Diagnostic accuracy of computed tomography angiography for the detection of coronary artery disease in patients referred for transcatheter aortic valve implantation

被引:58
|
作者
Opolski, Maksymilian P. [1 ]
Kim, Won-Keun [1 ]
Liebetrau, Christoph [1 ]
Walther, Claudia [1 ]
Blumenstein, Johannes [1 ]
Gaede, Luise [1 ]
Kempfert, Joerg [2 ]
Van Linden, Arnaud [2 ]
Walther, Thomas [2 ]
Hamm, Christian W. [1 ]
Moellmann, Helge [1 ]
机构
[1] Kerckhoff Heart Ctr, Dept Cardiol, D-61231 Bad Nauheim, Germany
[2] Kerckhoff Heart Ctr, Dept Cardiac Surg, D-61231 Bad Nauheim, Germany
关键词
Computed tomography; Angiography; Coronary artery disease; Transcatheter aortic valve implantation; CT ANGIOGRAPHY; HEART-RATE; SURGERY; REPLACEMENT; STENOSIS;
D O I
10.1007/s00392-014-0806-z
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
We aimed to investigate the diagnostic accuracy of a standardized computed tomography angiography (CTA) for the identification of significant coronary artery disease (CAD) in patients evaluated for transcatheter aortic valve implantation (TAVI). The diagnostic performance of CTA for the detection of CAD in patients with aortic stenosis referred for TAVI has thus far not been validated. A consecutive series of 475 patients (194 male, mean age: 82 +/- A 6 years) with CTA data sets obtained during the routine diagnostic work-up before TAVI were included. A total of 6,603 coronary segments in 1,899 coronary arteries a parts per thousand yen1.5 mm in diameter and 271 grafts were evaluated for the presence of significant CAD defined as a parts per thousand yen50 % luminal narrowing. Results were compared with invasive coronary angiography as the standard of reference. Prevalence of significant CAD was 57 % (270/475), and 5,925 coronary segments (90 %) and 257 bypass grafts (95 %) were evaluable by CTA. In the per-patient analysis, sensitivity (Se), specificity, and positive and negative predictive values (NPV) were 98, 37, 67 and 94 %, respectively. CTA showed satisfactory ability to exclude significant CAD in the following subgroups: (1) patients (221/475) without prior known CAD (Se: 97 %, NPV: 97 %), (2) patients (13/475) without prior known CAD and absent coronary calcification (NPV: 100 %) and (3) bypass grafts (Se: 97 %, NPV: 99 %). Comprehensive evaluation of a pre-TAVI CTA could prove to be a useful rule-out test for significant CAD in selected subgroups of patients.
引用
收藏
页码:471 / 480
页数:10
相关论文
共 50 条
  • [41] Coronary Artery Disease Assessed by Computed Tomography-Based Leaman Score in Patients With Low-Risk Transcatheter Aortic Valve Implantation
    Ozaki, Yuichi
    Garcia-Garcia, Hector M.
    Rogers, Toby
    Torguson, Rebecca
    Craig, Paige E.
    Hideo-Kajita, Alexandre
    Gordon, Paul
    Ehsan, Afshin
    Parikh, Puja
    Bilfinger, Thomas
    Butzel, David
    Buchanan, Scott
    Levitt, Robert
    Hahn, Chiwon
    Buchbinder, Maurice
    Hanna, Nicholas
    Garrett, Robert
    Wilson, Sean R.
    Goncalves, John A.
    Ali, Syed
    Asch, Federico M.
    Weissman, Gaby
    Shults, Christian
    Ben-Dor, Itsik
    Satler, Lowell F.
