Primary stability in total hip replacement: A biomechanical investigation

被引:4
作者
Schmitz, Paul [1 ]
Gueorguiev, Boyko [2 ]
Zderic, Ivan [2 ]
Pfeifer, Christian [1 ]
Nerlich, Michael [1 ]
Grechenig, Stephan [1 ]
机构
[1] Univ Regensburg, Clin Trauma Surg, Franz Josef Strauss Allee 11, D-93053 Regensburg, Germany
[2] AO Res Inst Davos, Davos, Switzerland
关键词
locking screw hip stem; primary stability; screw fixation; total hip replacement; FEMORAL STEMS; FOLLOW-UP; BONE; ARTHROPLASTY; PRESERVATION; IMPLANTS; LOCKING; SCREWS;
D O I
10.1097/MD.0000000000008278
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background:In total hip replacement (THR), it is essential to achieve a primary stability to guarantee good long-term results. A novel locking screw hip (LSH)-stem, anchored to the medial cortex of the proximal femur by 5 monocortical locking screws, was developed to overcome the shortcomings of uncemented press-fit and cemented straight stems while simultaneously achieving primary stability. The aim of this study was to investigate the biomechanical competence of the LSH-stem in comparison to an uncemented press-fit stem.Methods:Six pairs of embalmed human cadaveric femora from donors aged 68 to 84 years were assigned to 2 study groups (n=6) with equal number of right and left bones. The specimens in each group and pair were implanted with either an uncemented press-fit stem or an LSH-stem and tested biomechanically under progressively increasing cyclic axial loading until catastrophic failure. Axial construct stiffness, failure load, and cycles to failure were detected and statistically evaluated at a level of significance P=.05.Results:Although the axial stiffness was comparable for both prosthesis types, the uncemented press-fit stem showed a significant lower stability in terms of failure load and cycles to failure in comparison to the LSH-stem, P=.04.Conclusion:Converting our results to percentage of bodyweight (BW) in an assumed adult patient of 80kg shows that the LSH-stem achieves a primary stability allowing to carry average loads of up to 507% BW, whereas the uncemented press-fit stem carried average loads of up to 404% BW. We conclude that both stems achieve a primary stability strong enough to carry hip joint loads experienced in the immediate rehabilitation period after THR.
引用
收藏
页数:5
相关论文
共 22 条
  • [1] HIP-JOINT LOADING DURING WALKING AND RUNNING, MEASURED IN 2 PATIENTS
    BERGMANN, G
    GRAICHEN, F
    ROHLMANN, A
    [J]. JOURNAL OF BIOMECHANICS, 1993, 26 (08) : 969 - 990
  • [2] Hip contact forces and gait patterns from routine activities
    Bergmann, G
    Deuretzbacher, G
    Heller, M
    Graichen, F
    Rohlmann, A
    Strauss, J
    Duda, GN
    [J]. JOURNAL OF BIOMECHANICS, 2001, 34 (07) : 859 - 871
  • [3] CLS MULTICENTER STUDY - REVIEW AFTER 8 YEARS
    BLASIUS, K
    COTTA, H
    SCHNEIDER, U
    THOMSEN, M
    [J]. ZEITSCHRIFT FUR ORTHOPADIE UND IHRE GRENZGEBIETE, 1993, 131 (06): : 547 - 552
  • [4] Three-dimensional primary stability of cementless femoral stems
    Buhler, DW
    Berlemann, U
    Lippuner, K
    Jaeger, P
    Nolte, LP
    [J]. CLINICAL BIOMECHANICS, 1997, 12 (02) : 75 - 86
  • [5] TOTAL HIP-REPLACEMENT IN PATIENTS YOUNGER THAN 30 YEARS OLD - A 5-YEAR FOLLOW-UP-STUDY
    CHANDLER, HP
    REINECK, FT
    WIXSON, RL
    MCCARTHY, JC
    [J]. JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 1981, 63 (09) : 1426 - 1434
  • [6] Initial stability of fully and partially cemented femoral stems
    Claes, L
    Fiedler, S
    Ohnmacht, M
    Duda, GN
    [J]. CLINICAL BIOMECHANICS, 2000, 15 (10) : 750 - 755
  • [7] Force transfer between the plate and the bone: relative importance of the bending stiffness of the screws and the friction between plate and bone
    Cordey, J
    Borgeaud, M
    Perren, SM
    [J]. INJURY-INTERNATIONAL JOURNAL OF THE CARE OF THE INJURED, 2000, 31 : 21 - 28
  • [8] A QUANTITATIVE-EVALUATION OF PERIPROSTHETIC BONE-REMODELING AFTER CEMENTLESS TOTAL HIP-ARTHROPLASTY
    ENGH, CA
    MCGOVERN, TF
    BOBYN, JD
    HARRIS, WH
    [J]. JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 1992, 74A (07) : 1009 - 1020
  • [9] SINTERED FIBER METAL COMPOSITES AS A BASIS FOR ATTACHMENT OF IMPLANTS TO BONE
    GALANTE, J
    ROSTOKER, W
    LUECK, R
    RAY, RD
    [J]. JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 1971, A 53 (01) : 101 - &
  • [10] A novel locking screw hip stem to achieve immediate stability in total hip arthroplasty: A biomechanical study
    Grechenig, Stephan
    Gueorguiev, Boyko
    Berner, Arne
    Heiss, Peter
    Mueller, Michael
    Nerlich, Michael
    Schmitz, Paul
    [J]. INJURY-INTERNATIONAL JOURNAL OF THE CARE OF THE INJURED, 2015, 46 : S83 - S87