Greene, Meridith
    Bresina, Stephen
    Tepic, Slobodan
    Malchau, Henrik
    Hodge, William A.
    [J]. HIP INTERNATIONAL, 2015, 25 (05) : 477 - 483
  • [15] Cemented Muller straight stem total hip replacement: 18 year survival, clinical and radiological outcomes
    Nikolaou, Vasileios S.
    Korres, Demetrios
    Lallos, Stergios
    Mavrogenis, Andreas
    Lazarettos, Ioannis
    Sourlas, Ioannis
    Efstathopoulos, Nicolas
    [J]. WORLD JOURNAL OF ORTHOPEDICS, 2013, 4 (04): : 303 - 308
  • [16] PILLIAR RM, 1986, CLIN ORTHOP RELAT R, P108
  • [17] Robinson R P, 1994, J Arthroplasty, V9, P177, DOI 10.1016/0883-5403(94)90067-1
  • [18] Spotorno L, 1993, Acta Orthop Belg, V59 Suppl 1, P144
  • [19] Effects of three different preservation methods on the mechanical properties of human and bovine cortical bone
    Stefan, Unger
    Michael, Blauth
    Werner, Schmoelz
    [J]. BONE, 2010, 47 (06) : 1048 - 1053
  • [20] A 10-YEAR FOLLOW-UP OF 100 CONSECUTIVE MULLER CURVED-STEM TOTAL HIP-REPLACEMENT ARTHROPLASTIES
    SUTHERLAND, CJ
    WILDE, AH
    BORDEN, LS
    MARKS, KE
    [J]. JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 1982, 64 (07) : 970 - 982