Binocular Summation Improves Performance to Defocus-Induced Blur

被引:37
作者
Plainis, Sotiris [1 ]
Petratou, Dionysia
Giannakopoulou, Trisevgeni
Atchison, David A. [2 ,3 ]
Tsilimbaris, Miltiadis K. [4 ]
机构
[1] Univ Crete, Sch Hlth Sci, IVO, Iraklion, Greece
[2] Queensland Univ Technol, Inst Hlth & Biomed Innovat, Brisbane, Qld 4001, Australia
[3] Queensland Univ Technol, Sch Optometry, Brisbane, Qld 4001, Australia
[4] Univ Hosp Crete, Dept Ophthalmol, Iraklion, Greece
关键词
VISUAL-EVOKED-POTENTIALS; CONTRAST-SENSITIVITY FUNCTION; DEPTH-OF-FOCUS; SINUSOIDAL GRATINGS; OCULAR ABERRATIONS; NEGATIVE DEFOCUS; OPTICAL DEFOCUS; RETINAL IMAGE; HUMAN EYE; ACUITY;
D O I
10.1167/iovs.10-6545
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
PURPOSE. To assess whether there are any advantages of binocular over monocular vision under blur conditions. METHODS. The effect of defocus, induced by positive lenses, was measured on the pattern reversal visual evoked potential (VEP) and on visual acuity (VA). Monocular (dominant eye) and binocular VEPs were recorded from 13 volunteers (average age, 28 +/- 5 years; average spherical equivalent, -0.25 +/- 0.73 D) for defocus up to 2.00 D using positive powered lenses. VEPs were elicited using reversing 10 arcmin checks (4 reversals/s). The stimulus subtended a circular field of 7 degrees with 100% contrast and mean luminance 30 cd/m(2). VA was measured under the same conditions using ETDRS charts. All measurements were performed at 1 m viewing distance with best spectacle sphero-cylindrical correction and natural pupils. RESULTS. With binocular stimulation, amplitudes and implicit times of the P100 component of the VEPs were greater and shorter, respectively, in all cases than for monocular stimulation. Mean binocular enhancement ratio in the P100 amplitude was 2.1 in focus, increasing linearly with defocus to be 3.1 at + 2.00 D defocus. Mean peak latency was 2.9 ms shorter in focus with binocular than for monocular stimulation, with the difference increasing with defocus to 8.8 ms at +2.00 D. As for the VEP amplitude, VA was always better with binocular than with monocular vision, with the difference being greater for higher retinal blur. CONCLUSIONS. Both subjective and electrophysiological results show that binocular vision ameliorates the effect of defocus. The increased binocular facilitation observed with retinal blur may be due to the activation of a larger population of neurons at close-to-threshold detection under binocular stimulation. (Invest Ophthalmol Vis Sci. 2011; 52:2784-2789) DOI:10.1167/iovs.10-6545
引用
收藏
页码:2784 / 2789
页数:6
相关论文
共 68 条
[1]  
AMIGO G, 1978, INVEST OPHTH VIS SCI, V17, P910
[2]   Effect of localized defocus on detection thresholds for different sized targets in the fovea and periphery [J].
Anderson, RS ;
McDowell, RD ;
Ennis, FA .
ACTA OPHTHALMOLOGICA SCANDINAVICA, 2001, 79 (01) :60-63
[3]   CONTRAST CODING BY CELLS IN THE CATS STRIATE CORTEX - MONOCULAR VS BINOCULAR DETECTION [J].
ANZAI, A ;
BEARSE, MA ;
FREEMAN, RD ;
CAI, DQ .
VISUAL NEUROSCIENCE, 1995, 12 (01) :77-93
[4]   BINOCULARITY IN THE HUMAN VISUAL EVOKED-POTENTIAL - FACILITATION, SUMMATION AND SUPPRESSION [J].
APKARIAN, PA ;
NAKAYAMA, K ;
TYLER, CW .
ELECTROENCEPHALOGRAPHY AND CLINICAL NEUROPHYSIOLOGY, 1981, 51 (01) :32-48
[5]   MONOCULAR AND BINOCULAR DETECTION OF MOVING SINUSOIDAL GRATINGS [J].
ARDITI, AR ;
ANDERSON, PA ;
MOVSHON, JA .
VISION RESEARCH, 1981, 21 (03) :329-336
[6]  
ATCHISON DA, 1979, AM J OPTOM PHYS OPT, V56, P315
[7]   Predicting the effects of optical defocus on human contrast sensitivity [J].
Atchison, DA ;
Woods, RL ;
Bradley, A .
JOURNAL OF THE OPTICAL SOCIETY OF AMERICA A-OPTICS IMAGE SCIENCE AND VISION, 1998, 15 (09) :2536-2544
[8]   Noticeable, troublesome and objectionable limits of blur [J].
Atchison, DA ;
Fisher, SW ;
Pedersen, CA ;
Ridall, PG .
VISION RESEARCH, 2005, 45 (15) :1967-1974
[9]   Influence of Stiles-Crawford apodization on visual acuity [J].
Atchison, DA ;
Scott, DH ;
Strang, NC ;
Artal, P .
JOURNAL OF THE OPTICAL SOCIETY OF AMERICA A-OPTICS IMAGE SCIENCE AND VISION, 2002, 19 (06) :1073-1083
[10]   MEASUREMENT OF MONOCHROMATIC OCULAR ABERRATIONS OF HUMAN EYES AS A FUNCTION OF ACCOMMODATION BY THE HOWLAND ABERROSCOPE TECHNIQUE [J].
ATCHISON, DA ;
COLLINS, MJ ;
WILDSOET, CF ;
CHRISTENSEN, J ;
WATERWORTH, MD .
VISION RESEARCH, 1995, 35 (03) :313-323