OCCUPATIONAL RADIATION DOSE TO NUCLEAR MEDICINE STAFF DUE TO TC99M, F18-FDG PET AND THERAPEUTIC I-131 BASED EXAMINATIONS

被引:13
作者
Fathy, Mohamed [1 ,2 ]
Khalil, Magdy M. [3 ]
Elshemey, Wael M. [2 ]
Mohamed, Haitham S. [2 ]
机构
[1] Cairo Univ, Fac Med, Kasr Al Ainy Ctr Radiat Oncol & Nucl Med, Dept Nucl Med, Giza, Egypt
[2] Cairo Univ, Fac Sci, Dept Biophys, Giza, Egypt
[3] Helwan Univ, Fac Sci, Dept Phys, Cairo, Egypt
关键词
CORONARY-ARTERY-DISEASE; EXPOSURE; SCAN;
D O I
10.1093/rpd/ncz046
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
The aim was to track the exposure to radiation workers in six nuclear medicine examinations. A number of 180 patients were recruited and external exposure was measured. Patients had undergone cardiac stress and rest, bone scan, I-131 therapy, Gallium-67 and FDG PET/CT imaging. The average dose received due to cardiac stress and rest were 20.4 +/- 5.0 and 16.0 +/- 3.8 mu Sv per patient, respectively, whereas for bone scan, Ga-67, FDG and I-131 therapy, the average dose was 6.1 +/- 2.5, 6.0 +/- 1.4, 11.1 +/- 2.2 and 4.1 +/- 2.6 mu Sv per patient. The patient-to-staff dose coefficients were on average 0.051 +/- 0.009, 0.042 +/- 0.010, 0.034 +/- 0.016, 0.039 +/- 0.021, 0.052 +/- 0.012, 0.094 +/- 0.021 mu Sv m(2)/MBq h for stress, rest, bone, I-131, Ga-67 and FDG reported post-administration, respectively. Patient injection and setup for imaging represent a high percentage of the total dose received by staff. The information revealed is able to revise local measures, safety standards, and could help further in dose optimization and minimal exposure to occupationally exposed worker in nuclear medicine laboratories.
引用
收藏
页码:443 / 451
页数:9
相关论文
共 20 条
  • [1] Abuelfath M, 2014, J NUCL MED, V55, P1943
  • [2] Ahmed T, 2014, EANM M
  • [3] Alanezi E, 2014, J NUCL MED S1, V55, P2077
  • [4] EFFECTIVE RADIATION DOSE TO STAFF MEMBERS DUE TO MYOCARDIAL PERFUSION SPECT IMAGING: TRACKING THE EXPOSURE FROM PREPARATION TO PATIENT RELEASE
    Alramlawy, Shaban
    Khalil, Magdy Mohamed
    [J]. RADIATION PROTECTION DOSIMETRY, 2018, 182 (03) : 345 - 351
  • [5] [Anonymous], INSP OP MAN
  • [6] BUELL U, 1981, J NUCL MED, V22, P95
  • [7] OCCUPATIONAL EXPOSURE FROM F-18-FDG PET/CT: IMPLEMENTATION TO ROUTINE CLINICAL PRACTICE
    Costa, P. Fragoso
    Reinhardt, M.
    Poppe, B.
    [J]. RADIATION PROTECTION DOSIMETRY, 2018, 179 (03) : 291 - 298
  • [8] Guillet B, 2005, J NUCL MED TECHNOL, V33, P175
  • [9] Underperformance of Gallium-67 Scan is Greater in Relapse Than in Initial Staging, Compared With FDG PET
    Huang, Yu-Yi
    You, Dong-Ling
    Liu, Mei-Ching
    Tan, Tran-Der
    Lee, Pei-Ing
    Lee, Ming-Yuan
    [J]. CLINICAL NUCLEAR MEDICINE, 2011, 36 (10) : 867 - 871
  • [10] Diagnostic Performance of Noninvasive Myocardial Perfusion Imaging Using Single-Photon Emission Computed Tomography, Cardiac Magnetic Resonance, and Positron Emission Tomography Imaging for the Detection of Obstructive Coronary Artery Disease A Meta-Analysis
    Jaarsma, Caroline
    Leiner, Tim
    Bekkers, Sebastiaan C.
    Crijns, Harry J.
    Wildberger, Joachim E.
    Nagel, Eike
    Nelemans, Patricia J.
    Schalla, Simon
    [J]. JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2012, 59 (19) : 1719 - 1728