    Waksman, Ron
    AMERICAN JOURNAL OF CARDIOLOGY, 2020, 125 (08) : 1216 - 1221
  • [42] Diagnostic accuracy of coronary angiography using 64-slice computed tomography in coronary artery disease
    Yang, Fu-Bin
    Guo, Wan-Liang
    Sheng, Mao
    Sun, Ling
    Ding, Yue-Yue
    Xu, Qiu-Qin
    Xu, Ming-Guo
    Lv, Hai-Tao
    SAUDI MEDICAL JOURNAL, 2015, 36 (10) : 1156 - 1162
  • [43] Coronary artery cannulation after transcatheter aortic valve implantation
    Valvo, Roberto
    Costa, Giuliano
    Tamburino, Corrado
    Barbanti, Marco
    EUROINTERVENTION, 2021, 17 (10) : 835 - 847
  • [44] Computed tomography characteristics of the aortic valve and the geometry of SAPIEN 3 transcatheter heart valve in patients with bicuspid aortic valve disease
    Kawamori, Hiroyuki
    Yoon, Sung-Han
    Chakravarty, Tarun
    Maeno, Yoshio
    Kashif, Mohammad
    Israr, Sharjeel
    Abramowitz, Yigal
    Mangat, Geeteshwar
    Miyasaka, Masaki
    Rami, Tanya
    Kazuno, Yoshio
    Takahashi, Nobuyuki
    Jilaihawi, Hasan
    Nakamura, Mamoo
    Cheng, Wen
    Friedman, John
    Berman, Daniel
    Sharma, Rahul
    Makkar, Raj R.
    EUROPEAN HEART JOURNAL-CARDIOVASCULAR IMAGING, 2018, 19 (12) : 1408 - 1418
  • [45] Impact of previous coronary artery revascularization on outcomes in patients undergoing transcatheter aortic valve implantation
    Wilimski, Radoslaw
    Huczek, Zenon
    Krauz, Kamil
    Rymuza, Bartosz
    Mazurek, Maciej
    Scislo, Piotr
    Zbronski, Karol
    Grodecki, Kajetan
    Kochman, Janusz
    Kusmierczyk, Mariusz
    POSTEPY W KARDIOLOGII INTERWENCYJNEJ, 2023, 19 (03): : 243 - 250
  • [46] Preprocedural assessment of coronary artery disease in patients undergoing transcatheter aortic valve implantation: Rationale and design of the EASE-IT CT registry
    Mascherbauer, Julia
    Rudolph, Tanja
    Strauch, Justus T.
    Seiffert, Moritz
    Bleiziffer, Sabine
    Bartko, Philipp Emanuel
    Zielinski, Marie
    Vijayan, Anjaly
    Bramlage, Peter
    Hengstenberg, Christian
    EUROPEAN JOURNAL OF CLINICAL INVESTIGATION, 2024, 54 (11)
  • [47] Eight-Row Multidetector Computed Tomography Coronary Angiography Evaluation of Significant Coronary Artery Disease in Patients with Severe Aortic Valve Stenosis
    Miia Holmström
    Mikko A. Sillanpää
    Markku Kupari
    Sari Kivistö
    Kirsi Lauerma
    The International Journal of Cardiovascular Imaging, 2006, 22 : 703 - 710
  • [48] Eight-row multidetector computed tomography coronary angiography evaluation of significant coronary artery disease in patients with severe aortic valve stenosis
    Holmstrom, Miia
    Sillanpaa, Mikko A.
    Kupari, Markku
    Kivisto, Sari
    Lauerma, Kirsi
    INTERNATIONAL JOURNAL OF CARDIOVASCULAR IMAGING, 2006, 22 (05) : 703 - 710
  • [49] Comparison of Accuracy of Aortic Root Annulus Assessment With Cardiac Magnetic Resonance Versus Echocardiography and Multidetector Computed Tomography in Patients Referred for Transcatheter Aortic Valve Implantation
    Pontone, Gianluca
    Andreini, Daniele
    Bartorelli, Antonio L.
    Bertella, Erika
    Mushtaq, Saima
    Gripari, Paola
    Loguercio, Monica
    Cortinovis, Sarah
    Baggiano, Andrea
    Conte, Edoardo
    Beltrama, Virginia
    Annoni, Andrea
    Formenti, Alberto
    Tamborini, Gloria
    Muratori, Manuela
    Guaricci, Andrea
    Alamanni, Francesco
    Ballerini, Giovanni
    Pepi, Mauro
    AMERICAN JOURNAL OF CARDIOLOGY, 2013, 112 (11) : 1790 - 1799
  • [50] Multislice computed tomography in the selection of candidates for transcatheter aortic valve implantation
    de Morais, Gustavo Pires
    Bettencourt, Nuno
    Silva, Guida
    Ferreira, Nuno
    Sousa, Olga
    Caeiro, Daniel
    Rocha, Joao
    Carvalho, Monica
    Leite, Daniel
    Braga, Pedro
    Fonseca, Conceicao
    Gama, Vasco
    REVISTA PORTUGUESA DE CARDIOLOGIA, 2011, 30 (09) : 717 - 726