Telemetric CPAP titration at home in patients with sleep apnea-hypopnea syndrome

被引:21
|
作者
Dellaca, Raffaele [2 ]
Montserrat, Josep M. [3 ,4 ]
Govoni, Leonardo [2 ]
Pedotti, Antonio [2 ]
Navajas, Daniel [1 ,4 ,5 ]
Farre, Ramon [1 ,4 ]
机构
[1] Univ Barcelona, Fac Med, IDIBAPS, Unitat Biofis & Bioengn, Barcelona 08036, Spain
[2] Politecn Milan, Dipartimento Bioingn, TBMLab, I-20133 Milan, Italy
[3] Hosp Clin Barcelona, IDIBAPS, Serv Pneumol, Sleep Lab, Barcelona, Spain
[4] CIBER Enfermedades Resp, Bunyola, Spain
[5] Inst Bioengn Catalunya, Barcelona, Spain
关键词
Home CPAP titration by telemetry; Telecare; Telemedicine; E-health; Obstructive sleep apnea; Point of care; POSITIVE AIRWAY PRESSURE; THERAPY; POLYSOMNOGRAPHY;
D O I
10.1016/j.sleep.2010.07.014
中图分类号
R74 [神经病学与精神病学];
学科分类号
摘要
Background: Home continuous positive airway pressure (CPAP) titration with automatic devices is not possible in a non-negligible percentage of patients with sleep apnea-hypopnea syndrome (SAHS). Objectives: To test the feasibility of a novel telemetric system for home CPAP titration. Methods: One-night home CPAP titration was carried out on 20 SAHS patients (56 +/- 3 years; BMI = 35 +/- 2 kg/m(2)). A telemetric unit, based on the conventional GPRS mobile phone network and connected to a commercial CPAP device, allowed the hospital technician to monitor flow, pressure and air leaks by remote control and titrate CPAP (elimination of apneas, hypopneas, flow limitation and snoring) in real time. After 1 week, a full hospital polysomnography was performed while the patient was subjected to the value of CPAP that was previously titrated at home via telemetry. Results: The home-titrated CPAP systematically improved patients' breathing: the apnea-hypopnea index and percentage of sleep time with arterial oxygen saturation below 90% were reduced from 58.1 +/- 5.1 to 3.8 +/- 0.6 events/h and from 19.8 +/- 1.1% to 4.4 +/- 0.7%, respectively. This CPAP value (9.15 +/- 0.47 cmH(2)O) was virtually the same as the pressure that optimized breathing during hospital polysomnography (9.20 +/- 0.41 cmH(2)O; mean difference: 0.02 cmH(2)O, limits of agreement: +/- 1.00 cmH(2)O). Conclusions: This pilot study shows that a simple telemetric system, requiring neither a special telemedicine network nor any infrastructure in the patient's home, made it possible to perform effective remote CPAP titration on SAHS patients. (C) 2010 Elsevier B.V. All rights reserved.
引用
收藏
页码:153 / 157
页数:5
相关论文
共 50 条
  • [21] Elevated Serum Liver Enzymes in Patients with Obstructive Sleep Apnea-hypopnea Syndrome
    Li Jie
    Zhang Yan-Lin
    Chen Rui
    Wang Yi
    Xiong Kang-Ping
    Huang Jun-Ying
    Han Fei
    Liu Chun-Feng
    中华医学杂志英文版, 2015, 128 (22) : 2983 - 2987
  • [22] Elevated Serum Liver Enzymes in Patients with Obstructive Sleep Apnea-hypopnea Syndrome
    Li, Jie
    Zhang, Yan-Lin
    Chen, Rui
    Wang, Yi
    Xiong, Kang-Ping
    Huang, Jun-Ying
    Han, Fei
    Liu, Chun-Feng
    CHINESE MEDICAL JOURNAL, 2015, 128 (22) : 2983 - 2987
  • [23] Obstructive sleep apnea-hypopnea syndrome patients with overweight and hypertension in a Japanese Workplace
    Okabayashi, Ken
    Kasahara, Etsuo
    Uchiyama, Hiroko
    Yokota, Kazuhiko
    Togashi, Yuki
    Kono, Chiyoko
    Yamada, Yoshihito
    Amano, Hiroko
    Yamaguchi, Tetsuo
    Kawamoto, Toshihiro
    Fujihara, Hiroaki
    Ueta, Yoichi
    JOURNAL OF OCCUPATIONAL HEALTH, 2007, 49 (02) : 117 - 124
  • [24] Sleep apnea-hypopnea syndrome and acute coronary syndrome - an association not to forget
    Areias, V.
    Romero, J.
    Cunha, K.
    Faria, R.
    Mimoso, J.
    Gomes, V.
    Brito, U.
    REVISTA PORTUGUESA DE PNEUMOLOGIA, 2012, 18 (01) : 22 - 28
  • [25] Sleep Apnea-Hypopnea Syndrome Without Excessive Daytime Sleepiness
    Hernandez Garcia, Concepcion
    ARCHIVOS DE BRONCONEUMOLOGIA, 2009, 45 (05): : 240 - 244
  • [26] Complications of obesity - Obesity and obstructive sleep apnea-hypopnea syndrome
    de Sousa, A. G. P.
    Cercato, C.
    Mancini, M. C.
    Halpern, A.
    OBESITY REVIEWS, 2008, 9 (04) : 340 - 354
  • [27] Accuracy of a novel auto-CPAP device to evaluate the residual apnea-hypopnea index in patients with obstructive sleep apnea
    Carlos Alberto Nigro
    Sergio González
    Anabella Arce
    María Rosario Aragone
    Luciana Nigro
    Sleep and Breathing, 2015, 19 : 569 - 578
  • [28] A randomized trial of auto-titrating CPAP and fixed CPAP in the treatment of obstructive sleep apnea-hypopnea
    Hussain, SF
    Love, L
    Burt, H
    Fleetham, JA
    RESPIRATORY MEDICINE, 2004, 98 (04) : 330 - 333
  • [29] Determinants of apnea-hypopnea index variability during home sleep testing
    Martinot, Jean-Benoit
    Le-Dong, Nhat-Nam
    Tamisier, Renaud
    Bailly, Sebastien
    Pepin, Jean-Louis
    SLEEP MEDICINE, 2023, 111 : 86 - 93
  • [30] Respiratory polygraphy with actigraphy in the diagnosis of sleep apnea-hypopnea syndrome
    Garcia-Diaz, Emilio
    Quintana-Gallego, Esther
    Ruiz, Aranzazu
    Carmona-Bernal, Carmen
    Sanchez-Armengol, Angeles
    Botebol-Benhamou, Georgina
    Capote, Francisco
    CHEST, 2007, 131 (03) : 725 - 732